Trane WCK024B1 Скачать руководство пользователя страница 6

Page  6

Sequence of Operation

and the unit will revert back to the compressor only heating mode
and then off. For 

emergency heat 

(use of supplementary electric

heat only), an emergency 

(EMERG)

 heat switch is provided

within the thermostat. When placed in the emergency heat
position, it will disable the compressor, bypass the outdoor
thermostats, if provided, and engage the supplementary electric
heaters and indoor fan.

DEMAND DEFROST OPERATION

During the heating cycle, the outdoor coil may require a defrost
cycle which is determined by the demand defrost control 

(DFC)

.

This control continuously measures the outdoor coil tempera-
ture 

(CBS)

 and the outdoor ambient temperature 

(ODS-B)

 and

calculates the difference or delta-T measurement. When the
calculated delta-T is met, the demand defrost control 

(DFC)

opens the circuit to the outdoor fan motor 

(ODM)

 and energizes

the switch-over valve 

(SOV)

, placing the unit in the cooling

mode to defrost the outdoor coil. The outdoor coil temperature
sensor 

(CBS) 

 terminates the defrost cycle, or times off after

twelve minutes in defrost, the 

(DFC)

 energizes the outdoor fan

motor 

(ODM) 

 and fifteen seconds later de-energizes the 

(SOV)

,

which returns the unit to the heating mode. Supplementary
electric heat, if provided, is brought on to control indoor tempera-
ture during the defrost cycle.

The following warning complies with State of California law, Proposition 65.

 ▲

WARNING:

This product contains

fiberglass wool insulation!

Fiberglass dust and ceramic

fibers are believed by the State of California to cause
cancer through inhalation. Glasswool fibers may also 
cause respiratory, skin, or eye irritation.

PRECAUTIONARY MEASURES 

 Avoid breathing fiberglass dust.

  Use a NIOSH approved dust/mist respirator.

  Avoid contact with the skin or eyes. Wear long-

    sleeved, loose-fitting clothing, gloves, and eye
    protection.

  Wash clothes separately from other clothing: rinse

    washer thoroughly.

  Operations such as sawing, blowing, tear-out, and

    spraying may generate fiber concentrations requiring
    additional respiratory protection. Use the appropriate
    NIOSH approved respirator in these situations.

FIRST AID MEASURES

Eye Contact     -

 Flush eyes with water to remove dust.

                               If symptoms persist, seek medical
                               attention.

Skin Contact   -

Wash affected areas gently with soap

                              and warm water after handling.

     

Important Product Information

Registering your products helps provide you with one of the strongest manufacturer limited warranties available. To register, go to
the manufacturer’s website or contact your dealer. You will need the serial number, model number, and installation date for each
product being registered. Your dealer may have included these on your invoice or can provide a list for you to use. Please take a
few moments to record the following information to ensure your product registration process is quick and easy:

Packaged Unit Serial Number_____________________________________________________
Packaged Unit Model Number_____________________________________________________
Date of Installation______________________________________________________________
Dealer________________________________________________________________________

Service Information

C

all your installing dealer if the unit is inoperative. Before you call, always check the following to be sure service is required:

a.

Be sure the main switch that supplies power to the unit is in the ON position.

b.

Replace any burned-out fuses or reset circuit breakers.

c.

Be sure the thermostat is properly set.

Service Phone_________________________________________________________________

Содержание WCK024B1

Страница 1: ...duct that are capable of conducting electri cal current are grounded If grounding wires screws straps clips nuts or washers used to complete a path to ground are removed for service they must be returned to their original position and properly fastened ALL phases of this installation must comply with NATIONAL STATE and LOCAL CODES These instructions do not purport to cover all variations in system...

Страница 2: ...s a make up air 5 Check the handling facilities to insure the safety of personnel and the unit s 6 CAUTION MUST BE TAKEN AT ALL TIMES TO AVOID PERSONAL INJURIES AND OR DAMAGE TO EQUIP MENT 7 The unit must be mounted level for proper drainage of defrost water through the holes in the base pan 8 Flexible duct connectors must be of a flame retardant mate rial All duct work outside of the structure mu...

Страница 3: ...2 32 70 72 32 70 72 139 70 308 441 17 3 8 413 16 1 8 WCK030B1 33 60 74 37 20 82 33 60 74 30 40 67 135 20 298 302 11 7 8 413 16 1 8 WCK024B1 38 60 85 34 92 77 29 02 64 32 20 71 135 20 298 0 413 16 1 8 TCK042B1 34 90 77 37 20 82 34 90 77 32 70 72 139 70 308 441 17 3 8 413 16 1 8 TCK036B1 33 60 74 36 70 81 33 60 74 30 80 68 134 70 297 441 17 3 8 413 16 1 8 TCK030B1 30 80 68 38 60 85 34 90 77 28 10 62...

Страница 4: ...e positioned on a pad the size of the unit or larger The unit must be level on the pad The pad must not come in contact with the structure Be sure the outdoor portion of the supply and return air ducts are as short as possible Proceed with the installation as follows 1 Place the unit on the pad 2 Attach the supply and return air ducts to the unit 3 Insulate any ductwork outside of the structure wi...

Страница 5: ...sition causing continu ous evaporator indoor fan operation or the AUTO position causing fan operation to coincide with heating or cooling run cycles Continuous fan mode during cooling operation may not be appropriate in humid climates If the indoor air exceeds 60 relative humidity or simply feels uncomfortably humid it is recommended that the fan only be used in the AUTO mode COOLING MODE NOTE TSH...

Страница 6: ...Use a NIOSH approved dust mist respirator Avoid contact with the skin or eyes Wear long sleeved loose fitting clothing gloves and eye protection Wash clothes separately from other clothing rinse washer thoroughly Operations such as sawing blowing tear out and spraying may generate fiber concentrations requiring additional respiratory protection Use the appropriate NIOSH approved respirator in thes...

Страница 7: ...horoughly dry before re installing them in the unit Replace permanent filters annually if washing fails to clean them or if they show signs of deterioration Use the same type and size as was originally installed Outdoor Coil Unfiltered air circulated through the unit s outdoor coil can cause the coil s surface to become clogged with dust dirt etc To clean the coil stroke the coil surface with a so...

Страница 8: ...door ambi ent temperature with a sensor located outside the outdoor coil A second sensor located on the outdoor coil is used to measure the coil temperature The difference between the ambient and the colder coil temperature is the difference or delta T measurement This delta T measurement is representative of the operating state and relative capacity of the heat pump system By measuring the change...

Страница 9: ...sor 2 Does OD fan cycle off in defrost N Replace defrost control 3 Windy weather preventing normal termination 7 Defrost initiates on approximately 15 25 minute intervals Be sure OD coil is clean N Complete Check 2 1 Coil sensor open or reading a very high resistance Y Replace coil sensor 2 Ambient sensor reading less than normal N Complete Check 3 Y Replace ambient sensor 3 OD fan off in defrost ...

Страница 10: ...rate auto matically Operating Pressures After the unit has operated in the cooling mode for a short time install pressure gauges on the gauge ports of the discharge and suction line valves Check the suction and discharge pressures and compare them to the normal operating pressures provided in the unit s SERVICE FACTS Voltage Withthecompressoroperating checkthelinevoltageattheunit The voltage shoul...

Страница 11: ...ally this limited warranty will not apply unless the packaged unit is 1 installed by a licensed or qualified HVAC technician 2 applied and installed in accordance with the manufacturer s recommendations and its Installer s guide and 3 in compliance with all industry standards national state and local codes This limited warranty does not cover failure of your packaged unit if it is damaged while in...

Страница 12: ...ry or warehouse replacement parts for Warrantor s products covered under this warranty Warrantor shall not be obligated to pay for the cost of lost refrigerant No liability shall attach to Warrantor until products have been paid for and then liability shall be limited solely to the purchase price of the equipment under warranty shown to be defective This limited warranty does not apply if the pack...

Отзывы: