background image

13

.

Cable Specifications

-- Continued

T1/E1 Cable 

Category 3:  (minimum requirement)

Connector:

RJ-48C

Electrical network connection: 

Single 4-wire (Tip/Ring - Tip1/Ring1)

Mechanical arrangement: 

8-position miniature modular jack

Usage: 

1.544 Mb/s access lines

Interface codes:

04DU9 (any applicable)

Cable type:

Long Haul T1/E1:

0db, -7.5dp, -15db, -22db

E1:

E1 3.0V, 120 ohm

J1:

0-655’, 110 ohm

DSX-1:

0-133’, 133-266’, 266-399’,
399-533’, 533-655’, 100 ohm

4
5

Receive

Transmit

4
5

 (ring) R1

 (tip) T1

1

 (ring) R

1

R

2

(tip) T

2

T

R1
T1

from the

media converter

to the

network

3

3

6

6

7

7

8

8

dry contact A

dry contact B

(not used)

RS-232 Cable 

(included)

Connectors:

6-pin DIN and DB-9

Gauge:

24 to 22 AWG

Attenuation: 

20 dB/1000 ft. @ 10 MHz

Differential characteristic impedance: 100 ohm +/- 10% @ 10 MHz
Maximum cable distance:

<10 ft (3.2 m) @ 56 kb/s or higher

DB-9

DIN 6-pin

9

8

7

6

1

5

4

3

2

2

1

4

6

3

5

Clear to Send

Signal Ground

5

9

Receive Signal

Transmit Data

3

2

Transmit Signal

Request to Send

7

1

Signal Ground

Receive Data

2

3,5

12

S4TEF10xx-10x

.

Cable Specifications

The physical characteristics must meet or exceed ITU specifications. 

Fiber Cable 

Bit Error Rate:  

<10-9

Single mode fiber (recommended):

9 µm 

Multimode fiber (recommended):

62.5/125 µm 

Multimode fiber (optional):  

100/140, 85/140, 50/125 µm 

AS4TEF1011-100

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

AS4TEF1013-100

1300 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

AS4TEF1014-100

1310 nm single mode

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber-optic Receiver Sensitivity:

min: -31.0 dBm

max: -8.0 dBm

Link Budget:

16.0 dB

AS4TEF1015-100

(long haul)

1310 nm single mode

Fiber-optic Transmitter Power:

min: -8.0 dBm

max: -2.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Link Budget:

26.0 dB

AS4TEF1016-100

(extra long haul)

1310 nm single mode

AS4TEF1017-100

(long wave length) 1550 nm single mode

Fiber-optic Transmitter Power:

min: -5.0 dBm

max: 0.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -7.0 dBm

Link Budget:

29.0 dB

S4TEF1018-100

1300 nm multimode

Fiber-optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Link Budget:

11.0 dB

AS4TEF1029-100

13170 nm (TX)/1550 nm (RX) simplex

AS4TEF1029-101

1550 nm (TX)/1310 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -13.0 dBm

max: -6.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.0 dBm

max: -3.0 dBm

Link Budget:

19.0 dB

AS4TEF1029-102

1310 nm (TX)/1550 nm (RX) simplex

AS4TEF1029-103

1550 nm (TX)/1310 nm (RX) simplex

Fiber-optic Transmitter Power:

min: -8.0 dBm

max: -3.0 dBm

Fiber-optic Receiver Sensitivity:

min: -33.0 dBm

max: -3.0 dBm

Link Budget:

25.0 dB

The fiber optic transmitters on this device meets Class I Laser safety
requirements per IEC-825/CDRH standards and complies with 21
CFR1040.10 and 21CFR1040.11.

Содержание AS4TEF1011-100

Страница 1: ...F10xx 10x is designed to be installed in pairs For example install one S4TEF1011 100 as the local media converter and another S4TEF1011 100 as the remote media converter All S4TEF10xx 10x models have the following copper connectors The various fiber connectors are available on separate models Both duplex and single mode fiber optic converters are available Part Number Duplex Fiber Optic 100Base FX...

Страница 2: ...r must be installed in pairs Copper and Fiber Ports The figure below illustrates the locations of the fiber port the RS 232 data port and the four 4 T1 E1 ports Typical maximum cable distance Actual distance is dependent upon the physical characteristics of the network TX transmit RX receive 3 Installation Continued Configuration Switches The AS4TEF10xx 10x media converter has two 2 sets of config...

Страница 3: ... signal This function is un framed and applies to ALL channels both copper and fiber down Disables the transmit AIS function 10 RS 232 Port Mode up Data port mode normal operation Transmits data to a desk top computer or other data collection device down Local auxiliary management mode See the SNMP section page 11 for the commands that are supported via the RS 232 connector up down Enable Disable ...

Страница 4: ... see pages 3 6 Software The media converter mode is determined by the most recently saved on board microprocessor settings Hardware Mode Software Mode S H S H To set the jumper 1 Using a small screwdriver remove the four 4 screws that secure the cover and carefully remove the cover from the media converter 2 Locate the hardware software jumper 3 Using small needle nosed pliers or similar device mo...

Страница 5: ...ur T1 E1 ports are equipped with an RJ 48 dry contact relay The relay closes if the power is lost or if any of the individual T1 E1 E1 links are lost The operational rating on pins 3 and 6 are 0 30 VDC 100 mA maximum relay 3 6 RJ 48C connector T1 E1 port Connect the 6 pin DIN connector to the media converter as shown Connect the DB 9 connector to the computer RS 232 data cable enclosed 9 Installat...

Страница 6: ... and manage a networked S4TEF10xx 10x media converter at a remote location For more details see the C4TEF10xx 10x user s guide on line at www transition com SNMP See the on line documentation that comes with Transition Networks FocalPoint software for applicable commands and usage Use SNMP at an attached terminal or at a remote location to monitor the media converter by monitoring Media converter ...

Страница 7: ... 30 0 dBm max 14 0 dBm Link Budget 11 0 dB AS4TEF1013 100 1300 nm multimode Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB AS4TEF1014 100 1310 nm single mode Fiber optic Transmitter Power min 15 0 dBm max 8 0 dBm Fiber optic Receiver Sensitivity min 31 0 dBm max 8 0 dBm Link Budget 16 0 dB AS4TEF1015 100 long h...

Страница 8: ...may result in hazardous radiation exposure Optional Accessories The following items are available from Transition Networks Part Number Description SPS 1872 SA Optional External Power Supply 18 72VDC Stand Alone Output 12 6VDC 1 0 A WMBL Optional Wall Mount Bracket 4 0 in 102 mm WMBV Optional Vertical Mount Bracket 5 0 in 127 mm WMBD Optional DIN Rail Mount Bracket 5 0 in 127 mm 15 Troubleshooting ...

Страница 9: ... mode set the remote converter to T1 E1 loop back see page 4 SW mode enter the local T1 E1 loop back command at the remote converter Use a bit error test unit to run a bit error test Fiber T1 T1 Local Converter Remote Converter Bit Error Test Equipment Remote Device Fiber T1 T1 Local Converter Remote Converter Remote Device Bit Error Test Equipment Fiber T1 T1 Local Converter Remote Converter Bit ...

Отзывы: