Cautions and Warnings 

Definitions 

  CAUTIONS indicate potential damage to equipment. 

 Warnings indicate potential hazard or injury to people. 

Cautions and warnings in this manual 

Cautions and Warnings are explained here and placed throughout this manual where appropriate. 

 CAUTION: While installing or servicing the power supply, wear a grounding device and observe all electrostatic 

discharge precautions. Failure to observe this caution could result in damage or failure of the power supply. 

 WARNING: Do not connect the power supply to an external power source before installing it into the chassis. 

Failure to observe this warning could result in an electrical shock, even death. 

 WARNING: A readily accessible, suitable National Electrical Code (NEC) or local electrical code approved 

disconnect device and branch-circuit protector must be part of the building's installed wiring. Failure to observe this 
warning could result in an electric shock, even death. 

 WARNING: Turn the power supply and external power source OFF and ensure that the power supply is 

disconnected from the external power source before performing any maintenance. Failure to observe this warning 
could result in an electrical shock, even death.

 

 

33458 Rev. B 

http://www.transition.com/ 

Page 2 of 14 

Содержание CPSMP-205

Страница 1: ... optional power supply into the chassis 6 Connecting power supply to external power 8 Maintenance 9 Replacing the CPSMP 205 power supply 9 Replacing the fuse 11 Technical Specifications 12 Troubleshooting 12 Contact Us 13 Compliance Information 13 Declaration of Conformity 13 Record of Revisions 14 Description Transition Networks CPSMP 205 AC power supply can deliver power or provide optional redu...

Страница 2: ...onnect the power supply to an external power source before installing it into the chassis Failure to observe this warning could result in an electrical shock even death WARNING A readily accessible suitable National Electrical Code NEC or local electrical code approved disconnect device and branch circuit protector must be part of the building s installed wiring Failure to observe this warning cou...

Страница 3: ... chassis Handle for installing and removing the power supply Fan exhausts warn air from the power supply AC power inlet receptacle for external AC power Figure 1 Power Supply Components Notices The CPSMP 205 AC power supply must be installed by qualified technical personnel only Transition Networks assumes no responsibility for the improper installation set up or use of this power supply The infor...

Страница 4: ...supply Either can be installed as the redundant power supply in an AC or DC powered Point System chassis CAUTION While installing or servicing the power supply wear a grounding device and observe all electrostatic discharge precautions Failure to observe this caution could result in damage or failure of the power supply Configuration switch The power supply contains a two position configuration sw...

Страница 5: ...ower supply the power supply is used for redundancy failover purposes in the event of a master power supply failure Configuring two power supplies in one chassis To set up power supply redundancy set one power supply to master that supplies power to the entire chassis and the other to slave for redundancy In this mode the slave power supply is in stand by mode and takes over in the event of a mast...

Страница 6: ...d the power supply s ON OFF switch is in the OFF position and it has been disconnected from its external power source To install the power supply in either the CPSMC1800 200 or the CPSMC1900 100 PointSystem chassis do the following Note The procedure is the same for installing the power supply into either slot 1 Push the power supply ON OFF switch to the OFF position See Figure 4 below Figure 4 Po...

Страница 7: ...low Figure 6 Two Position Configuration Switch 4 Position the power supply at the chassis slot See Figure 7 below Figure 7 Power Supply Installation 5 Side the power supply completely into the chassis 6 Insert the two screws shown in Figure 7 to mount the power supply to the chassis 33xxx Rev H http www transition com Page 7 of 14 ...

Страница 8: ...ower supply module to 0 2 Connect the female end of the AC power cord to the male end of the AC power connector 3 Connect the male end of the AC power cord into the correct voltage AC rack or wall socket 4 Set the ON OFF switch on the power supply module to I 5 Verify that the CPSMP 205 power supply module is powered ON by observing fan rotation and the illuminated power LED Figure 8 Connecting Po...

Страница 9: ...s been disconnected from its external power source and the ON OFF switch set to 0 To replace the CPSMP 205 power supply module 1 Ensure the ON OFF switch on the power supply module is set to 0 See Figure 9 below 2 Disconnect the AC power cord from the AC power source 3 Remove the two 2 screws that secure the power supply module to the chassis Retain the screws for installing the replacement module...

Страница 10: ...is 7 Carefully insert the two 2 retained screws through the power supply module into the chassis and tighten them 8 Plug the power cord into the power supply and into the external power source 9 Push the power ON OFF switch to the ON position Note that the fan is rotating and the power ON LED is lit 33458 Rev B http www transition com Page 10 of 14 ...

Страница 11: ...is set to 0 Off 2 Disconnect the AC power cord from the external power source 3 From the inside edge of the power receptacle insert a small flat blade screwdriver into the groove on the front inside edge of the fuse holder and carefully pry the fuse holder from the power supply module See Figure 11 below Figure 11 Replacing the Fuse 4 Carefully remove the fuse from the fuse holder 5 Install a same...

Страница 12: ...98 000 hours Bellcore7 V5 0 Operating Temperature 0 to 60 C 32 to 140 F Storage Temperature 20 to 85 C 4 to 185 F Humidity 5 to 95 non condensing Warranty Lifetime Troubleshooting If the power supply module fails isolate and correct the fault by determining the answers to the following questions and then taking the indicated action 1 Is the Power ON LED on the CPSMP 205 module lit NO Is the power ...

Страница 13: ...ion Now link Web based seminars Transition Networks provides seminars via live web based training Log onto www transition com and click the Learning Center link E Mail Ask a question anytime by sending an e mail to our technical support staff techsupport transition com Address Transition Networks 10900 Red Circle Drive Minnetonka MN 55343 U S A telephone 952 941 7600 toll free 800 526 9267 fax 952...

Страница 14: ...e at the user s own expense Canadian regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règl...

Отзывы: