Transition Networks AS4TEF1011-100 Скачать руководство пользователя страница 4

6

S4TEF10xx-10x

Installation 

-- Continued

Switch Set #2 - Serial Options

6 - not in use

7 - not in use

8 - not in use

9 - not in use

switches 6, 7, 8, & 9 are not in use

9

8

7

6

10 - Fiber Loop-Back 

up - Enables fiber loop-back.

down - disables fiber loop-back.  

The loop-back setting is used for installation
and network debugging procedures.  When
the fiber loop-back function is enabled, the
fiber port loops all T1/E1 signals from the
receive ports back to the transmit ports.  The
loop-back test scenarios are described in
detail on page 17.

up

down

Disables Loop-Back

Enables Loop-Back

10

7

.

Installation 

-- Continued

Hardware/Software Jumper

The hardware/software jumper is inside the media converter housing and is
located near the back end of the upper circuit board. 

Hardware The media converter mode is determined by

the switch settings (see pages 3 - 6).

Software

The media converter mode is determined by
the most-recently saved, on-board
microprocessor settings.

Hardware Mode

Software Mode

S

H

S

H

To set the jumper:

1.

Using a small screwdriver, remove the four (4)
screws that secure the cover and carefully
remove the cover from the media converter.

2.

Locate the hardware/software jumper.

3.

Using small needle-nosed pliers or similar
device, move the jumper to the desired position
(see above).

4.

Carefully replace the cover on the media
converter and replace the four (4) screws that
secure the cover to the media converter.

Power the Media Converter 

1.

Connect the barrel connector on the power adapter to the media
converter’s power port (located on the back of the media converter). 

2.

Connect the power adapter plug to AC power.

3.

Verify that the media converter is powered by observing the illuminated
LED power indicator light.

NOTE:  For DC power, consult the user’s guide for the Transition Networks
SPS1872-xx DC external power supply.

hardware/software

jumper

Содержание AS4TEF1011-100

Страница 1: ...F10xx 10x is designed to be installed in pairs For example install one S4TEF1011 100 as the local media converter and another S4TEF1011 100 as the remote media converter All S4TEF10xx 10x models have the following copper connectors The various fiber connectors are available on separate models Both duplex and single mode fiber optic converters are available Part Number Duplex Fiber Optic 100Base FX...

Страница 2: ...r must be installed in pairs Copper and Fiber Ports The figure below illustrates the locations of the fiber port the RS 232 data port and the four 4 T1 E1 ports Typical maximum cable distance Actual distance is dependent upon the physical characteristics of the network TX transmit RX receive 3 Installation Continued Configuration Switches The AS4TEF10xx 10x media converter has two 2 sets of config...

Страница 3: ... signal This function is un framed and applies to ALL channels both copper and fiber down Disables the transmit AIS function 10 RS 232 Port Mode up Data port mode normal operation Transmits data to a desk top computer or other data collection device down Local auxiliary management mode See the SNMP section page 11 for the commands that are supported via the RS 232 connector up down Enable Disable ...

Страница 4: ... see pages 3 6 Software The media converter mode is determined by the most recently saved on board microprocessor settings Hardware Mode Software Mode S H S H To set the jumper 1 Using a small screwdriver remove the four 4 screws that secure the cover and carefully remove the cover from the media converter 2 Locate the hardware software jumper 3 Using small needle nosed pliers or similar device mo...

Страница 5: ...ur T1 E1 ports are equipped with an RJ 48 dry contact relay The relay closes if the power is lost or if any of the individual T1 E1 E1 links are lost The operational rating on pins 3 and 6 are 0 30 VDC 100 mA maximum relay 3 6 RJ 48C connector T1 E1 port Connect the 6 pin DIN connector to the media converter as shown Connect the DB 9 connector to the computer RS 232 data cable enclosed 9 Installat...

Страница 6: ... and manage a networked S4TEF10xx 10x media converter at a remote location For more details see the C4TEF10xx 10x user s guide on line at www transition com SNMP See the on line documentation that comes with Transition Networks FocalPoint software for applicable commands and usage Use SNMP at an attached terminal or at a remote location to monitor the media converter by monitoring Media converter ...

Страница 7: ... 30 0 dBm max 14 0 dBm Link Budget 11 0 dB AS4TEF1013 100 1300 nm multimode Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB AS4TEF1014 100 1310 nm single mode Fiber optic Transmitter Power min 15 0 dBm max 8 0 dBm Fiber optic Receiver Sensitivity min 31 0 dBm max 8 0 dBm Link Budget 16 0 dB AS4TEF1015 100 long h...

Страница 8: ...may result in hazardous radiation exposure Optional Accessories The following items are available from Transition Networks Part Number Description SPS 1872 SA Optional External Power Supply 18 72VDC Stand Alone Output 12 6VDC 1 0 A WMBL Optional Wall Mount Bracket 4 0 in 102 mm WMBV Optional Vertical Mount Bracket 5 0 in 127 mm WMBD Optional DIN Rail Mount Bracket 5 0 in 127 mm 15 Troubleshooting ...

Страница 9: ... mode set the remote converter to T1 E1 loop back see page 4 SW mode enter the local T1 E1 loop back command at the remote converter Use a bit error test unit to run a bit error test Fiber T1 T1 Local Converter Remote Converter Bit Error Test Equipment Remote Device Fiber T1 T1 Local Converter Remote Converter Remote Device Bit Error Test Equipment Fiber T1 T1 Local Converter Remote Converter Bit ...

Отзывы: