CAUTION
CAUTION
* Warning: No servicing/maintenance while the ME equipment is
in use.
* The patient can measure data and change batteries under normal
circumstances and maintain the device and its accessories
according to the user manual.
* To avoid measurement errors, please avoid the condition of strong
electromagnetic field radiated interference signal or electrical fast
transient/burst signal.
* The blood pressure monitor and the cuff are suitable for use within
the patient environment. If you are allergic to polyester, nylon or
plastic, please don't use this device.
* During use, the patient will be in contact with the cuff. The materials
of the cuff have been tested and found to comply with requirements
of ISO 10993-5:2009 and ISO 10993-10:2010. It will not cause any
potential sensization or irritation reaction.
* If you experience discomfort during a measurement, such as pain
in the arm or other complaints, press the START/STOP button to
release the air immediately from the cuff. Loosen the cuff and
remove it from your arm.
* If the cuff pressure reaches 40 kPa (300 mmHg), the unit will
automatically deflate. Should the cuff not deflate when pressures
reaches 40 kPa (300 mmHg), detach the cuff from the arm and
press the START/STOP button to stop inflation.
* Before use, make sure the device functions safely and is in proper
working condition. Check the device, do not use the device if it is
damaged in any way. The continuous use of a damaged unit may
cause injury, improper results, or serious danger.
* Do not wash the cuff in a washing machine or dishwasher!
* The service life of the cuff may vary by the frequency of washing,
skin condition, and storage state. The typical service life is 10000
times.
* It is recommended that the performance should be checked every
2 years and after maintenance and repair, by retesting at least the
requirements in limits of the error of the cuff pressure indication
and air leakage (testing at least at 50mmHg and 200mmHg).
* Please dispose of ACCESSORIES, detachable parts, and the ME
EQUIPMENT according to the local guidelines.
* Manufacturer will make available on request circuit diagrams,
component part lists, descriptions, calibration instructions,etc.,
to assist to service personnel in parts repair.
* The operator shall not touch output of batteries and the patient
simultaneously.
* Cleaning :Dust environment may affect the performance of the unit.
Please use the soft cloth to clean the whole unit before and after
use. Don’t use any abrasive or volatile cleaners.
* The device doesn’t need to be calibrated within two years of
reliable service.
* If you have any problems with this device, such as setting up,
maintaining or using, please contact the SERVICE PERSONNEL
of Transtek. Don’t open or repair the device by yourself in the event
of malfunctions. The device must only be serviced, repaired and
opened by individuals at authorized sales/service centers.
* Please report to Transtek if any unexpected operation or events
occur.
* Keep the unit out of reach of infants, young children or pets to
avoid inhalation or swallowing of small parts. It is dangerous or
even fatal.