9 0
Egress Delay Warning &
Alarm
CODE 1 - FUNCTION MODE:
1---Momentary, No warning
2---Momentary, with warning
3---Momentary, with w
Alarm
4---Hold Contact, No warning
5---Hold Contact, with warning
6---Hold Contact, with warning
+ Alarm
CODE 2 - DELAY TIME:
0---No Delay
1-99 Seconds
90
CODE 1
CODE 2
#
Mode = 1
Momentary,
No warning
TIME = 0
No Delay
9 1
Door Opening Alarm &
TIMER
ALARM TIME:
0---No Alarm
1-999 Seconds
91
ALARM TIME
#
Time = 0,
No Alarm
9 4
Operation Mode & Wiegand
Output
MODES OF WIEGAND OUTPUT
0---Stand Alone Keypad-Valid
Codes & Cards Only
1---Reader-All Codes & Cards
2---Master Keypad-Valid
Codes & Cards only
3---Slave Keypad-Valid Codes
& Cards only
94
WIEGAND O/P MODE
#
Mode = 0
Keypad Mode
SYSTEM CODES
FUNCTION
CODE ENTRY
RESULTS
0 0 0 0
Factory Set Master Code
for User to set system in
programming Mode at the
first time.
THIS IS NOT A PERMANENT
S Y S T E M C O D E & I T I S
CHANGED IF A NEW MASTER
CODE IS PROGRAMMED.
0000 * *
OR
NEW MASTER CODE
* *
System in Programming Mode
9 9 9 9
REFRESH CODE -- Refresh the
system and set all its function
back to default values.
9999 #
All programmed data are cleared and
back to the default values except the
Master Code
8 0 8 0
DAP CODE-- Direct access
to programming mode. Valid
only in the power-up delay
period
8080 #
System in Programming Mode
0 9 9 9
USER PINs / Codes whole
group clearance Code - Key
in the Code to clear all the
users in the Location
LOCATIONS:
10--- User Group 1
20--- User Group 2
30--- User Group 3
40--- Vistor Group
41--- Duress Group 1
42--- Duress Group 2
43--- Duress Group 3
LOCATION NO.
0999 #
Whole group of users in the selected
location are cleared
* *
Exit Programming Code
**
The system back to normal opration
after programming
36
8 0
Door Forced Open Warning
& Time
FUNCTION MODE / TIME:
0---OFF
1-999 Seconds
80
FUNCTION / TIME
#
Mode = 0,
Door Forced
Open
Warning OFF
8 1
Propped-up Warning & Time
81
FUNCTION / TIME
#
Mode = 0,
Propped-up
Warning OFF