TT100
·
77
·
Function
Section
Function
Code
Function
Definition
Setting Range
Mfr’s
Value
Change
Mul
tif
uncti
onal
Inp
ut an
d
O
utput
T
erm
in
al
s
F300
Relay token output
0: no function;
1: inverter fault protection;
2: over latent frequency 1;
3: over latent frequency 2;
4: free stop;
5: inverter running status 1;
6: DC braking;
7: acceleration/deceleration time
switchover;
8: Reaching the Set Count Value;
9: Reaching the Designated
Count Value;
10: inverter overload pre-alarm;
11: motor overload pre-alarm;
12: stalling;
13: Inverter is ready to run
14: inverter running status 2;
15: frequency arrival output;
16: Over heat pre-alarm
17: over latent current output
18: reserved
1
√
F301
DO1 token output
14
√
F302
DO2 token output
5
F303
DO1 output types
selection
0: level output : pulse output
0
√
F304~F306 Reserved
F307
Characteristic
frequency 1
F112
~
F111
10.00Hz
√
F308
Characteristic
frequency 2
F112
~
F111
50.00Hz
√
F309
Characteristic
frequency width
0
~
100
%
50
%
√
F310
Characteristic
current
0
~
1000A
Rated current
√
F311
Characteristic current
hysteretic loop width
0
~
100
%
10
%
√
F312
Frequency arrival
threshold
0.00
~
5.00Hz
0.00
√
F313
Count frequency
divisions
1
~
65000
1
√
F314
Set count values
F315
~
65000
1000
√
F315
Designated count
values
1
~
F314
500
√