The warning signs and symbols are essential to ensure your correct and safe use of 

this product and protect you and others from injury. Please kindly find the meanings of the 

warning signs and symbols, which you may encounter in the label and user manual, as 

follows:

To ensure your safety as well as the service life of your scale, please avoid using 

the scale under the following circumstances:

Concurrent use of this device and implantable medical electronic instruments, e.g. 

Cardiac Pacemaker
Concurrent use of this device and wearable medical electronic instruments, e.g. 

electrocardiograph
Concurrent use of this device and other medical electronic instruments for life support, 

e.g. mechanical heart
Slippery floor such as tile floor
Jumping onto the platform immediately after bath or with wet hands
Near a cell phone or microwave oven

Avoid storage in the following locations:

Where there is water
Where the device may be exposed to extreme temperatures, humidity, moisture, direct 

sunlight, dust, or salt air
Where there is risk of shock or drop
Where you store chemicals or full of corrosive gases
Where in reach of the infants or children 

Safety and Usage Information

Your Scale and Its Environment

Safety Information

Safety Information

INDICATIONS FOR USE

The Transtek Body Fat Analyzer measures weight and uses bio-electrical impedance analysis 

(BIA) technology to estimate body fat, total body water percentage, bone mass, and muscle 

mass in generally healthy adults 18 years of age or older. 

It is intended for use in the home / domestic setting only. 

CONTRAINDICATIONS

1. This device is contraindicated for any female subject who may be suspected of, or is pregnant. 

Besides provided inaccurate readings, the affects of this device on the fetus are unknown. 

2. This device is contraindicated for any person who is connected to a wearable or implantable 

electronic device or instrument such as a pacemaker or defibrillator.

CAUTION

Symbol for “THE OPERATION 

GUIDE MUST BE READ”

Symbol for “MANUFACTURER”

Symbol for “ENVIRONMENT 

PROTECTION – Waste electrical 

products should not be disposed of with 

household waste. Please recycle where 

facilities exist. Check with your local 

authority or retailer for recycling advice”

Symbol for “TYPE BF APPLIED 

PARTS” 

The Bluetooth Combination Mark

Symbol for “SERIAL NUMBER”

Symbol for “DIRECT CURRENT”

Symbol for “INDOOR USE ONLY”

Symbol for “COMPLIES WITH FCC 

RULES”

Transtek’s Body Fat Analyzer GBF-1319-B offers you a seamless way to manage your health. 

Please be aware that this device is designed for adults’ self-measuring and self-monitoring body 

fat level. Any information provided by this device is in no way meant to treat, cure or prevent any 

disease or illness from happening.  This device should not be used by anyone who is acutely or 

chronically ill, suffering from a disease or taking medications that affect your water levels.  The 

accuracy of readings for these patients has not been verified.  Specific medical advice should be 

obtained from a physician.

GBF-1319-B is equipped with data transmission function. It may emit electromagnetic energy 

so as to perform its intended function. Nearby portable and mobile RF communications 

equipment can affect the performance of GBF-1319-B.

Portable and mobile RF communications equipment can affect the measuring accuracy of 

GBF-1319-B.

Kindly note that the use of accessories, transducers or cables other than those specified, with 

the exception of transducers and cables sold by the manufacturer as replacement parts for 

internal components, may result in increased EMISSIONS or decreased IMMUNITY of 

GBF-1319-B.

Be aware that misuse of electrical equipments can cause electric shock, burns, fire and other 

hazards. 

Warning that the GBF-1319-B should not be used adjacent to or stacked with other equipment.

Manufacturer will make available on request circuit diagrams, component parts list,etc.

WARNING:No modifications of this equipment is allowed.

During using the Analyzer, the patient will contact with the surface and the electrode of the 

Analyzer.

The device doesn’t need to be calibrated in two years lifetime.

Содержание GBF-1319-B

Страница 1: ...the manual well for further reference in case you have problems Thank you very much for selecting the Transtek Body Fat Analyzer GBF 1319 B GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO LTD Zone A 5 F In...

Страница 2: ...Your Scale Weight Only Operation Start Measuring First Measurement Daily Measurement Data Transmission Data Transmission Troubleshooting Error Prompt When Measuring When Data Transmitting Specificati...

Страница 3: ...THE OPERATION GUIDE MUST BE READ Symbol for MANUFACTURER Symbol for ENVIRONMENT PROTECTION Waste electrical products should not be disposed of with household waste Please recycle where facilities exi...

Страница 4: ...a flat hard surface Soft surface such as carpet will affect the performance of the scale Step onto the platform with bare feet Stand still and keep full contact with the electrodes until the measurem...

Страница 5: ...ercentage Foot Centimeter Age Male Male Athlete Female Female Athlete User ID Range from P1 to P8 LCD Display General Instructions Initial Start Up Insert the Batteries Open the battery door in the ba...

Страница 6: ...r Up With the advanced Bluetooth 4 0 technology applied the mobile or portable equipments which are equipped with Bluetooth function in line with BLE Technical Specifications established by global org...

Страница 7: ...o confirm Gender Athlete Mode An athlete is defined as an adult who is involved in intense physial activity of approximate 12 hours per week and who has a resting heart rate of approximately 60 beats...

Страница 8: ...automatically turn off after a few seconds Note The weight value won t be saved in the scale and won t be transmitted to the APP 1 Press the platform centre and remove your foot 2 0 0 will be display...

Страница 9: ...LCD will only display the weight data To find out the solutions please refer to Troubleshooting for more details STEP 1 Step on the platform barefooted when the LCD displays 0 0 15 14 First Measureme...

Страница 10: ...will disappear after successful data transmission and you may check your personal health data stored in your iPhone If the data transmission fails the symbol will remain The pending measurement data w...

Страница 11: ...e Solution Incorrect posture Abnormal measuring results Too high OR Too low OR Huge difference between two recent measurement Please step on the platform barefooted and stand still The device is locat...

Страница 12: ...h most similar data Please assign a User ID following the instruction in Set Up Your Profile The user fails to select the User ID from what the system found Please assign a User ID following the instr...

Страница 13: ...ent Temperature 10 to 40 Humidity 90 RH Storage Environment Temperature 20 to 55 Power Source 4 5V 3xAAA Batteries Turn on Method SENSE ON technology Auto OFF The scale will turn off after about 10s i...

Страница 14: ...rference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for...

Страница 15: ...pproximately 40 of total body weight Approximately 30 of total body weight Bone Mass Percentage Source Rico et al 1993 The average bone mass percentage for both men and women is between 4 to 5 EMC Gui...

Страница 16: ...MS that are not LIFE SUPPORTING Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test IEC 60601 TEST LEVEL Compliance level Electromagnetic environment guidance Conducted RF I...

Страница 17: ...distance according to frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz P V d 5 3 1 80 MHz to 800 MHz 800 MHz to 2 5 GHz 1 0 0 1 0 1 0 1 0 0 1 For transmitters r...

Отзывы: