Technical Specifications 

 

Standards

 

Compliance

 

IEEE

 

802.3,

 

2006

 

Edition;

 

IEEE

 

802.3z;

 

IEEE

 

802.3x;

 

IEEE

 

802.1Q,

  

IEEE

 

802.3ad;

 

Class

 

1

 

Laser

 

Product.

 

Complies

 

with

 

21CFR(J).

 

Data

 

rate

 

1000Mbps

 

fiber

 

media

 

Emissions

 

Compliance

  

EN55022

 

Class

 

B,

 

CE

 

Immunity

 

Compliance

 

EN55024

 

Safety

 

Compliance

 

U.L.

 

listed,

 

CE

 

mark,

 

ROHS

 

Power

 

Consumption

 

2.0W

 

PCI

E

  

/

 

~1

 

watt

 

Power

 

Source

 

PCI

E

 

slot

 

Bus

 

Slot

 

PCIe

 

2.1

 

x1

 

compliant

 

Weight

   

0.55

 

lbs.

 

(0.25

 

kg)

 

Power

 

Requirements

 

Fixed

 

Optic

 

Versions:

  

0.87

 

Watts

 

(approximately),

 

264

 

mA

 

@

 

3.3

 

VDC

 

SFP

 

Version:

 

1.66

 

Watts

 

(approximately),

 

503mA

 

x

 

3.3

 

VDC

 

Operating

 

Temperature

 

0

 

to

 

+50

 

degrees

 

C

 

Storage

 

Temperature

 

15

 

to

 

+65

 

degrees

 

C

  

(+5

°F

 

to

 

+149°F

)

  

Operating

 

Humidity

 

5%

 

to

 

95%

 

(non

condensing)

 

Altitude

 

0

10,000

 

feet

 

MTBF

 

(

SC,

 

–LC,

 

and

 ‐

ST)

 

N

GXE

xx

02

 

@

 

25C

 

=

 

1246,176

 

Bellcore7

 

V5.0

 

Hours

 

N

GXE

xx

02

 

@

 

40C

 

=

 

658,260

 

Bellcore7

 

V5.0

 

Hours

 

MTBF

 

(

SFP)

 

N

GXE

SFP

02

 

@

 

25C

 

=

 

1246,176

 

Bellcore7

 

V5.0

 

(Hours)

 

N

GXE

SFP

02

 

@

 

40C

 

=

 

658,260

 

Bellcore7

 

V5.0

 

(Hours)

 

Warranty

 

Lifetime

 

WARNING

:

 

Visible

 

and

 

invisible

 

laser

 

radiation

 

when

 

open:

 

DO

 

NOT

 

stare

 

into

 

the

 

beam

 

or

 

view

 

directly

 

with

 

optical

 

instruments.

 

Failure

 

to

 

observe

 

this

 

warning

 

could

 

result

 

in

 

damage

 

to

 

your

 

vision

 

or

 

blindness.

 

CAUTION

:

 

Use

 

of

 

controls,

 

adjustments,

 

or

 

the

 

performance

 

of

 

procedures

 

other

 

than

 

those

 

specified

 

herein

 

may

 

result

 

in

 

hazardous

 

radiation

 

exposure.

 

FCC

 

Regulations

:

 

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

class

 

B

 

computing

 

device

 

pursuant

 

to

 

Subpart

 

J

 

of

 

part

 

15

 

of

 

FCC

 

Rules,

 

which

 

are

 

designed

 

to

 

provide

 

reasonable

 

protection

 

against

 

such

 

interference

 

when

 

operated

 

in

 

a

 

commercial

 

environment.

 

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

protection

 

requirements

 

of

 

European

 

Emission

 

Standard

 

EN55022/EN61000

3

 

and

 

the

 

Generic

 

European

 

Immunity

 

Standard

 

EN55024.

 

 

Содержание N-GXE Series

Страница 1: ...ailover support Supports IPv4 and IPv6 Supports TCP segmentation offload up to 256 Kb Contents Contents 1 Introduction 2 Ordering Information 2 Application Example 3 Installation 3 Package Contents 3...

Страница 2: ...nd Wake on LAN the adapter provides enhanced performance flexible configuration and secure networking for users in a standard based environment An LED indicator on the bracket displays link status act...

Страница 3: ...ystem Requirements PCI Express enabled computer system with available PCI Express slot Supported OS ACPI aware OS for support of remote wake up WOL The latest BIOS on your computer One open PCI Expres...

Страница 4: ...ets 1 Ground yourself to dissipate any static charge 2 Remove the two screws securing the standard bracket to the back side of the NIC 3 Slide the standard bracket away from the NIC 4 Slide the low pr...

Страница 5: ...g and disconnect the PC and then wait for 15 20 seconds before plugging the NIC into the PC When removing the NIC unplug the Ethernet cable before removing the PC cover To install the N GXE NIC do the...

Страница 6: ...sconnect all cables before removing or installing an SFP module 3 Insert the SFP fully into the cage 4 Position the LC fiber cable at the SFP 5 Insert the LC fiber cable end completely into the SFP 6...

Страница 7: ...Device Manager from the left window pane 3 In Device Manager under Network Adapters you should see the NIC listed as I210 Gigabit Fiber Connection 4 Optional at this point you can set up advanced fea...

Страница 8: ...default when you install the device drivers Intel PROSet for Windows Device Manager is installed with the same process used to install drivers You must have administrator rights to install or use Inte...

Страница 9: ...download directory 3 Click Install Drivers and Software and follow the instructions in the install wizard Intel R PROSet functionality is integrated with the Windows Device Manager To configure Intel...

Страница 10: ...ip the driver to your computer e g for Windows 7 64 bit OS the driver should be unzipped in the C WINDOWS7 64 directory 3 Shut down the computer and then remove the N GXE NIC from the computer 4 Run W...

Страница 11: ...er from the left window pane 3 In Device Manager under Network Adapters you should see the NIC listed as Intel I210 Gigabit Fiber Network Connection 4 Navigate to the required tab e g the Driver tab 5...

Страница 12: ...gement APM Support o Advanced Configuration and Power Interface ACPI Specification v2 0c o Magic Packet Wake up enable Jumbo frames support up to 9014 bytes IPv4 and IPv6 o IPv4 checksum offloading TC...

Страница 13: ...tware solution allowing a computer to be woken up remotely Being able to power up a remote computer lets an administrator perform off hours maintenance at a remote site without having to send a techni...

Страница 14: ...s calculated by the NIC instead of the system CPU This reduces CPU load and can improve system performance in high traffic environments There is typically no need to disable checksum offload Fragmente...

Страница 15: ...the VLAN may have a momentary loss of connectivity A VLAN cannot be removed if a virtual NIC is bound to it The VLANs tab includes Name column Displays the name assigned to the VLAN ID Column Displays...

Страница 16: ...r optic transmitter power min 9 5 dBm max 4 0 dBm Fiber optic receiver sensitivity min 17 0 dBm max 17 0 dBm Link budget 8 0 dB N GXE LC 02 850 nm multimode Fiber optic transmitter power min 9 5 dBm m...

Страница 17: ...XE xx 02 25C 1246 176 Bellcore7 V5 0 Hours N GXE xx 02 40C 658 260 Bellcore7 V5 0 Hours MTBF SFP N GXE SFP 02 25C 1246 176 Bellcore7 V5 0 Hours N GXE SFP 02 40C 658 260 Bellcore7 V5 0 Hours Warranty L...

Страница 18: ...Transition Networks N GXE xx 02 User Guide 33748 Rev A https www transition com Page 18 of 26 Dimensions Standard Bracket...

Страница 19: ...Transition Networks N GXE xx 02 User Guide 33748 Rev A https www transition com Page 19 of 26 LP Bracket...

Страница 20: ...OK Off link fail Flash link OK activity Green Full duplex Yellow Half duplex L A Link Activity SFP Version On Communication link Off Link Fail Flash Link OK and Activity Green 1 Gbps Yellow 100 Mbps I...

Страница 21: ...hat is slowing down your system Processor and memory Check your performance monitoring programs and see if traffic is being affected by your processor speed available memory or other processes Transmi...

Страница 22: ...her slot 8 Use the troubleshooting procedures in the computer s user guide 9 Use the troubleshooting procedures on the PXE Boot Loader webpage as required 10 Use the troubleshooting procedures on the...

Страница 23: ...______________ PC s Icon Tray indication ________________________________________________________________ Connected Device s ___________________________________________________________________ Cable t...

Страница 24: ...Device Label Contact Us Technical Support Technical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Main Office tel 1 952 941 7600 toll free 1 800 526...

Страница 25: ...des Communications du Canada European Regulations Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse B In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten In diesem F...

Страница 26: ...91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformit t Record of Revisions Rev Dat...

Отзывы: