TT100
·
76
·
R
un
ni
ng
C
o
ntr
ol
Mod
e
F203
Main frequency source X
0: Digital setting memory;
1: External analog AI1;
2: External analog AI2;
3: Pulse input given;
4: Stage speed control;
5: No memory by digital setting;
6:Keypad potentiometer;
7-8: Reserved;
9: PID adjusting;
10: MODBUS
0
╳
F204
Accessorial frequency
source Y
0: Digital setting memory;
1: External analog AI1;
2: External analog AI2;
3: Pulse input given;
4: Stage speed control;
5: PID adjusting; 6: Keypad
potentiometer AI3
0
╳
F205
Reference for selecting
accessorial frequency source Y
range
0: Relative to max frequency;
1: Relative to frequency X
0
╳
F206
Accessorial frequency Y range 0
~
100
%
100
╳
F207
Frequency source selecting
0: X; 1: X+Y;
2: X or Y (terminal switchover);
3: X or X+Y (terminal switchover);
4: Combination of stage speed and
analog 5: X-Y 6: X+(Y-50%)
0
╳
F208
Terminal
two-line/three-line
operation control
0:other type;
1:two-line type 1;
2: two-line type 2;
3: three-line operation control 1;
4: three-line operation control 2;
5: start/stop controlled by
direction pulse
0
╳
F209
Selecting the mode of
stopping the motor
0: stop by deceleration time;
1: free stop
0
╳
F210
Frequency display accuracy
0.01
~
2.00
0.01
√
F211
Speed of digital speed control
0.01
~
100.00Hz/S
5.00 Hz/S
√
F212
Direction memory
0: Invalid 1: Valid
0
√
F213
Selfstarting after repowered on 0: invalid; 1: valid
0
√
F214
Selfstarting after reset
0: invalid; 1: valid
0
√
F215
Selfstarting delay time
0.1
~
3000.0
60.0
√
F216
Times of selfstarting in case of
repeated faults
0
~
5
0
√
F217
Delay time for fault reset
0.0
~
10.0
3.0
√
F218
~
F219
Reserved
F220
Frequency memory after
power-down
0: invalid; 1: valid
0
√
F221
Reserved
F222
count memory selection
Setting range: 0: Invalid 1: Valid
0
√
F223~F230
Reserved