18
CAUTION: Always refer to the altimeter manufacturer’s data for maximum rate of climb
or descent and any special test conditions which must be complied with.
Adjust the input pressure until the altimeter is exactly reading a 1000 footmark. Note the
difference between the digitizer and the altimeter. For example:
Adjust the input pressure until the altimeter is reading
10,000 feet.
In this case the altimeter reads 20,000 feet and the
encoder/digitizer
reads 20,080.
Type “
ADJ<enter>
” the computer should now display
“
A=
”
Type “
S20 <enter>
”
(
S20
represents
Save 20,000feet
)
4.5 SSD120-(XX)M Calibration Adjustment Procedure (continued)
The digitizer will now output 20,000 based on the altimeter reading. And the PC will
display the altitude at which the digitizer will make this change. In the example above
the PC would display
>20000.
Proceed to the next 1000 foot mark and repeat the procedure as in step 3above until the
entire operating range of the altimeter encoder/digitizer is complete.
(Note: If no correction is required at an altitude simply do not enter a
correction.)