background image

 

22-1825-09

Product Specifications

Model No. 

1

 

4TTZ0024A1 4TTZ0036B1 4TTZ0048B1 4TTZ0060A1

Electrical Data V/Ph/Hz

 

2

 

200/230/1/60 208/230/1/60 200/230/1/60 200/230/1/60

Min Cir Ampacity 

14 

19 

26 

31

Max Fuse Size (Amps) 

20 

30 

40 

50

Compressors 

2 - CLIMATUFF

®

 

2 - CLIMATUFF

®

 

2 - CLIMATUFF

®

 

2 - CLIMATUFF

®

RL AMPS - LR AMPS 

8.7 - 58 

13.2 - 60.0 

18.6 - 93.4 

22.8 - 128.7

Outdoor Fan FL Amps 

2.80 

2.80 

2.80 

2.80

Fan 

HP 

1/3 1/3 1/3 1/3

Fan Dia (inches) 

27.5 

27.6 

27.6 

27.6

Coil 

Spine Fin™ 

Spine Fin™ 

Spine Fin™ 

Spine Fin™

Refrigerant R-410A 

10/10-LB/OZ 

10/8-LB/OZ 

15/7-LB/OZ 

13/15-LB/OZ

Line Size - (in.) O.D. Gas

 

3

 

3/4 3/4 7/8 7/8

Line Size - (in.) O.D. Liquid

 

3

 

3/8 3/8 3/8 3/8

Dimensions H x W x D (Crated)  57.4 x 35.1 x 38.7 

57.4 x 35.1 x 38.7 

57.4 x 35.1 x 38.7 

57.4 x 35.1 x 38.7

Weight - Shipping 

385 

385 

470 

470

Weight - Net 

335 

335 

420 

420

Start 

Components 

YES YES YES YES

Sound 

Enclosure 

YES YES YES YES

Compressor Sump Heat 

YES 

YES 

YES 

YES

Optional Accessories: 

4

Rubber Isolator Kit 

BAYISLT101 

BAYISLT101 

BAYISLT101 

BAYISLT101

Snow Leg - Base & Cap 4" High 

BAYLEGS002 

BAYLEGS002 

BAYLEGS002 

BAYLEGS002

Snow Leg - 4" Extension 

BAYLEGS003 

BAYLEGS003 

BAYLEGS003 

BAYLEGS003

Extreme Condition Mounting Kit 

BAYECMT023 

BAYECMT004 

BAYECMT004 

BAYECMT004

Vertical Discharge Air Kit Base 4 

BAYVDTA003 

BAYVDTA004 

BAYVDTA004 

BAYVDTA004

Auto Charge Solenoid Kit 

BAYCAKT001 

BAYCAKT001 

BAYCAKT001 

BAYCAKT001

24 

Volt 

Wiring 

Harness 

BAYACHP024A BAYACHP024A BAYACHP024A BAYACHP024A

Refrigerant Lineset

 

5

 

TAYREFLN7* TAYREFLN7* TAYREFLN3* TAYREFLN3*

1

  Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.

2

  Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.

3

  Standard line lengths - 80'. Standard lift - 25' Suction and Liquid line.

 

For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0

. (

denotes latest revision) 

4

  For accessory description and usage, see page 5. 

5

  * = 15, 20, 25, 30, 40 and 50 foot lineset available.

General 

Data

Low Stage 

Overall

High Stage 

Overall

63

125

250

500

1000

2000

4000

8000

4TTZ0024A1

59

68

44.8

54.4

60.5

57.7

61.4

61.9

55

49.1

4TTZ0036B1

67

72

50.8

55.3

64.6

67.8

64.3

63.2

57.6

51.5

4TTZ0048B1

68

76

51.3

56

68.3

71.3

65.6

69

58.9

49.6

4TTZ0060A1

70

76

51.4

59.8

67.3

68

69.6

70.1

61

51.5

Note: Tested in accordance with ARI Standard 270.95. (Not listed with ARI)

A-weighted Sound Power Level [dB(A)]

MODEL

 SOUND POWER 

LEVEL [dB(A)]

  A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)]  High Stage

Содержание XL20i 4TTZ0024A1

Страница 1: ...XL20i 4TTZ0024 036 048 060 with ComfortLink II and Charge Assist 2 3 4 5 Tons Split System Cooling Product Data PUB NO 22 1825 09 ...

Страница 2: ...nly two wire control connection CHARGE ASSIST fast accurate charging every time Glossy corrosion resistant finish Internal compressor high low pressure temperature protection Start kit standard 50 or 100 capacity modulation Compressor sump heat Electronic compressor control Liquid line filter drier Tarpaulin gray cabinet with anthracite gray top Low sound with advanced fan system and compressor so...

Страница 3: ...s 2 General Data 4 Product Specifications 4 A weighted Sound Power Level dB A 4 Accessory Description and Usage 5 ARI Standard Capacity Rating Conditions 5 Model Nomenclature 6 Electrical Data 7 Dimensions 10 Mechanical Specification Options 11 ...

Страница 4: ... Condition Mounting Kit BAYECMT023 BAYECMT004 BAYECMT004 BAYECMT004 Vertical Discharge Air Kit Base 4 BAYVDTA003 BAYVDTA004 BAYVDTA004 BAYVDTA004 Auto Charge Solenoid Kit BAYCAKT001 BAYCAKT001 BAYCAKT001 BAYCAKT001 24 Volt Wiring Harness BAYACHP024A BAYACHP024A BAYACHP024A BAYACHP024A Refrigerant Lineset 5 TAYREFLN7 TAYREFLN7 TAYREFLN3 TAYREFLN3 1 Certified in accordance with the Air Source Unitar...

Страница 5: ...he unit in cooling opera tion Standard Noise Rating number is at 95 F outdoor air Accessory Description and Usage 24 Volt Wiring Harness Used to wire a communicating outdoor unit to an existing 24 Volt indoor section Charge Assist Solenoid Kit fast accurate charging every time Rubber Isolators 5 large rubber donuts to isolate con densing unit from transmitting energy into mounting frame or pad Use...

Страница 6: ...ctronic Filter Draft Inducer Speeds 1 Single Speed 2 Two Speed V Variable Speed Gas Furnaces G A M 5 A 0 B 3 6 M 3 1 S A A Brand T Better G Good Product Type A Air Handler Product Tier 2 Good Entry Level Feature Set 4 Better Retail Replacement Mid Effy 5 Better Entry Level High Effy Multi Speed 7 Best Retail Replacement High Effy Variable Speed 8 Best Retail Ultimate High Effy Variable Speed Major...

Страница 7: ...22 1825 09 7 4TTZ0024 4TTZ0036 4TTZ0048 4TTZ0060 Electrical Data Schematic Diagrams SEE LEGEND ...

Страница 8: ...8 22 1825 09 Electrical Data Schematic Diagrams SEE LEGEND Printed from D155834P01 Rev 00 4TTZ0024 4TTZ0036 4TTZ0048 4TTZ0060 ...

Страница 9: ...22 1825 09 9 LEGEND SYMBOLS Schematic Diagrams Electrical Data ...

Страница 10: ... dimensions are in MM Inches MODELS BASE A B C D E F G H J K 4TTZ0024A 4 1369 53 7 8 946 37 1 4 870 34 1 4 5 8 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 1035 40 3 4 4TTZ0036B 4TTZ0048B 4TTZ0060A 4 1369 53 7 8 946 37 1 4 870 34 1 4 3 4 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 1035 40 3 4 ...

Страница 11: ...t on all other panels Corrosion and weather proof CMBP G30 DuraTuff base Refrigerant Controls Refrigeration system controls include condenser fan compressor contactor and high and low pressure switches High and low pressure controls are inherent to the compressor A factory installed liquid line drier is standard Compressor Two Climatuff compressors deliver 50 or 100 capacity modulation and feature...

Страница 12: ...Trane www trane com 04 12 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice ...

Отзывы: