Trane Tracer Concierge BMTC015ABC012000 Скачать руководство пользователя страница 1

SAFETY WARNING

Only qualified personnel should install and service the equipment. The installation, 
starting up, and servicing of heating, ventilating, and air-conditioning equipment can 
be hazardous and requires specific knowledge and training. Improperly installed, 
adjusted or altered equipment by an unqualified person could result in death or 
serious injury. When working on the equipment, observe all precautions in the 
literature and on the tags, stickers, and labels that are attached to the equipment.

BAS-SVN141D-EN

September 2021

Model Numbers:

BMTC015ABC012000

BMTC030CBC012000

BMTC030ABC012000

BMTC015CAC012000

BMTC015CBC012000

BMTC030CAC012000

Installation Instructions

Tracer Concierge

®

 System for 

Small Buildings

Pre-Packaged Control Panel and Display

Содержание Tracer Concierge BMTC015ABC012000

Страница 1: ...red equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labels that are atta...

Страница 2: ...ditioning industry All technicians who handle refrigerants must be certified according to local rules For the USA the Federal Clean Air Act Section 608 sets forth the requirements for handling reclaim...

Страница 3: ...elow Before installing servicing this unit technicians MUST put on all PPE recommended for the work being undertaken ALWAYS refer to appropriate MSDS sheets and OSHA guidelines for proper PPE When wor...

Страница 4: ...he UC400 2H 2C and Air Fi Wireless for Non Trane RTUs 7 Step 4 Install the UC210 Bypass Damper and Air Fi Wireless 8 Step 5 Install Tracer Concierge System Panel 9 Step 6 Wire I O 13 Step 7 Mount the...

Страница 5: ...it 4 anchors 4 screws 15 devices 2 XM s No LON WCI plastic enclosure BMTC030CBC012000 System Controller with 30 device license XM30 Module XM32 Module Air Fi Wireless Communication Interface WCI mount...

Страница 6: ...VN03 EN Set the BCI R and WCI rotary address switch appropriately per the submittal Important Before plugging in the Air Fi card power down the rooftop controller per instructions in the installation...

Страница 7: ...RTU or Heat Pump X39641251 01B The point list below is for your convenience Note Ensure Air Fi Wireless and zone sensors are addressed per the submittal Table 2 Analog inputs Label Functions AI1 Zone...

Страница 8: ...can communicate on an Air Fi network On all WCS and WCI the GRP and NET are set at 1 and 1 When installing confirm that these remain at 1 and 1 On unit controllers such as rooftop units VAV boxes and...

Страница 9: ...each zone sensor Step 5 Install Tracer Concierge System Panel Important Do not power the display until instructed to do so in Installation Instructions Dimensions and Clearances Figure 1 shows the in...

Страница 10: ...on the mounting surface to accommodate the supplied 10 screws and or 10 wall anchors 2 Set aside the enclosure and drill the marked location holes for the screws Figure 7 External dimensions Table 6 O...

Страница 11: ...transformer voltage utilization range is 98 132 Vac 120 Vac nominal 1 Lock open the supply power disconnect switch 2 At the top right corner of the enclosure remove the knockout for 0 50 inch 13 mm c...

Страница 12: ...d the electrical circuit Attach the label to the cover plate Install Enclosure Door 1 Unpack the door and check for any missing or damaged parts 2 Position the door at a 90 degree angle from the enclo...

Страница 13: ...01 UI AO 1 Outside Air Temperature Thermistor XM30 01 UI AO 2 N A Not used XM30 01 UI AO 3 N A Not used XM30 01 UI AO 4 N A Not used XM32 02 BO1 XM32 Binary Output 1 Must be wired as dry contact used...

Страница 14: ...ible for any users that are allowed to make adjustments using the display 2 Disassemble the VESA mount 3 Install the wall section onto the wall 4 Install the display section of the VESA mount onto the...

Страница 15: ...Watch the controller go through its LED sequence ending with dancing dashes See Figure 13 for power button location Note The network automatically stays open 1 hour After each Air Fi Wireless module j...

Страница 16: ...isplay Setup 1 Power on the display by pressing the power button on the back of the display 2 Follow the steps in the Setup Wizard See the Tracer Concierge Installation Operation and Maintenance Guide...

Страница 17: ...t Verify System Controller Air Fi Wireless is addressed properly per the submittal and or the Air Fi Wireless Network Best Practice guide BAS SVX55 EN Verifythe EthernetCable for thecustomer s network...

Страница 18: ...ce Agency Listing and Compliance United States Compliance Enclosure and modules are UL Listed separately UL Listed UL 916 Energy Management Accessory Canadian Compliance Enclosure and modules are CUL...

Страница 19: ...BAS SVN141D EN 19 Notes...

Страница 20: ...d to using environmentally conscious print practices Trane by Trane Technologies NYSE TT a global climate innovator creates comfortable energy efficient indoor environments for commercial and resident...

Отзывы: