background image

EIS ENTRY-RX 

USER MANUAL

 

 

Page 3 

 

1

 

FOR YOUR SAFETY 

SWITCH ON SAFELY 

Do  not  switch  the  unit  on  when  use  of  wireless  phone  is  prohibited  or  when  it  may  cause 
interference or danger. 

INTERFERENCE 

All wireless phones and units may be susceptible to interference, which could affect performance. 

SWITCH OFF IN HOSPITALS 

Follow any restrictions. Switch the unit off near medical equipment. 

SWITCH OFF IN AIRCRAFT 

Follow any restrictions. Wireless devices can cause interference in aircraft. 

SWITCH OFF WHEN REFUELING 

Do not use the unit at a refueling point. Do not use near fuel or chemicals. 

SWITCH OFF NEAR BLASTING 

Follow any restrictions. Do not use the unit where blasting is in progress. 

USE SENSIBLY 

Use  only  in  the  normal  position  as  explained  in  the  product  documentation.  Do  not  touch  the 
antenna unnecessarily. 
 

Содержание EIS ENTRY-CR

Страница 1: ...EIS ENTRY RX USER MANUAL GSM REMOTE MOBILE SWITCH Programming Software v 1 4 2016 0816...

Страница 2: ......

Страница 3: ...START UP 6 5 LED INDICATION 7 6 CONNECTION DIAGRAM 8 7 EIS UNIT MANAGEMENT 9 8 EIS FUNCTIONS WITH PROGRAMMING INSTRUCTIONS 10 8 1 WEB SERVER LOG IN 10 8 2 WEB SERVER ADDING UNITS TO USER PROFILE 11 8...

Страница 4: ...er Main page select ADD mode 11 Figure 4 WEB Server Main page adding EIS units 12 Figure 5 WEB Server Unit management window 13 Figure 6 WEB Server Caller ID Access 14 Figure 7 WEB Server Output setti...

Страница 5: ...HOSPITALS Follow any restrictions Switch the unit off near medical equipment SWITCH OFF IN AIRCRAFT Follow any restrictions Wireless devices can cause interference in aircraft SWITCH OFF WHEN REFUELIN...

Страница 6: ...GSM switch system designed to ensure low cost simple to install use reliable and single box solution for remote managed switching application It is designed for unlimited range caller ID control Opti...

Страница 7: ...lt in 5 band GSM module Caller ID numbers control up to 100 caller ID numbers 1 output relay supported Programming with PC via USB to Mini USB cable connected to the unit Programming by WEB server Pro...

Страница 8: ...unit YOU MUST POWER THE EIS UNIT WITH THE POWER SUPPLY INCLUDED Do not power with any other power supply Power up the unit Wait until LED1 Green starts flashing This is set in around 30 45 seconds EI...

Страница 9: ...of the GSM signal from 1 to 5 LED flashes 1 is weak signal 5 is excellent signal Yellow LED LED3 Short flashing indicates that the GSM module is ON but it is not yet connected on the GSM network After...

Страница 10: ...nnection the EIS please take a look at connection diagram Figure 1 EIS Connection diagram IMPORTANT DO NOT USE Power out 12V AUX for electric lock driving Use separate power source for door electric l...

Страница 11: ...ifferent types of management programming Unit can be programmed directly by USB connection with the use of configuration software running on PC EIS Ware Unit can be programmed remotely by using WEB se...

Страница 12: ...ay WEB programming IMPORTANT SIM card in the EIS unit MUST have DATA PLAN to be able to use WEB programming 8 1 WEB SERVER LOG IN The web server can be find under the address http www eisware com Figu...

Страница 13: ...2 WEB SERVER ADDING UNITS TO USER PROFILE After login the user will be diverted to WEB server main window This page is used to add remove search for EIS units from the user s profile Select sign to s...

Страница 14: ...be on the card board box of the EIS Phone Number The telephone number of the SIM card in the EIS unit mandatory data GPRS settings Information needed to enable data connection between the server and...

Страница 15: ...e the configuration of the specific unit All changes made by the user are listed in the Change Log window By clicking Send to device button ALL changes are send to the unit User can revert all changes...

Страница 16: ...r ID Disabled deactivates caller ID function all numbers are restricted Caller ID for specific users will limit the caller ID function only to the numbers on the list Caller ID always ON will allow al...

Страница 17: ...nt will activate the output second Caller ID event will deactivate the output Time Pulse Output is time pulse mode After output is triggered it will be activated for the time defined in Output pulse d...

Страница 18: ...authorized call or SMS received If unauthorized call or SMS is received on the unit this event will activate output defined under this section Input 1 activate output If input 1 is activated this acti...

Страница 19: ...er User name Phone number and user name of the user that will be receiving notification messages Input1 If on input line 1 alarm condition is meet users with check boxes will receive alarm notificatio...

Страница 20: ...uthorized call the unit can notify user To enable notification SMS tick the check box in corresponding position Administration allowed to remote program by SMS By selection this option the user can Lo...

Страница 21: ...l User can select GSM module restart interval hours if needed Not advisable to use this parameter if not advised otherwise Self updating clock Parameter is used to allow unit to synchronize to real ti...

Страница 22: ......

Страница 23: ...TABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS EXPRESS OR IMPLIED WITH REGARD TO THE GOODS AND ACCEPTS THEM AS IS WHERE...

Отзывы: