5.
Is Data Transfer Failing?
YES
•
Verify the local copper connection by starting a local copper loop-back
(hardware
mode: set the loop-back switch on the local media converter to “loop”, software
mode: enter the local copper loop-back command)
and then use a bit error test unit to
run a bit error test.
•
Verify the local fiber connection by starting a remote fiber loop-back
(hardware
mode: set the loop-back switch on the remote media converter to “loop”, software
mode: enter the remote fiber loop-back command)
and then use a bit error test unit to
run a bit error test.
•
Verify the remote copper connection by starting a remote copper loop-back
(hardware mode: set the loop-back switch on the remote media converter to “loop”,
software mode: enter the remote copper loop-back command)
and then use a bit error
test unit on the remote end to run a bit error test.
•
Verify remote fiber connection by starting a local copper loop-back
(hardware
mode: setting the loop-back switch on the local media converter to “loop”, software
mode: enter the local fiber loop-back command)
and then use a bit error test unit on
the remote end to run a bit error test.
NO
•
Contact Technical Support: US/Canada: 1-800-260-1312, International: 00-1-952-
941-7600.
Remote Converter
Local Converter
w/SNMP Management
r
e
p
p
o
c
r
e
b
i
F
r
e
p
p
o
c
Remote Converter
Local Converter
w/SNMP Management
r
e
p
p
o
c
r
e
b
i
F
r
e
p
p
o
c
Remote Converter
Local Converter
w/SNMP Management
r
e
p
p
o
c
r
e
b
i
F
r
e
p
p
o
c
Remote Converter
Local Converter
w/SNMP Management
r
e
p
p
o
c
r
e
b
i
F
r
e
p
p
o
c
Declaration of Conformity
Name of Mfg:
Transition Networks
10900 Red Circle Drive Minnetonka MN 55343 U.S.A.
Model:
CRS2F31xx-10x Series Media Converter
Part Number:
CRS2F3111-100, CRS2F3113-100, CRS2F3114-100,
CRS2F3115-100, CRS2F3129-100, CRS2F3129-101,
CRS2F3129-102, CRS2F3129-103
Regulation:
EMC Directive 89/336/EEC
Purpose: To declare that the CRS2F31xx-10x to which this declaration refers is in
conformity with the following standards.
CISPR 22: 1993; EN 55022:1998 Class A; FCC Part 15 Subpart B; EN 55024: 1998;
21 CFR subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
[email protected] -- Click the “Transition Now” link for a live Web chat.
11
Contact Us
Technical Support
Technical support is available 24 hours a day.
US and Canada:
1-800-260-1312
International:
00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support.
Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.
Ask a question anytime by sending an e-mail to our technical support staff.
[email protected]
Address
Transition Networks
10900 Red Circle Drive Minnetonka MN 55343, U.S.A.
telephone:
952-941-7600
toll free:
800-526-9267
fax:
952-941-2322
July 2008_____
Stephen Anderson, Vice-President of Engineering
Date