Programming Codes
Ithaca
®
8000
Programmer’s Guide
100-06908
Rev D
Page 125
Function
Load item from user store
ASCII
[ESC] [US] l <Name..> <0>
Hexadecimal
1BH 1FH 6CH
Decimal
<27> <31> <108>
IPCL
&%UL <Name..> <0>
EPOS
[GS] 0<Name..> <0> is from one to 15 characters and must be null
terminated.
Description
The [ESC] [US] l <Name..> <0> command loads the referenced item into
the appropriate structure. If the item referenced is a user-defined
character set, it is loaded into the current user-character definition, which
does not affect the active state of user-defined characters. If it is a
macro, it is loaded into the macro buffer, but it is not inserted into the data
stream. [ESC] g <0> inserts the macro buffer into the data stream. If the
named item does not exist, the command does nothing.
The terminating <0> may be replaced with an & or redefined. See [ESC]
[EM]T<n> or &%UT>n> on page 127.
Function
Run macro data from user store
ASCII
[ESC] [US] r <Name..> <0>
Hexadecimal
1BH 1FH 72H
Decimal
<27> <31> <114>
IPCL
&%UR <Name..> <0>
EPOS
[GS] 0
<
Name..> <0> is from one to 15 characters and must be null
terminated.
Description
The [ESC] [US] r <Name..> <0> command loads the referenced macro
into the macro buffer. The macro buffer is then inserted into the data
stream. If the named item does not exist or is not a macro, nothing
happens.
The terminating <0> may be replaced with an & or redefined. See [ESC]
[EM]T<n> or &%UT<n> on page 127.
Function
Flag item as a start-up macro
ASCII
[ESC] [US] s <Name..> <0>
Hexadecimal
1BH 1FH 73H
Decimal
<27> <31> <115>
IPCL
&%US <Name..> <0>
EPOS
[GS] 0
<
Name..> <0> is from one to 15 characters and must be null
terminated.
Description
The [ESC] [US] s <Name..> <0> command flags the referenced item to
be processed at startup. Only one user character definition and one
macro may be flagged to run at startup.
Note:
If a character definition is loaded at startup, it is automatically made
active.
The terminating <0> may be replaced with an & or redefined. See [ESC]
[EM]T<n> or &%UT<n> on page127
Содержание Ithaca 8000
Страница 1: ...Ithaca 8000 Programmer s Guide PN 100 06908 Rev D November 2010...
Страница 2: ...This page intentionally left blank...
Страница 13: ...100 06908 Rev D Page xi...
Страница 14: ......
Страница 15: ...100 06908 Rev D Page 1 chapter 1 Introducing your Ithaca 8000 Printer...
Страница 16: ...Page 2 Rev D 100 06908 This page intentionally left blank...
Страница 22: ......
Страница 23: ...100 06908 Rev D Page 9 chapter 2 Ithaca 8000 Specifications and Requirements...
Страница 24: ...Page 10 Rev D 100 06908 This page intentionally left blank...
Страница 42: ...Page 28 Rev D 100 06908 chapter 3 Setup Procedures...
Страница 43: ...100 06908 Rev D Page 29 This page intentionally left blank...
Страница 51: ...100 06908 Rev D Page 37 chapter 4 How to Operate the Ithaca 8000 Printer...
Страница 52: ...Page 38 Rev D 100 06908 This page intentionally left blank...
Страница 60: ......
Страница 61: ...100 06908 Rev D Page 47 chapter 5 Configuring Your Ithaca 8000 Printer...
Страница 62: ...Page 48 Rev D 100 06908 This page intentionally left blank...
Страница 68: ......
Страница 69: ...100 06908 Rev D Page 55 chapter 6 Programming Codes...
Страница 70: ...Page 56 Rev D 100 06908 This page intentionally left blank...
Страница 251: ...100 06908 Rev D Page 237 chapter 7 Ithaca 8000 Color Graphics...
Страница 252: ...Page 238 Rev D 100 06908 This page intentionally left blank...
Страница 267: ...100 06908 Rev D Page 253 chapter 8 Unicode...
Страница 268: ...Page 254 Rev D 100 06908 This page intentionally left blank...
Страница 272: ......
Страница 273: ...100 06908 Rev D Page 259 chapter 9 Ithaca 8000 Extended Printer Control...
Страница 274: ...Page 260 Rev D 100 06908 This page intentionally left blank...
Страница 280: ......
Страница 281: ...100 06908 Rev D Page 267 chapter 10 Communications...
Страница 282: ...Page 268 Rev D 100 06908 This page intentionally left blank...
Страница 306: ......
Страница 310: ......
Страница 312: ......