24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
CRS2F31xx-100
Technical Specifications
For use with Transition Networks Model CRS2F31xx-100 or equivalent
Data Rate
115 kB/s
(asynchronous)
Dimensions
3.4" x 5.0" x 0.86"
(86 mm x 127 mm x 22 mm)
Weight
3 oz. (91 g) approximately
Power Consumption
5 Watts
MTBF
2,613,860 hours
(MIL217F2 V5.0) (MIL-HDBD-217F)
6,569,957 hours (Bellcore7 V5.0)
Environment
Tmra*:
Storage Temp:
Humidity:
Altitude:
0 to 50°C
(32° to 122° F )
-
40
° to
+8
5°C
(
-40
° to
+
1
85
°F)
5 to 95%, non condensing
0 to 10,000 feet
Warranty
Lifetime
*Manufacturer’s rated ambient temperature. Tmra range for this slide-in-module
depends on the physical characteristics and the installation configuration of the
Transition Networks PointSystem™ chassis in which this slide-in-module will be
installed.
WARNING: Visible and invisible laser radiation when open. Do not stare into the
beam or view the beam directly with optical instruments. Failure to observe this
warning could result in an eye injury or blindness.
WARNING: Use of controls, adjustments or the performance of procedures other than
those specified herein may result in hazardous radiation exposure.
Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422,
RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra-building
(inside plant) link segments that are not subject to lightening transients or power faults.
Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422,
RS485, DS1, DS3, Video Coax, etc., are NOT to be connected to inter-building
(outside plant) link segments that are subject to lightening transients or power faults.
6
7
8
9
1
2
3
4
5
Da
t
a
S
e
t
Rea
d
y
Da
t
a Ca
rr
ie
r
De
t
ec
t
Reque
st
t
o
S
en
d
Clea
r
t
o
S
en
d
N
o
t
U
s
e
d
Receive Da
t
a
T
r
an
s
mi
t
Da
t
a
Da
t
a Te
r
minal Rea
d
y
S
i
g
nal G
r
oun
d
P
r
o
t
ec
t
ive G
r
oun
d
RS-232 Copper Cable
CRS2F3115-100
Gauge:
24 to 22 AWG
Maximum Data Rate
(asynchronous):
115 kB/s
Maximum Cable Distance:
15 m (50 ft.)
RS-232 Signals:
[email protected] -- Click the “Transition Now” link for a live Web chat.
9
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the answers
to the following questions and then taking the indicated action:
1.
Is the P
(power)
LED illuminated?
NO
•
Is the media converter inserted properly into the chassis?
•
Is the power cord properly installed in the chassis and in the grounded AC outlet?
•
Does the grounded AC outlet provide power?
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 2.
2.
Is the RX
(copper)
LED flashing?
NO
•
Disconnect and reconnect the RS-232 copper cable to restart the initialization
process.
•
Restart the attached device on the other end of the RS-232 cable to restart the
initialization process.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 3.
3.
Is the FL
(fiber)
LED illuminated?
NO
•
Check the fiber cables for proper connection.
•
Verify that the TX and RX cables on the media converter are connected to the RX
and TX ports, respectively, on the other media converter.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
•
Proceed to step 4.
4.
Is the FL
(fiber)
LED flashing?
YES
•
The media converter is in loop-back mode. To disable the loop-back function in
“Hardware” mode, set the loop-back switch to the "Norm" position. In “Software”
mode, at the SNMP interface, select “disable loop-back” option.
•
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
•
Proceed to step 5.