32-5035-16  

7

User’s Information

For vertical UPFLOW ONLY, a left or right return air 
inlet as above (left side shown) requires trimming of 
the factory supplied filter to 17" x 25" x 1" for both the 
21" and 24-1/2" wide furnaces.
Air filters may also be located outside of the furnace 
using a 

SIDE FILTER FRAME.

Upflow/ Horizontal Furnace Filters

The Upflow/ Horizontal furnace when installed hori-
zontally requires a horizontal filter kit. The filters may 
be located remote to the furnace or in the return air 
duct near the furnace. Check with your dealer for the 
location of your filters.
An upflow/horizontal furnace in horizontal return air 
filter application, as shown, features two 16" x 20" x 
1" filters in the 17-1/2", 21" and 24-1/2" wide furnace 
cabinets.
To replace filters, remove the filter access door, lift the 
filter from the lower bracket and shift the filter to the 
side to free the top filter from the bracket and slide the 
filters out through the filter access door. After cleaning, 
replace the filters in the same manner making sure 
that the filters are secured in place in both top and bot-
tom filter brackets. Replace filter access door.

REQUIRED FILTERS - BOTTOM

CABINET WIDTH

FILTER QUANTITY & SIZE

17-1/2"

1 - 17" X 25" X  1"

21"

1 - 20" X 25" X  1"

24-1/2"

1 - 24" X 25" X  1"

REQUIRED FILTERS - SIDE  **

CABINET WIDTH

FILTER QUANTITY & SIZE

17-1/2"

1 - 17" X 25" X  1"

21"

1 - 17" X 25" X  1"

24-1/2"

1 - 17" X 25" X  1"

** ON UPFLOW 5 TON AIRFLOW MODELS, IF THE AIR-

FLOW REQUIREMENT EXCEEDS 1800 CFM, THESE 

MODELS WILL REQUIRE FILTERS ON BOTH SIDES 

OR

 

1 SIDE AND THE BOTTOM, 

OR

 JUST THE BOTTOM

UPFLOW  

ONLY

Airflo

w

DOWNFLOW FILTER

Airflow

UPFLOW/HORIZONTAL WITH FILTER KIT

Airflow

Air filters may also be located outside of the furnace 
using a remote filter grille

The filter grille could be in 

a hallway, wall, or in the ceiling. Check with your deal-
er for the exact location of your filter and the method 
of changing the filters.

UPFLOW (Vertical) FILTER TABLES

Downflow/ Horizontal furnaces are factory supplied 
with 2 standard size permanent type air filters which 
may be located remote to the furnace or in the return 
air duct.  Check with your dealer for the location of 
your filters.
A downflow/ horizontal furnace return air filter appli-
cation, as shown, features two 14" x 20" x 1" filters in 
the 17-1/2" wide furnace cabinets; or two 16" x 20" x 1" 
filters in the 21" and 24-1/2" wide furnace cabinets.

Содержание XV95

Страница 1: ...switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depar...

Страница 2: ...iate NIOSH approved respirator in these situations FIRST AID MEASURES Eye Contact Flush eyes with water to remove dust If symptoms persist seek medical attention Skin Contact Wash affected areas gentl...

Страница 3: ...Also air openings provided to the area in which the fur nace is installed and the space around the furnace shall not be blocked or obstructed Keep this in mind should you choose to remodel the area w...

Страница 4: ...Start the Furnace Your furnace will have a switch to turn the gas ON or OFF 5 Turn the external main gas shutoff valve and the toggle switch located on the main gas valve inside the unit to the ON pos...

Страница 5: ...ny questions UPFLOW FURNACE Manual Main Gas Shut off Valve May Be Located on the Left or Right Side DOWNFLOW FURNACE Manual Main Gas Shutoff Valve May Be Located on the Right or Left Side AUTOMATIC GA...

Страница 6: ...er a BOTTOM or SIDE left or right return air inlet The filter may be secured with filter retaining brackets as shown or a filter rack To clean or replace filters remove blower access door slide the fi...

Страница 7: ...n both top and bot tom filter brackets Replace filter access door REQUIRED FILTERS BOTTOM CABINET WIDTH FILTER QUANTITY SIZE 17 1 2 1 17 X 25 X 1 21 1 20 X 25 X 1 24 1 2 1 24 X 25 X 1 REQUIRED FILTERS...

Страница 8: ...r syn thetic solvents may damage the finish DOWNFLOW Vertical FILTER TABLE REQUIRED FILTERS DOWNFLOW CABINET WIDTH FILTER QUANTITY SIZE 17 1 2 2 14 X 20 X 1 21 2 16 X 20 X 1 24 1 2 2 16 X 20 X 1 DOWNF...

Страница 9: ...so as to provide a seal between the support and the base e There are no obvious signs of deterioration of the furnace f The burner flames are in good adjustment without erratic flames See illustation...

Страница 10: ...corrosion and or de terioration at the beginning of each heating season by a qualified service technician and cleaned annu ally for best operation 6 CIRCUIT PROTECTION If blower or gas valve fail to...

Страница 11: ...ider in accordance with the Product specifications or installation opera tion and maintenance instructions provided by Company with each Product Failure to conform to such specifications and or instru...

Страница 12: ...ed Warranty Periods for certain Products will be extended as stated below Registered Limited Warranty Period SINGLE PHASE R410 OUTDOOR UNITS Base Limited Warranty Period Compressor Outdoor Coil Parts...

Страница 13: ..._________________________________________________________ Indoor Coil Serial Number______________________________________________________________________________ Indoor Coil Model Number______________...

Страница 14: ...14 32 5035 16 User s Information NOTES...

Страница 15: ...32 5035 16 15 User s Information NOTES...

Страница 16: ...duct and product data improvement it reserves the right to change design and specifications without notice Trane 6200 Troup Highway Tyler TX 75707 For more information contact your local dealer distri...

Отзывы: