B.1.3 SIMPLEX MODE
The Simplex Mode provides a continuous serial transmission mode and is selected
by setting A3 to
“
C
”
and A16 to
“
PC
”
. The Continuous mode is used to interface to
computers, scoreboards, and other remote devices requiring constant data
updating. The transmission occurs at the end of each display update. Figure B-5
shows the serial data format for Continuous Mode.
<STX>
<POL>
xxxxx.xx
<L/K> <G/N>
<STAT>
<CR>
<LF>
Polarity:
<SP> = Positive
"
–
"
= Negative
Weight Data
Units:
L = pound
K = kilogram
Gross/Net:
G = Gross
N = Net
Start
Transmission
Carriage
Return
Line
Feed
Status:
<SP> = Valid
M = Motion
O = Over/under range
P = pieces
C = custom units
* Available on TI-500E and TI-500E-SS only
PCS = pieces*
FIGURE B-5. Consolidated Controls Continuous Mode