Transition Networks
CPSMP-205 User Guide
Replacing the fuse
CAUTION: Ensure that the power supply module has been disconnected from the external power source
and the module’s ON/OFF switch has been set to “
0
”.
Failure to observe this caution could result in damage to, or failure of the power supply module.
Note
: The CPSMP-205 power supply module may be “hot swapped” (i.e., serviced while the chassis is in
operation) provided the module to be serviced has been disconnected from its external power supply and
the module’s ON/OFF switch has been set to “
0
”.
To replace the fuse in the CPSMP-205 power supply module:
1. Ensure the ON/OFF switch on the power supply module is set to “
0
” - Off.
2. Disconnect the AC power cord from the external power source.
3. From the inside edge of the power receptacle, insert a small flat blade screwdriver into the groove
on the front, inside edge of the fuse holder and carefully pry the fuse holder from the power
supply module. See Figure 11 below.
Figure 11: Replacing the Fuse
4. Carefully remove the fuse from the fuse holder.
5. Install a same size and rating (
250V, 4A
) replacement fuse in the fuse holder.
6. Insert the fuse holder containing the fuse into the fuse holder slot, and then push in to snap into
place.
7. Insert the female end of the power cord into the power supply receptacle and the other end into
the external AC power receptacle.
8. Push the power ON/OFF switch to the ON position. Note that the fan is rotating and the power
ON LED is lit.
33xxx Rev. H
http://www.transition.com/
Page 11 of 14