background image

 32-5035-16

User’s Information

Proper Maintenance

A clean filter saves money.

When the furnace circulates and filters the air in your 
home, dust and dirt particles build up on the filter. Ex-
cessive accumulation can block the airflow, forcing the 
unit to work harder to maintain desired temperatures.
And the harder your unit has to work, the more energy 
it uses. So you pay more any time your system is run-
ning with a dirty filter. 

CAUTION

!

Never operate your unit for either heating or cooling 

with filters removed.

 
Help ensure top efficiency by cleaning the filter once 
a month. Clean it twice a month during seasons when 
the unit runs more often.
You can clean the filter with a vacuum, OR you can 
wash it with a household detergent.  
 

NOTE:  Not all aftermarket filters can be washed with 
a household detergent.  See the instructions supplied 
by the aftermarket filter manufacturer.

How to remove your filter.

WARNING

!

ELECTRIC SHOCK HAZARD

DISCONNECT POWER TO UNIT BEFORE REMOVING 

BLOWER DOOR.  

FAILURE TO FOLLOW THIS WARNING 

COULD RESULT IN PROPERTY DAMAGE, PERSONAL 

INJURY OR DEATH.

 
Upflow furnaces use a high velocity type air filter 
which may be located within the furnace blower com-
partment in either a BOTTOM or SIDE (left or right) 
return air inlet. The filter may be secured with filter 
retaining brackets (as shown) or a filter rack.
To clean or replace filters, remove blower access door, 
slide the filter from the filter rack or remove the filter  
from the retaining brackets. After cleaning, replace the 
filter in the same manner, making sure that the filter 
is secured in place in both the front and back filter re-
taining brackets, if present, or that the filter is secure-
ly slid all the way into the filter rack. Replace blower 
access door.  A bottom return air inlet as shown fea-
tures a 17" x 25" x 1" filter in the 17-1/2" wide furnace; 
cabinets; a 20" x 25" x 1" filter in the 21" wide models; 
and a 24" x 25" x 1" filter in the 24-1/2" wide cabinet.

When replacing your furnace filters, always use a high 
velocity type which are the same size as originally sup-
plied. Filters are available from your dealer.
Where disposable filters are used, they must be a high 
velocity type which are the same size as originally sup-
plied.

AIR FILTERS
Clean the filter once a month for optimum perfor-
mance.  A monthly visual inspection of the furnace 
is also recommended.  See General Inspection 
on page 9, number 1.

NOTE:  Filters are NOT included with all Furnaces, how-

ever; the Furnace should never be run without a filter.

Your filter may or may not be framed.

Airflow

UPFLOW 

SIDE RETURN

Airflow

UPFLOW

BOTTOM RETURN

Airflow

Содержание XV95

Страница 1: ...switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depar...

Страница 2: ...iate NIOSH approved respirator in these situations FIRST AID MEASURES Eye Contact Flush eyes with water to remove dust If symptoms persist seek medical attention Skin Contact Wash affected areas gentl...

Страница 3: ...Also air openings provided to the area in which the fur nace is installed and the space around the furnace shall not be blocked or obstructed Keep this in mind should you choose to remodel the area w...

Страница 4: ...Start the Furnace Your furnace will have a switch to turn the gas ON or OFF 5 Turn the external main gas shutoff valve and the toggle switch located on the main gas valve inside the unit to the ON pos...

Страница 5: ...ny questions UPFLOW FURNACE Manual Main Gas Shut off Valve May Be Located on the Left or Right Side DOWNFLOW FURNACE Manual Main Gas Shutoff Valve May Be Located on the Right or Left Side AUTOMATIC GA...

Страница 6: ...er a BOTTOM or SIDE left or right return air inlet The filter may be secured with filter retaining brackets as shown or a filter rack To clean or replace filters remove blower access door slide the fi...

Страница 7: ...n both top and bot tom filter brackets Replace filter access door REQUIRED FILTERS BOTTOM CABINET WIDTH FILTER QUANTITY SIZE 17 1 2 1 17 X 25 X 1 21 1 20 X 25 X 1 24 1 2 1 24 X 25 X 1 REQUIRED FILTERS...

Страница 8: ...r syn thetic solvents may damage the finish DOWNFLOW Vertical FILTER TABLE REQUIRED FILTERS DOWNFLOW CABINET WIDTH FILTER QUANTITY SIZE 17 1 2 2 14 X 20 X 1 21 2 16 X 20 X 1 24 1 2 2 16 X 20 X 1 DOWNF...

Страница 9: ...so as to provide a seal between the support and the base e There are no obvious signs of deterioration of the furnace f The burner flames are in good adjustment without erratic flames See illustation...

Страница 10: ...corrosion and or de terioration at the beginning of each heating season by a qualified service technician and cleaned annu ally for best operation 6 CIRCUIT PROTECTION If blower or gas valve fail to...

Страница 11: ...ider in accordance with the Product specifications or installation opera tion and maintenance instructions provided by Company with each Product Failure to conform to such specifications and or instru...

Страница 12: ...ed Warranty Periods for certain Products will be extended as stated below Registered Limited Warranty Period SINGLE PHASE R410 OUTDOOR UNITS Base Limited Warranty Period Compressor Outdoor Coil Parts...

Страница 13: ..._________________________________________________________ Indoor Coil Serial Number______________________________________________________________________________ Indoor Coil Model Number______________...

Страница 14: ...14 32 5035 16 User s Information NOTES...

Страница 15: ...32 5035 16 15 User s Information NOTES...

Страница 16: ...duct and product data improvement it reserves the right to change design and specifications without notice Trane 6200 Troup Highway Tyler TX 75707 For more information contact your local dealer distri...

Отзывы: