INSTALLATION
Optionally Install Backbone Uplink Adapter
WARNING: Remove AC line cord from power source before installing
backbone uplink adaptor in E-FL-HB-0x00. Failure to observe this warning
could result in personal injury or death.
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing backbone uplink adaptor in the E-FL-HB-0x00.
Failure to observe this caution could result in damage to, and subsequent
failure of, backbone uplink adaptor.
To install the backbone uplink adapter in the E-FL-HB-0x00:
1.
Locate backbone uplink adapter plate at back of E-FL-HB-0x00.
2.
Remove backbone uplink adapter plate by using flatblade
screwdriver to remove two (2) screws that secure backbone uplink
adapter plate to back of E-FL-HB-0x00.
NOTE: Retain screws for step 5. (Optionally discard backbone
uplink adapter plate.)
3.
Carefully slide backbone uplink adapter, component side up, into
installation space revealed by removal of backbone uplink adapter
plate.
CAUTION: Do NOT force connection. Failure to observe this caution
could result in equipment damage and subsequent failure.
4.
Press component on backbone uplink adapter securely against
internal mating E-FL-HB-0x00 component until backbone uplink
adapter faceplate is flat against E-FL-HB-0x00 chassis.
5.
Secure backbone uplink adapter by installing retained screws
through backbone uplink adapter into E-FL-HB-0x00 chassis.
6.
Is the B(ack)B(one) ACT(ivity) LED illuminated?
NO
•
Disconnect and reconnect the backbone cable to restart the
initialization process.
•
Restart the attached network device to restart the initialization
process.
•
Contact Technical Support: (800) 260-1312.
YES
•
Continue at step 7.
7.
Is one (or more) of the 10BASE-FL STAT(us) LEDs illuminated
continuously?
YES
•
Continue at step 10.
NO
•
Continue at step 8.
8.
Does one (or more) of the 10BASE-FL STAT(us) LEDs
continuously blink ONCE?
YES
•
Check fiber cables for proper connection.
•
Verify that TX and RX cables on E-FL-HB-0x00 are connected to RX
and TX ports, respectively, on terminal device. (See page 9.)
•
Ensure that terminal device(s) is/are powered.
•
Contact Technical Support: (800) 260-1312.
NO
•
Continue at step 9.
9.
Does one (or more) of the 10BASE-FL STAT(us) LEDs
continuously blink TWICE?
YES
•
The port is (or ports are) partitioned; investigate the attached
terminal device(s).
•
Contact Technical Support: (800) 260-1312.
NO
•
Continue at step 10.
10.
Is one (or more) of the 10BASE-FL ACT(ivity) LEDs illuminated?
YES
•
The port is (or ports are) operational and receiving data.
NO
•
Disconnect and reconnect the 10BASE-FL cable to restart the
initialization process.
•
Restart the terminal device(s) to restart the initialization process.
•
Contact Technical Support: (800) 260-1312.
Backbone Uplink Adapter Plate