Grounding the module

The SAPTF33XX-1XX modules come equipped with grounding lugs—
GROUNDING IS REQUIRED.  See Figure 5.

The installer must consult local and/or national electrical codes and regulations or
facility grounding requirements to determine required grounding of the module.
They require a grounding conductor wire terminated with a two-hole, compression-
type grounding connector. The 2-hole grounding connector and grounding wire

(copper only) 

is not included and must be provided by the customer/installer. See

Figure 6.

105

115

Grounding  Lugs

(Rear View )

Figure 5:  105 and 115 Grounding Lugs

Figure 6:  Grounding Connector and Copper Wire

2-Hole Grounding 

Connector

Copper Wire

Grounding wire size

The wire size of the Protective Earthing 

(ground)

conductor should be greater than

or equal to the wire size of the power source conductors. The power-source
conductor wire size is installation dependent and sized to accommodate acceptable
IR losses between the power source and the device terminal block. The device
terminal block accommodates #6 wire lugs. A #6 wire lug typically terminates #16 -
#20 wire, with #18 being the most common.

9

[email protected], click the “Transition Now” link for a live Web chat.

Installation 

— Continued

Grounding the module — continued

The electrical conducting path from the module must:

Flow via the grounding lugs to the common bonding network (CBN) as
required.

Be of sufficiently low impedance to conduct fault currents likely to be imposed
on the module.

Enable proper operation of any over-current protection devices. 

The conductor must be fastened to the grounding lugs with the enclosed anti-rotation
star washers and lug-nut fasteners. The applied torque required for proper connection
with the lug-nut fasteners is specified by the connector’s manufacturer. 

To properly ground the SAPTF33xx-1xx module:

1.

Obtain one (1) grounding conductor

(#12 AWG copper wire or larger is

suggested; however, the installer must consult local and/or national electrical
codes and regulations or facility grounding requirements to determine required
conductor size.) 

and a 2-hole compression-type grounding connector.  

2.

Remove the two Kepnuts.

3.

Attach the grounding conductor to the module by placing the two-hole
connector onto the grounding lugs and fasten with the attached Kepnuts at the
proper torque

(per the manufacturer’s specification)

.

4.

Attach the opposite end of the grounding conductor to the common bonding
network (CBN) as required.

Kepnuts

2-Hole Ground

Connector

Grounding Lugs

Figure 7:  Model 105 Grounding Feature 

Содержание SAPTF33-1 Series

Страница 1: ...own Two units are required to implement an end to end system An RJ 11C female connector provides the electrical interface between the SAPTF33xx 1xx and the terminal equipment or telephone line wall ja...

Страница 2: ...m 3 1 miles SC connector 1310 nm single mode 60 km 37 8 miles SAPTF3317 105 RJ 11C connector 5 km 3 1 miles SC connector 1550 nm single mode 80 km 49 7 miles 3 techsupport transition com click the Tra...

Страница 3: ...miles SAPTF3317 115 RJ 11C connector 5 km 3 1 miles SC connector 1550 nm single mode 80 km 49 7 miles Typical maximum cable distance Actual distance is dependent upon the physical characteristics of t...

Страница 4: ...pins 1 and 2 of header JP1 on the 115 only is set at the factory and must be in place for proper operation Using small needle nosed pliers or similar tool to move the jumper to the desired position S...

Страница 5: ...g the most common 9 techsupport transition com click the Transition Now link for a live Web chat Installation Continued Grounding the module continued The electrical conducting path from the module mu...

Страница 6: ...upport transition com Click the Transition Now link for a live Web chat Installation Continued Installing cables standard configuration continued Install copper cable 1 Locate a copper cable with male...

Страница 7: ...ephone or FXO 12 SAPTF33xx 1xx 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Installation Continued Installing cables automatic ring down configuration Note Both Unit B modu...

Страница 8: ...g the illuminated LED power indicator light DC Consult the user s guide for the Transition Networks SPS2460 xx DC external power supply for powering the module Figure 13 Power Connector Power Connecto...

Страница 9: ...flow 4 The CO senses in DC current level and connects the call to the telephone line 5 Communication can now begin 17 techsupport transition com click the Transition Now link for a live Web chat Cable...

Страница 10: ...dards and complies with 21 CFR1040 10 and 21CFR1040 11 19 techsupport transition com click the Transition Now link for a live Web chat Technical Specification These specifications are for the model SA...

Страница 11: ...evices that may be connected to a telephone line Excessive ringer loading on a telephone line may result in the devices not ringing properly in response to an incoming call In most but not in all area...

Страница 12: ...e nombre maximal de terminaux qui peuvent tre raccord s une interface t l phonique La terminaison d une interface peut consister en une combinaison quelconque de dispositifs la seule condition que la...

Страница 13: ...not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas...

Отзывы: