Trango
Systems,
Inc
TL45
User
Manual
Rev
2.0r3
LT
‐
9037A
August
15,
2011
Page
58
Environmental
Operating
Temp:
‐
40
to
60
deg
C
Storage:
‐
40
to
85
deg
C
Humidity:
100
%
when
sealed
properly
NEMA
Rating:
NEMA
4
Shock:
Sustain
3
axis
drop
from
5
feet
Power
Parameters
Input
Voltage:
Input
voltage
range
at
unit
is
15
VDC
to
24
VDC
max.
Power
is
supplied
on
Ethernet
cable
using
junction
box
provided
with
up
to
330
foot
24
AWG
STP
cable.
Current
Cons.:
Max
600
mA
in
transmit
and
receive
modes
using
24
V
standard
adapter
(12
W)
with
short
Ethernet
cable
from
Junction
box
to
radio.
Power
Supply
Type:
Switch
mode
wall
mount
transformer
Safety:
PSE,
UL,
CUL,
GS
EMI:
FCC
Class
B,
VCC
‐
II,
CE
Input:
90
–
255
VAC
Plug
Type:
Includes
4
plug
blades
for
to
allow
use
in
US,
Europe,
UK
and
Australia
Output:
24
VDC
+/
‐
1
V
Max
current:
1000
mA
Antennas
Integrated
19
dBi
Antenna
(for
P5055M
‐
19
‐
xx)
Frequency
range:
4950
‐
5850
MHz
Gain:
19
dBi
+/
‐
1
dB
Front/Back
Ratio
>30
dB
E
‐
Plane
Beamwidth:
>
18
degrees
typical
H
‐
Plane
Beamwidth:
>
18
degrees
typical
Polarization:
Vertical
and
Horizontal
Port/Port
Isolation:
20
dB
typ
Cross
Pol
Rejection:
20
dB
typ
VSWR:
<1.7:1
Package:
Alumininum
backplate
with
plastic
radome.
Dimensions:
8.5"
x
7.75"
x
1.25"
(216mm
x
197mm
x
32mm)
Weight:
2
lbs
(.91Kg)
Mounting
Provisions:
Mounting
kit
supplied
for
up
to
3”diam
pole
or
flat
surface
Azimuth/El
Adjust:
+/
‐
30
degrees
Sealing:
Water
tight
to
1
meter
IEC
529/IP67
Temp
Range:
‐
40
deg
F
to
+160
deg
F
(
‐
40
deg
C
to
+60
deg
C)
Wind
speed
operational:
100
mph
(160
km/hr)
Wind
speed
survival:
140
mph
(220
km/hr)