Trango
Systems,
Inc
TL45
User
Manual
Rev
2.0r3
LT
‐
9037A
August
15,
2011
Page
24
Master
Unit
Configuration
Start
a
telnet
session
with
one
of
the
radios.
Follow
these
steps
for
configuration.
1.
Set
the
Unit
Type
(utype)
to
MU
in
one
radio.
(default
for
all
radios
is
RU)
#> utype mu
Success.
#>
2.
Set
the
Peer
ID
with
the
MAC
address
of
the
RU.
Only
use
the
last
8
digits
of
the
MAC
address.
#> peerid
de1B7850
Success.
#>
3.
Set
channel
and
polarization.
(in
this
example
set
the
channel
to
2
and
polarization
to
H).
#> freq 2 h
Ch# 23 h (5280 MHz)
Success.
4.
Set
default
Opmode
to
ON
.
#> defaultopmode on
Success.
5.
Reboot
the
radio
#> reboot
(NOTE:
It
is
critical
to
reboot
after
the
utype
has
been
changed
before
turning
Opmode
“On”)
After
the
radio
reboots,
start
another
telnet
session
with
the
radio
and
proceed
as
follows:.
1.
Turn
Opmode
ON.
#> opmode on
Success.
.
Remote Unit Configuration
Configure
the
RU
in
the
same
manner
as
the
MU.
Since
the
default
unit
type
(utype)
is
RU,
you
do
not
need
to
set
this
parameter.
1.
Set
the
Peer
ID
with
the
MAC
address
of
the
MU.
Only
use
the
last
8
digits
of
the
MAC
address
.
#> peerid de
1B7842
Success.
#>
2.
Set
channel
and
polarization.
(in
this
example
set
the
channel
to
2
and
polarization
to
H).
#> freq 2 h
Ch# 2 h (5280 MHz)
Success.
3.
Set
default
Opmode
to
“ON.”
#> defaultopmode on
Success.
4.
Reboot
the
radio
#> reboot