background image

 

22-1825-09

Model 

Nomenclature

Refrigerant Type

2 = R-22

4 = R-410A

TRANE
Product Type

W = Split Heat Pump

T = Split Cooling

Product Family

Z = Leadership – Two Stage

X = Leadership

R = Replacement/Retail

B = Basic

A = Light Commercial

Family SEER

0 = 10 

3 = 13 

6 = 16

1 = 11 

4 = 14 

8 = 18

2 = 12 

5 = 15 

9 = 19

Split System Connections 1-6 Tons

0 = Brazed

Nominal Capacity in 000s of BTUs
Major Design Modifications
Power Supply

1 = 200-230/1/60 or 208-230/1/60

3 = 200-230/3/60

4 = 460/3/60

Secondary Function
Minor Design Modifications
Unit Parts Identifier

Outdoor Units

4 T T Z 0 0 3 6 A 1 0 0 0 A A

T   U   D   1   B   0   8   0   A   9   H   3   1   A   A

Furnace Configuration

TU = Upflow/Horizontal

TD = Downflow/Horizontal

Type

E = 80% Induced Draft Standard

D = 80% Induced Draft Premium

C = 90% Condensing Standard

X = 90% Condensing Premium

H = 95% Condensing Premium

Number of Heating Stages

1 = Single Stage

2 = Two Stage

M = Modulating

Major Design Change

Minor Design Change

Service Digit - Not Orderable

Heating Input in 1000’s (BTUH)

080 = 80,000 BTUH

Cabinet Width

A = 14.5" Cabinet Width

B = 17.5" Cabinet Width

C = 21.0" Cabinet Width

D = 24.5" Cabinet Width

Air Capacity for Cooling

Standard PSC  Variable Speed  High Efficiency

24 = 2 Tons 

V3 = 3 Tons 

H3 = 3 Tons

36 = 3 Tons 

V4 = 4 Tons 

H4 = 4 Tons

42 = 3.5 Tons 

V5 = 5 Tons 

H5 = 5 Tons

45 = 4 Tons

48 = 4 Tons

54 = 5 Tons

60 = 5 Tons

72 = 6 Tons

Voltage

9 = 115 Volts / 60 Hertz / Natural Gas

A = 115 Volts / 50 Hertz / Natural Gas

C = 115 Volts / Natural Gas with Communicating System Control

F = 115 Volts / Natural Gas with Integrated Electronic Filter

D = 115 Volts / Natural Gas with Communicating System Control and

  Integrated Electronic Filter

Draft Inducer Speeds

1  = Single Speed

2  = Two Speed

V = Variable Speed

Gas Furnaces

G   A   M   5   A   0   B   3   6   M   3   1   S   A   A

Brand

T  = Better

G = Good 

Product Type

A = Air Handler

Product Tier

2 = Good, Entry Level Feature Set

4 = Better, Retail Replacement Mid Effy.

5 = Better, Entry Level High Effy., Multi-Speed

7 = Best, Retail Replacement High Effy.,

  

Variable-Speed

8 = Best, Retail Ultimate High Effy., 

  

Variable-Speed

Major Design Change

Minor Design Change
Unit Parts Identifier

Airflow Type & Capability

S = Low Effy PSC, 1-5 - nom. Tonnage (cfm/ton)

M = Mid Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton)

H = High Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton)

V = High Effy Variable, 1-5 - nom. Tonnage (cfm/ton)

No Descriptor

0 = Air Handler / Coil

System Control Type

S = Standard - 24 VAC

C = CLII 13.8 VDC

Size (Footprint)

A = 17.5 x 21.5

B = 21.0 x 21.5

C = 23.5 x 21.5

Cooling Size: Air Handler or Coil

0-9  = AH Coil - 1000 BTU’s (18, 24, 30, 36, 42, 48, 60)

Power Supply

1 = 208-230/1/60

Convertability

M = Multi-poise 4-way

F = Upflow Front Return, 3-way

T = 3-way

Air Handler

4  T  X  C  B  0   3 6    A   C   3   H   C   A   A

Series

T = Premium 

(Heat Pump or Convertible Coil)

C = Standard 

(Cooling Only)

Refrigerant Type

4 = R-410A

Coil Design

X  = Direct Expansion Evaporator Coil

Coil Feature

C = Cased A Coil

A = Uncased A Coil

F = Cased Horizontal Flat Coil

Coil Width (Cased/Uncased)

A = 14.5" /13.3"

B = 17.5" / 16.3"

C = 21.0" / 19.8"

D = 24.5" / 23.3"

H = 10.5"

Refrigerant Line Coupling

0 = Brazed

Nominal Capacity in 1000's (BTUH)
Major Design Change
Efficiency

C = Standard

S = Hi Efficiency (derived from 10 SEER products)

Refrigerant Control

3 = TXV - Non-Bleed

Coil Circuitry

H = Heat Pump

C = Cooling

Airflow Configuration

A = Upflow Only

U = Upflow / Downflow

H = Horizontal Only

C = Convertible - Upflow, Downflow, Left or Right Airflow

Minor Design Change
Service Digit - Not Orderable

Heat Pump/

Cooling Coils

Содержание XL20i 4TTZ0024A1

Страница 1: ...XL20i 4TTZ0024 036 048 060 with ComfortLink II and Charge Assist 2 3 4 5 Tons Split System Cooling Product Data PUB NO 22 1825 09 ...

Страница 2: ...nly two wire control connection CHARGE ASSIST fast accurate charging every time Glossy corrosion resistant finish Internal compressor high low pressure temperature protection Start kit standard 50 or 100 capacity modulation Compressor sump heat Electronic compressor control Liquid line filter drier Tarpaulin gray cabinet with anthracite gray top Low sound with advanced fan system and compressor so...

Страница 3: ...s 2 General Data 4 Product Specifications 4 A weighted Sound Power Level dB A 4 Accessory Description and Usage 5 ARI Standard Capacity Rating Conditions 5 Model Nomenclature 6 Electrical Data 7 Dimensions 10 Mechanical Specification Options 11 ...

Страница 4: ... Condition Mounting Kit BAYECMT023 BAYECMT004 BAYECMT004 BAYECMT004 Vertical Discharge Air Kit Base 4 BAYVDTA003 BAYVDTA004 BAYVDTA004 BAYVDTA004 Auto Charge Solenoid Kit BAYCAKT001 BAYCAKT001 BAYCAKT001 BAYCAKT001 24 Volt Wiring Harness BAYACHP024A BAYACHP024A BAYACHP024A BAYACHP024A Refrigerant Lineset 5 TAYREFLN7 TAYREFLN7 TAYREFLN3 TAYREFLN3 1 Certified in accordance with the Air Source Unitar...

Страница 5: ...he unit in cooling opera tion Standard Noise Rating number is at 95 F outdoor air Accessory Description and Usage 24 Volt Wiring Harness Used to wire a communicating outdoor unit to an existing 24 Volt indoor section Charge Assist Solenoid Kit fast accurate charging every time Rubber Isolators 5 large rubber donuts to isolate con densing unit from transmitting energy into mounting frame or pad Use...

Страница 6: ...ctronic Filter Draft Inducer Speeds 1 Single Speed 2 Two Speed V Variable Speed Gas Furnaces G A M 5 A 0 B 3 6 M 3 1 S A A Brand T Better G Good Product Type A Air Handler Product Tier 2 Good Entry Level Feature Set 4 Better Retail Replacement Mid Effy 5 Better Entry Level High Effy Multi Speed 7 Best Retail Replacement High Effy Variable Speed 8 Best Retail Ultimate High Effy Variable Speed Major...

Страница 7: ...22 1825 09 7 4TTZ0024 4TTZ0036 4TTZ0048 4TTZ0060 Electrical Data Schematic Diagrams SEE LEGEND ...

Страница 8: ...8 22 1825 09 Electrical Data Schematic Diagrams SEE LEGEND Printed from D155834P01 Rev 00 4TTZ0024 4TTZ0036 4TTZ0048 4TTZ0060 ...

Страница 9: ...22 1825 09 9 LEGEND SYMBOLS Schematic Diagrams Electrical Data ...

Страница 10: ... dimensions are in MM Inches MODELS BASE A B C D E F G H J K 4TTZ0024A 4 1369 53 7 8 946 37 1 4 870 34 1 4 5 8 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 1035 40 3 4 4TTZ0036B 4TTZ0048B 4TTZ0060A 4 1369 53 7 8 946 37 1 4 870 34 1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 1035 40 3 4 ...

Страница 11: ...t on all other panels Corrosion and weather proof CMBP G30 DuraTuff base Refrigerant Controls Refrigeration system controls include condenser fan compressor contactor and high and low pressure switches High and low pressure controls are inherent to the compressor A factory installed liquid line drier is standard Compressor Two Climatuff compressors deliver 50 or 100 capacity modulation and feature...

Страница 12: ...Trane www trane com 04 12 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice ...