background image

Transition

 

Networks

 

 

N

GXE

xx

02

 

User

 

Guide

 

33748

 

Rev.

 

A

 

https://www.transition.com/

 

Page

 

14

 

of

 

26

 

Jumbo Frames 

Jumbo

 

Frames

 

are

 

Ethernet

 

frames

 

larger

 

than

 

1518

 

bytes.

 

Jumbo

 

Frames

 

can

 

be

 

used

 

to

 

reduce

 

server

 

CPU

 

utilization

 

and

 

increase

 

throughput.

 

Note,

 

however,

 

that

 

using

 

Jumbo

 

Frames

 

may

 

introduce

 

latency.

 

Also,

 

end

to

end

 

network

 

devices

 

must

 

support

 

Jumbo

 

Frames,

 

otherwise

 

packets

 

will

 

be

 

dropped.

  

Jumbo

 

Frames

 

also

 

require

 

compatible

 

switch

 

connections

 

that

 

can

 

forward

 

Jumbo

 

Frames;

 

see

 

the

 

switch

 

user

 

guide

 

or

 

contact

 

your

 

network

 

administrator.

 

Jumbo

 

Frames

 

supported

 

protocols

 

include

 

TCP

 

and

 

UDP

 

only.

 

The

 

N

GXE

xx

02

 

supports

 

Jumbo

 

Frames

 

up

 

to

 

9014

 

bytes.

 

TCP Segmentation Offload (up to 256 Kb) 

This

 

networking

 

technology

 

helps

 

transfer

 

the

 

workload

 

from

 

the

 

CPU

 

to

 

a

 

network

 

adapter

 

during

 

network

 

data

 

transfer.

 

In

 

Windows

 

Server

 

2008,

 

TCP

 

Segmentation

 

Offload

 

enables

 

the

 

Windows

 

networking

 

subsystem

 

to

 

offload

 

the

 

processing

 

of

 

a

 

TCP/IP

 

connection

 

to

 

a

 

network

 

adapter

 

that

 

includes

 

special

 

support

 

for

 

TCP/IP

 

offload

 

processing.

 

TCP

 

Segmentation

 

Offload

 

is

 

available

 

in

 

all

 

versions

 

of

 

Windows

 

Server

 

2008

 

and

 

Windows

 

Vista.

 

TCP

 

Segmentation

 

Offload

 

will

 

work

 

only

 

if

 

it

 

is

 

enabled

 

in

 

both

 

locations.

 

IPv6 support for IP/TCP and IP/UDP RX Checksum Offload 

When

 

enabled,

 

the

 

checksum

 

is

 

calculated

 

by

 

the

 

NIC

 

instead

 

of

 

the

 

system

 

CPU.

 

This

 

reduces

 

CPU

 

load

 

and

 

can

 

improve

 

system

 

performance

 

in

 

high

traffic

 

environments.

 

There

 

is

 

typically

 

no

 

need

 

to

 

disable

 

checksum

 

offload.

 

Fragmented UDP Checksum Offload for Packet Reassembly 

When

 

enabled,

 

the

 

checksum

 

is

 

calculated

 

by

 

the

 

NIC

 

instead

 

of

 

the

 

system

 

CPU.

 

This

 

reduces

 

CPU

 

load

 

and

 

can

 

improve

 

system

 

performance

 

in

 

high

traffic

 

environments.

 

There

 

is

 

typically

 

no

 

need

 

to

 

disable

 

checksum

 

offload.

 

PXE Boot 

This

 

specification

 

describes

 

a

 

standardized

 

client

server

 

environment

 

that

 

boots

 

a

 

software

 

assembly,

 

retrieved

 

from

 

a

 

network,

 

on

 

PXE

enabled

 

clients.

 

On

 

the

 

client

 

side

 

it

 

requires

 

only

 

a

 

PXE

capable

 

NIC,

 

and

 

uses

 

a

 

small

 

set

 

of

 

industry

standard

 

network

 

protocols.

 

UEFI Boot 

The

 

Unified

 

Extensible

 

Firmware

 

Interface

 

(UEFI)

 

specification

 

defines

 

a

 

software

 

interface

 

between

 

an

 

OS

 

and

 

platform

 

firmware.

 

UEFI

 

replaces

 

the

 

BIOS

 

firmware

 

interface

 

originally

 

present

 

in

 

all

 

IBM

 

PC

compatibles.

 

Most

 

UEFI

 

firmware

 

implementations

 

provide

 

legacy

 

support

 

for

 

BIOS

 

services.

 

The

 

Unified

 

EFI

 

Forum

 

is

 

the

 

industry

 

body

 

that

 

manages

 

the

 

UEFI

 

specification.

 

Smart Load Balancing (SLB) and Failover 

In

 

a

 

Smart

 

Load

 

Balance

 

and

 

Failover

 

team,

 

a

 

standby

 

member

 

handles

 

the

 

traffic

 

if

 

all

 

of

 

the

 

load

 

balance

 

members

 

fail

 

(considered

 

a

 

failover

 

event).

 

All

 

load

 

balance

 

members

 

must

 

fail

 

before

 

the

 

standby

 

member

 

takes

 

over.

 

When

 

one

 

or

 

more

 

of

 

the

 

load

 

balance

 

members

 

is

 

restored

 

(fallback),

 

the

 

restored

 

team

 

member(s),

 

resume

 

handling

 

traffic.

 

Содержание N-GXE Series

Страница 1: ...ailover support Supports IPv4 and IPv6 Supports TCP segmentation offload up to 256 Kb Contents Contents 1 Introduction 2 Ordering Information 2 Application Example 3 Installation 3 Package Contents 3...

Страница 2: ...nd Wake on LAN the adapter provides enhanced performance flexible configuration and secure networking for users in a standard based environment An LED indicator on the bracket displays link status act...

Страница 3: ...ystem Requirements PCI Express enabled computer system with available PCI Express slot Supported OS ACPI aware OS for support of remote wake up WOL The latest BIOS on your computer One open PCI Expres...

Страница 4: ...ets 1 Ground yourself to dissipate any static charge 2 Remove the two screws securing the standard bracket to the back side of the NIC 3 Slide the standard bracket away from the NIC 4 Slide the low pr...

Страница 5: ...g and disconnect the PC and then wait for 15 20 seconds before plugging the NIC into the PC When removing the NIC unplug the Ethernet cable before removing the PC cover To install the N GXE NIC do the...

Страница 6: ...sconnect all cables before removing or installing an SFP module 3 Insert the SFP fully into the cage 4 Position the LC fiber cable at the SFP 5 Insert the LC fiber cable end completely into the SFP 6...

Страница 7: ...Device Manager from the left window pane 3 In Device Manager under Network Adapters you should see the NIC listed as I210 Gigabit Fiber Connection 4 Optional at this point you can set up advanced fea...

Страница 8: ...default when you install the device drivers Intel PROSet for Windows Device Manager is installed with the same process used to install drivers You must have administrator rights to install or use Inte...

Страница 9: ...download directory 3 Click Install Drivers and Software and follow the instructions in the install wizard Intel R PROSet functionality is integrated with the Windows Device Manager To configure Intel...

Страница 10: ...ip the driver to your computer e g for Windows 7 64 bit OS the driver should be unzipped in the C WINDOWS7 64 directory 3 Shut down the computer and then remove the N GXE NIC from the computer 4 Run W...

Страница 11: ...er from the left window pane 3 In Device Manager under Network Adapters you should see the NIC listed as Intel I210 Gigabit Fiber Network Connection 4 Navigate to the required tab e g the Driver tab 5...

Страница 12: ...gement APM Support o Advanced Configuration and Power Interface ACPI Specification v2 0c o Magic Packet Wake up enable Jumbo frames support up to 9014 bytes IPv4 and IPv6 o IPv4 checksum offloading TC...

Страница 13: ...tware solution allowing a computer to be woken up remotely Being able to power up a remote computer lets an administrator perform off hours maintenance at a remote site without having to send a techni...

Страница 14: ...s calculated by the NIC instead of the system CPU This reduces CPU load and can improve system performance in high traffic environments There is typically no need to disable checksum offload Fragmente...

Страница 15: ...the VLAN may have a momentary loss of connectivity A VLAN cannot be removed if a virtual NIC is bound to it The VLANs tab includes Name column Displays the name assigned to the VLAN ID Column Displays...

Страница 16: ...r optic transmitter power min 9 5 dBm max 4 0 dBm Fiber optic receiver sensitivity min 17 0 dBm max 17 0 dBm Link budget 8 0 dB N GXE LC 02 850 nm multimode Fiber optic transmitter power min 9 5 dBm m...

Страница 17: ...XE xx 02 25C 1246 176 Bellcore7 V5 0 Hours N GXE xx 02 40C 658 260 Bellcore7 V5 0 Hours MTBF SFP N GXE SFP 02 25C 1246 176 Bellcore7 V5 0 Hours N GXE SFP 02 40C 658 260 Bellcore7 V5 0 Hours Warranty L...

Страница 18: ...Transition Networks N GXE xx 02 User Guide 33748 Rev A https www transition com Page 18 of 26 Dimensions Standard Bracket...

Страница 19: ...Transition Networks N GXE xx 02 User Guide 33748 Rev A https www transition com Page 19 of 26 LP Bracket...

Страница 20: ...OK Off link fail Flash link OK activity Green Full duplex Yellow Half duplex L A Link Activity SFP Version On Communication link Off Link Fail Flash Link OK and Activity Green 1 Gbps Yellow 100 Mbps I...

Страница 21: ...hat is slowing down your system Processor and memory Check your performance monitoring programs and see if traffic is being affected by your processor speed available memory or other processes Transmi...

Страница 22: ...her slot 8 Use the troubleshooting procedures in the computer s user guide 9 Use the troubleshooting procedures on the PXE Boot Loader webpage as required 10 Use the troubleshooting procedures on the...

Страница 23: ...______________ PC s Icon Tray indication ________________________________________________________________ Connected Device s ___________________________________________________________________ Cable t...

Страница 24: ...Device Label Contact Us Technical Support Technical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Main Office tel 1 952 941 7600 toll free 1 800 526...

Страница 25: ...des Communications du Canada European Regulations Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse B In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten In diesem F...

Страница 26: ...91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformit t Record of Revisions Rev Dat...

Отзывы: