22
TK 56917-11-MM-EN
Diagnostic Procedures
Quick Troubleshooting Guide
***PLEASE NOTE***
These behaviors are normal operation of the EPJ Charger System:
The GFCI outlet lights to come on and turn off throughout the day.
Power at the outlet to be intermittent.
E05 & E25 codes to be present on the inverter display.
The User/driver can follow the following steps during their route if they have concerns the EPJ charging system is not
operating properly or is not charging the EPJ when connected to the GFCI:
1. Unplug EPJ from GFCI outlet.
2. Ensure all charging plugs/connections from charging source if accessible (7 way, stinger cord) are seated properly.
3. Idle power source (tractor/reefer) for at least 5 minutes.
4. Ensure GFCI outlet’s lights are on or flashing every 5 seconds, if not hold reset button for 5 seconds until you hear
and feel a click.
•
If you can’t get the outlet GFCI lights to light up or flash, notify your supporting maintenance people.
5. Ensure EPJ/equipment battery is not fully charged, if they are, the EPJ/equipment may not be calling for a charge
from the outlet.
6. Check for damaged cables, replace or bypass the damaged cables.
7. Plug in EPJ and see if it starts charging.
8. If EPJ is still not charging, notify your supporting maintenance people.
IMPORTANT NOTE
Depleting the EPJ battery and then trying to rapidly recharge it is not recommended.
The EPJ should be connected to GFCI while in route and between each stop to maintain the battery charge. This allows the majority of the
charging to occur when the truck is in route.