NOTE:

If the current time is Daylight Savings Time, press
Daylight Time until DST displays.

4.

Press Run Program.

INSTALLER SELF-TEST

Use the Installer Self-Test to check the thermostat operation.
Refer to Table 4 for a list of the available self-tests.

CAUTION

Equipment Damage Hazard.
Equipment damage can occur if the compressor
is cycled too quickly.
The minimum off time is deactivated during the
Installer Self-Test.
Perform the test so that the compressor is cycled
slowly.

To start the self-test:

Press and hold the Increase 

 and Decrease

 ▼

 keys at the

same time until all display segments and the number 10
appears (all displays segments appear for approximately
three seconds before the test number displays). See
Figs. 14 and 15.

Table  3. Installer Setup Options for the XT500C 

(Continued).

IMPORTANT

Review the settings to confirm that they match the system. Press Run Program to exit the Installer Setup. The
thermostat saves the Installer Setup changes and initiates a reset in order to operate using the new settings.

NOTE:

For initial installations only, set the current day and time following the setup reset.

NOTE:

Sun=Sunday, Mon=Monday, Tue=Tuesday,
Wed=Wednesday, Thu=Thursday, Fri=Friday,
Sat=Saturday.

3. Press Time 

 or Time 

 until the current time displays.

Setting Current Day and Time

1. Press Set Current Day/Time.

NOTE:

On initial power up or after an extended power loss,
1:00 pm flashes on the display until a key is pressed.

2. Press Day until the current day displays.

NOTE:

Tapping the Set Current Day/Time will change the
time in one hour increments.

Press Time  

▲ 

or

 ▼  

 

Press Increase 

 or Decrease 

 to change setting

Installer   

Factory Setting

Other Choices

Actual

Select

Setup Number

Display

Description

Display

Description

Setting

Minimum Off Time
(Cool)

39

5

5 minute minimum off
time for the compressor

0 thru 15

Minimum number of
minutes (0 thru 15) the
compressor will be off
between calls for cool

Cooling Droop

41

1

Cooling droop activated

0

No cooling droop

Programming

42
Press Time 

▼   

to bypass 2–41
and go directly   
to setup #42

0

7-day programming

1 or 2

1—24-hour
programming
2—No programming

Set Current

Day/Time

Time

Set Program

System

Filter

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

M14629

Set Day/Time

Mon

PM

Time

Set Program

System

Filter

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

Day

M14630

Set Day/Time

PM

Tue

Time

Set Program

System

Filter

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

Time

M14631

Set Day/Time

AM

Tue

Time

Set Program

System

Filter

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

Daylight

Time

M14632

Set Day/Time

AM

DST

Tue

Run

Program

Time

Set Program

System

Filter

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

M14633

Wake

Room

System

Fan

Heat

Auto

AM

DST

Tue

Содержание XT500C

Страница 1: ...nd on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After completing installation use these instructions to check...

Страница 2: ...e is located near each terminal for identification WARNING Electrical Shock or Equipment Damage Hazard Can shock individuals or cause equipment damage Disconnect power before wiring to prevent electri...

Страница 3: ...heating and cooling operation depending on the indoor temperature Time Set Program System Filter Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight...

Страница 4: ...s on changing the default settings Table 2 Default Program Settings M17150 LED INDICATOR M14610 Aux Ht System Em Heat Em Ht FLAME DISPLAYS DURING CALL FOR HEAT AUX HT DISPLAYS WHEN SYSTEM CALLS FOR AD...

Страница 5: ...of all the segments of the LCD IMPORTANT Only configurable numbers display Example Installer Setup Number 1 does not display because it is not configurable Review the factory settings in Table 3 and...

Страница 6: ...system starts early so setpoint is reached by start of program period 1 Conventional recovery system starts recovery at programmed time Degree temp erature display 14 0 Temperature displays in F 1 Tem...

Страница 7: ...essor 0 thru 15 Minimum number of minutes 0 thru 15 the compressor will be on during call for cool Temperature range stops in heating 34 85 Highest setpoint heating can be set to 55 to 85 Temperature...

Страница 8: ...shes on the display until a key is pressed 2 Press Day until the current day displays NOTE Tapping the Set Current Day Time will change the time in one hour increments Press Time or Press Increase or...

Страница 9: ...eat On Auto Off Cool Auto AM PM Hold for Heat Cool Repl Batt Recovery DST Tue Wed Thu Fri Sat Sun Days Temporary Setting Em Ht M14612 Key to Press Test Number Description Heating Equipment Self Test 1...

Страница 10: ...and Comfort R is enabled display reads If the terminals are closed no displays Keyboard Operation Self Test 60 Time 60 7 Enter keyboard operation self test Temp 60 9 Increase test number displays Tem...

Страница 11: ...ceed with troubleshooting Temperature display is incorrect Room temperature display has been reconfigured Enter Installer Setup number 37 and reconfigure the display Thermostat is configured for F or...

Страница 12: ...g setpoint Set cooling setpoint to desired temperature Heating or cooling comes on momentarily and shuts off Heat or cool circuit is opening up or becoming high impedance Add resistor in parallel with...

Отзывы: