Transition Networks SAPTF33-1 Series Скачать руководство пользователя страница 13

Trademark Notice

All registered trademarks and trademarks are the property of their respective owners.

Copyright Restrictions

© 2010 Transition Networks.
All rights reserved.  No part of this work may be reproduced or used in any form or by any means -
graphic, electronic, or mechanical - without written permission from Transition Networks. 

Printed

in the U.S.A.

33441.B

Compliance Information

FCC regulations

This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC rules.  These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.  This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at the user's own expense.

Canadian regulations

This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out
on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables
aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage
radioélectrique édicté par le ministère des Communications du Canada.

Warning

This is a Class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.

Achtung !

Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses
Gerätes Rundfunkstörungen auftreten.  In diesem Fäll ist der Benutzer für  Gegenmaßnahmen
verantwortlich.

Attention !

Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des
interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques
appropriées.

In accordance with European Union Directive 2002/96/EC of the European
Parliament and of the Council of 27 January 2003, Transition Networks will accept
post usage returns of this product for proper disposal. The contact information for
this activity can be found in the 'Contact Us' portion of this document. 

Содержание SAPTF33-1 Series

Страница 1: ...own Two units are required to implement an end to end system An RJ 11C female connector provides the electrical interface between the SAPTF33xx 1xx and the terminal equipment or telephone line wall ja...

Страница 2: ...m 3 1 miles SC connector 1310 nm single mode 60 km 37 8 miles SAPTF3317 105 RJ 11C connector 5 km 3 1 miles SC connector 1550 nm single mode 80 km 49 7 miles 3 techsupport transition com click the Tra...

Страница 3: ...miles SAPTF3317 115 RJ 11C connector 5 km 3 1 miles SC connector 1550 nm single mode 80 km 49 7 miles Typical maximum cable distance Actual distance is dependent upon the physical characteristics of t...

Страница 4: ...pins 1 and 2 of header JP1 on the 115 only is set at the factory and must be in place for proper operation Using small needle nosed pliers or similar tool to move the jumper to the desired position S...

Страница 5: ...g the most common 9 techsupport transition com click the Transition Now link for a live Web chat Installation Continued Grounding the module continued The electrical conducting path from the module mu...

Страница 6: ...upport transition com Click the Transition Now link for a live Web chat Installation Continued Installing cables standard configuration continued Install copper cable 1 Locate a copper cable with male...

Страница 7: ...ephone or FXO 12 SAPTF33xx 1xx 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Installation Continued Installing cables automatic ring down configuration Note Both Unit B modu...

Страница 8: ...g the illuminated LED power indicator light DC Consult the user s guide for the Transition Networks SPS2460 xx DC external power supply for powering the module Figure 13 Power Connector Power Connecto...

Страница 9: ...flow 4 The CO senses in DC current level and connects the call to the telephone line 5 Communication can now begin 17 techsupport transition com click the Transition Now link for a live Web chat Cable...

Страница 10: ...dards and complies with 21 CFR1040 10 and 21CFR1040 11 19 techsupport transition com click the Transition Now link for a live Web chat Technical Specification These specifications are for the model SA...

Страница 11: ...evices that may be connected to a telephone line Excessive ringer loading on a telephone line may result in the devices not ringing properly in response to an incoming call In most but not in all area...

Страница 12: ...e nombre maximal de terminaux qui peuvent tre raccord s une interface t l phonique La terminaison d une interface peut consister en une combinaison quelconque de dispositifs la seule condition que la...

Страница 13: ...not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas...

Отзывы: