Transition Networks SMFE1039-200 Скачать руководство пользователя страница 8

CRMFE10xx-20x / SRMFE10xx-20x

14

24-hour Technical Support: 

1-800-260-1312

International: 

00-1-952-941-7600

Troubleshooting

1.

Is the PWR LED on either media converter illuminated?
NO 

Is the power adapter on the 

SRMFE10xx-20x

the proper type of

voltage and cycle frequency for an AC outlet? 

Is the power adapter properly installed in the 

SRMFE10xx-20x

media

converter and in the outlet?

Is the 

CRMFE10xx-20x

media converter inserted properly into the

chassis?

Is the power cord properly installed in the PointSystem™ chassis and
in the grounded AC outlet?

Does the grounded AC outlet provide power?

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.

YES 

Proceed to step 2.

2.

Is the LKC LED illuminated?
NO 

Check the twisted pair cables for proper connection.

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.

YES 

Proceed to step 3.

3.

Is the LKF LED illuminated?
NO

Check the fiber cables for proper connection.

Verify that the TX and RX cables on one media converter are
connected to the RX and TX ports, respectively, on the other media
converter.

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.

YES

Proceed to step 4.

4.

Is the RXC LED flashing?
NO

If there is no activity on the 100Base-TX port, proceed to step 5.

If there is activity on the 100Base-TX port, disconnect and reconnect
the 100Base-TX cable to restart the initialization process.

Restart the workstation to restart the initialization process.

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.

YES

Proceed to step 5.

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

15

Contact Us

Technical Support

Technical support is available 24 hours a day.
US and Canada:

1-800-260-1312

International:

00-1-952-941-7600

Transition Now

Chat live via the Web with Transition Networks Technical Support.
Log onto 

www.transition.com

and click the 

Transition Now

link.

Web-Based Seminars

Transition Networks provides seminars via live web-based training.
Log onto 

www.transition.com

and click the 

Learning Center

link.

E-Mail

Ask a question anytime by sending an e-mail to our technical support staff.

[email protected]

Address

Transition Networks
6475 City West Parkway
Minneapolis, MN 55344, USA
telephone:

952-941-7600

toll free:

800-526-9267

fax:

952-941-2322

Troubleshooting 

-- Continued

5.

Is the RXF LED flashing?
NO

If there is no activity on the 100Base-FX port, continue below

If there is activity on the 100Base-FX port, disconnect and reconnect
the 100Base-FX cable to restart the initialization process.

Verify that TX and RX cables on one media converter are connected
to RX and TX ports, respectively, on the other media converter.

Restart the workstation to restart the initialization process.

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.

YES

Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.

Содержание SMFE1039-200

Страница 1: ...4 miles CRMFE1015 200 SRMFE1015 200 RJ 45 100 m 328 ft SC 1310 nm single mode 40 km 24 8 miles CRMFE1016 200 SRMFE1016 200 RJ 45 100 m 328 ft SC 1310 nm single mode 60 km 32 3 miles CRMFE1017 200 SRMF...

Страница 2: ...00 m 328 ft SC 1550 nm TX 1310 nm RX 40 km 24 8 miles A CRMFE1029 202 or a SRMFE1029 202 is to be installed with either a CRMFE1029 203 or a SRMFE1029 203 where one is the local converter and the othe...

Страница 3: ...Mode H S H S Disable Autocross Enable Autocross D E D E techsupport transition com Click the Transition Now link for a live Web chat 5 Installation Continued Install the CRMFE10xx 20x Slide In Module...

Страница 4: ...tworks PointSystem chassis To power the SRMFE10xx 20x media converter AC The external power supply provided with this device is UL listed by the manufacturer of the power supply 1 Connect the barrel c...

Страница 5: ...ote media converters 4 1 Media Converter A Media Converter B Near End Device Far End Device original fault on the copper link media converter B disables the copper link media converter A disables the...

Страница 6: ...must meet or exceed IEEE 802 3 specifications Fiber Cable Bit Error Rate 10 9 Single mode fiber recommended 9 m Multimode fiber recommended 62 5 125 m Multimode fiber optional 100 140 85 140 50 125 m...

Страница 7: ...e pairs for the active pins e g blue white white blue orange white white orange etc Do not use flat or silver satin wire Crossover Cable 1 2 3 6 Straight Through Cable Twisted Pair 1 Twisted Pair 1 Tw...

Страница 8: ...TX cable to restart the initialization process Restart the workstation to restart the initialization process Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 YES Pro...

Страница 9: ...en verst sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen ein...

Отзывы: