FAULT ISOLATION and CORRECTION

If the E-FL-HB-0x00 fails, isolate and correct the fault by determining the
answers to the following questions and then taking the indicated action:

1.

Is the P(o)W(e)R LED on the E-FL-HB-0x00 illuminated?
NO

Is the power cord properly installed in the E-FL-HB-0x00 and in the
grounded AC outlet?

Does the grounded AC outlet provide power?

Contact Technical Support: (800) 260-1312.

YES

Continue at step 2.

2.

Is a backbone uplink adapter installed at E-FL-HB-0x00 back? 
NO

Continue at step 7.

YES

Continue at step 3.

3.

Is the B(ack)B(one) STAT(us) LED illuminated continuously?
YES

Continue at step 7.

NO

Continue at step 4.

4.

Does the B(ack)B(one) STAT(us) LED continuously blink ONCE?
YES

Ensure that backbone uplink adapter is firmly connected.

Check backbone uplink cables for proper cabling and connection(s).

Ensure that device at remote end of network link is powered.

Contact Technical Support: (800) 260-1312.

NO

Continue at step 5.

5.

Does the B(ack)B(one) STAT(us) LED continuously blink TWICE?
YES

If the AUI backbone adapter plate is installed, check the installed
transceiver or the drop cable connections.

If the BNC backbone adapter plate is installed, ensure that coaxial
cable connections are secure and that daisy-chained cable is
terminated at both ends. (See page 7.)

If the fiber backbone adapter plate is installed and LINKAlert™ is
NOT enabled, the port is partitioned; investigate the device at the
far end of the link..

If the fiber backbone adapter plate is installed and LINKAlert™ IS
enabled, determine and correct the cause of the Far End Fault.

Contact Technical Support: (800) 260-1312.

NO

Continue at step 6.

Install E-FL-HB-0x00 at Site

WARNING: During the site installation, handle the E-FL-HB-0x00 in such a
way that the E-FL-HB-0x00 does not fall. Failure to observe this warning
could result in injury to personnel and/or equipment damage.

NOTE: If E-FL-HB-0x00 is shipped with brackets installed, proceed to step 2.

To install the E-FL-HB-0x00 in 19-inch rack cabinet:

1.

Remove and retain two (2) screws located at front left side and front
right side of E-FL-HB-0x00 chassis. Install right and left front
brackets (provided) on chassis by installing two (2) retained screws
through each bracket into chassis.

2.

Carefully align E-FL-HB-0x00 between 19-inch rack mounting rails.

3.

Install E-FL-HB-0x00 by installing two (2) screws through right front
bracket into rack and two (2) screws through left front bracket into
rack, using clip nuts (NOT provided) to secure, if necessary.

To install the E-FL-HB-0x00 on table or other flat surface:

NOTE: Rubber feet are provided.

1.

Carefully turn E-FL-HB-0x00 to side.

2.

Install four (4) rubber feet:

Separate rubber feet.

Remove
protective paper
from adhesive
surface on rubber
foot.

Position and secure each rubber foot as shown.

3.

Return E-FL-HB-0x00 to upright position. 

1

3

2

STAT

10BASE-FL

1

2

3

4

5

6

7

8

PWR

COL

ACT

BB

1

3

2

4

5

7

6

8

Содержание E-FL-HB-0400

Страница 1: ...imits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada European...

Страница 2: ...DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model E FL HB 0x00 Series Unmanaged Fiber Hub Part Number E FL HB 0800 E FL HB 0800 SC E FL HB 0400 E FL HB 0400 SC Regulation EMC Directive 89 336 EEC Purpose To declare that the E FL HB 0800 or E FL HB 0400 to which this declaration refers is in conformity with the following standards EMC CI...

Страница 3: ... Coaxial RG58 ThinNet Impedance 50 Ω 10 MHz Mutual Capacitance 24 pF ft 20 10 MHz Maximum Cable Length 185 meters 610 feet Maximum number network connections 30 Minimum distance between connections 0 5 meters 1 6 feet Terminate 10BASE 2 cable at one end using a 50 ohm terminator and at the other end using a 50 ohm terminator grounded to earth ground AUI 10BASE 5 Cable Specifications 10BASE 5 CABLE...

Страница 4: ...t against E FL HB 0x00 chassis 5 Secure backbone uplink adapter by installing retained screws through backbone uplink adapter into E FL HB 0x00 chassis 6 Is the B ack B one ACT ivity LED illuminated NO Disconnect and reconnect the backbone cable to restart the initialization process Restart the attached network device to restart the initialization process Contact Technical Support 800 260 1312 YES...

Страница 5: ...LINKAlert is NOT enabled the port is partitioned investigate the device at the far end of the link If the fiber backbone adapter plate is installed and LINKAlert IS enabled determine and correct the cause of the Far End Fault Contact Technical Support 800 260 1312 NO Continue at step 6 Install E FL HB 0x00 at Site WARNING During the site installation handle the E FL HB 0x00 in such a way that the ...

Страница 6: ...00 OPERATION Use the status LEDs to monitor E FL HB 0x00 operation in the network E FL 0X00 HUB INDICATORS P o W e R Steady LED indicates E FL HB 0x00 is connected to external AC power COL lision Flashing LED indicates network collisions B ACK B ONE INDICATORS STAT us Steady LED indicates for network connection a valid link and no partition or isolation One 1 continuous flashing blink indicates ne...

Страница 7: ...ion within acceptable bounds NOTE In a coax thinnet installation the first and last device in the daisy chain must be terminated using a 50 ohm terminator Additionally the 10BASE 2 segment must be grounded to earth ground at one end To connect to 10BASE 2 network 1 Locate BNC uplink adapter installed at E FL HB 0x00 back See page 4 2 Locate or build IEEE 802 3 compliant 10BASE 2 cable and male BNC...

Страница 8: ... Locate or build 10BASE FL compliant two stranded fiber cable with appropriate male TX to RX connectors installed at both ends 2 Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors respectively on front of one hub 3 Connect male TX and RX cable connectors at other end of cable to RX and TX connectors respectively on front of second hub Connect E FL 0x00 Hub t...

Отзывы: