Appendix 5 Zoom Table of Function Code
Function
Section
Function
Code
Function
Definition
Setting Range
Mfr’s Value
Change
B
asic Par
ame
te
rs
F100
User‟s Password
0
~
9999
8
√
F102
Inverter‟s Rated Current (A)
1.0
~
800.0
Subject to inverter model
*
F103
Inverter Power (KW)
0.20
~
650.0
Subject to inverter model
*
F104
Inverter Power Code
100
~
400
Subject to inverter model
*
F105
Software Edition No.
1.00
~
10.00
Subject to inverter model
*
F107
Password Valid or Not
0: invalid; 1: valid
0
√
F108
Setting User‟s Password
0
~
9999
8
√
F109
Starting Frequency (Hz)
0.0
~
10.00Hz
0.00Hz
√
F110
Holding Time of Starting
Frequency (S)
0.0
~
10.0S
0.0
√
F111
Max Frequency (Hz)v
F113
~
650.0Hz
50.00Hz
√
F112
Min Frequency (Hz)
0.00Hz
~
F113
0.50Hz
√
F113
Target Frequency (Hz)
F111
~
F112
50.00Hz
√
F114
1
st
Acceleration Time
0.1
~
3000S
5.0S for 0.2
~
3.7KW
30.0S for 5.5
~
30KW
60.0S for above 37KW.
√
F115
1
st
Deceleration Time
0.1
~
3000S
√
F116
2
nd
Acceleration Time
0.1
~
3000S
8.0S for 0.2
~
3.7KW
50.0S for 5.5
~
30KW
90.0S for above 37KW.
√
F117
2
nd
Deceleration Time
0.1
~
3000S
√
F118
Turnover Frequency
15.00
~
650.0Hz
50.00
╳
F119
Reference
of
setting
accel/decel time
0: 0~50.00Hz
1: 0~max frequency
0
╳
F120
Forward/Reverse
Switchover dead-Time
0.0
~
3000S
0.0S
√
F121
Reserved
F122
Reverse Running Forbidden
0: invalid; 1: valid
0
╳
F123
Minus frequency is valid in
the mode of combined speed
control.
0
:
Invalid
;
1
:
valid
0
╳
F124
Jogging Frequency
F112
~
F111
5.00Hz
√
F125
Jogging Acceleration Time
0.1
~
3000S
0.2
~
3.7KW: 5.0S
5.5
~
30KW: 30.0S
Above37KW: 60.0S
√
F126
Jogging Deceleration Time
0.1
~
3000S
√