8.6
ADMINISTRATION
Administration tab allows user to enable advanced settings: notification of unauthorized access,
periodic test messages, lock down of the unit…
Figure 8: WEB Server-Notification numbers
•
Phone number
,
User name:
Phone number and user name of the user that will be receiving
notification messages.
•
Input1:
If on input line 1 alarm condition is meet, users with check boxes will receive alarm
notification SMS.
Figure 9: WEB Server-Input alarm configuration
•
Periodic test:
User can receive periodic (keep-alive) SMS, tick the check box for the
appropriate user. Timer period is defined under parameter
Automatic periodic test SMS
, it
is definable in hours.