Trane XR202  Programmable Thermostat

SPECIFICATION DESCRIPTION

Product Models

TCONT202

Product

XR 202

Size

3-3/4”  x  6” x 1-1/8 (HxWxD)

Configurations

Heat / Cool

Maximum Number of Stages

1H, 1C

Operating Temperature

32°F to 105°F (0 to +41°C) / 90% RH Non Condensing

Shipping Temperature Range

-20 to 150°F (-29 to +65°C)

Input Power (DC)

Two 1.5V AA Alkaline

Input Power (AC)

20 - 30 VAC, NEC Class ll, 50/60 HZ

Wire Usage

18 AWG

System Modes

Heating, Cooling, Off

Fan Modes

Auto, On

Cooling Setpoint Temperature Range

45°F to 99°F, 1°F resolution

Heating Setpoint Temperature Range

45°F to 99°F, 1°F resolution

Temperature Display Range

32°F to 99°F, 1°F resolution

Minimum Cycle Off Time Delay

Compressor: 5 minutes, Indoor Heat; 1 minute

Terminal Load

1.0A per terminal, 1.5A maximum all terminals combined

Operating Ambient

32°F to +105°F (0° to +41°C) 

Shipping Temperature Range

-20°F to +150°F (29° to +65°C) 

RATED DIFFERENTIALS

FAST

MEDIUM

SLOW

Heat (@ 6°F/Hr)

0.5°F

0.75°F

1.9°F

Cool (@ 6°F/Hr)

0.9°F

1.2°F

1.7°F

THERMOSTAT APPLICATION GUIDE

Thermostat Applications

Maximum Stages Heat/Cool

Gas, Oil, Electric, (mV and 24V), Heat Only, Cool Only or Heat/Cool Systems

1/1

2.  Product Specifications

3.  General Information

3.1  Overview

The 202 is a programmable push button single stage 
thermostat with a 3.5’’ backlit display. The 202 features a 
scheduling mode that can operate a 7-day program, 5-1-1 
program or operate in a non-programmable mode.

3.2  Contents

— 1-Thermostat
— 1-Sub-base
—  2-Phillips slotted head mounting screws
—  2-Nylon Drywall Anchors
—  1-Installation Guide / User Guide

3.3  Accessories

Wall Cover Plate (BAYCOVR200A) 

4.  Installation

4.1  Location

The

 

202

 

is designed for installation in climate controlled living 

spaces. Place the unit in a central location with good circulation.
For proper temperature sensing, avoid exposing the

 

202 to heat 

radiated from lamps, sun light, fireplaces or any other radiant heat 
source.
Avoid locations close to windows, behind doors or alcoves with 
poor air circulation, adjoining outside walls, or doors that lead to 
the outside.
Select a location that prevents the 202 from being directly exposed 
to air currents from supply registers or ceiling fans.
Mount the Control on a section of interior wall that does not 
contain hot or cold water pipes or duct work.

Содержание TCONT202

Страница 1: ...his Document is customer property and is to remain with this unit These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with the i...

Страница 2: ...erty damage if the outdoor temperature is below 55 F DO NOT operate the cooling system Do not allow the compressor to run unless the compressor oil heaters have been operational for six hours and the...

Страница 3: ...GUIDE Thermostat Applications Maximum Stages Heat Cool Gas Oil Electric mV and 24V Heat Only Cool Only or Heat Cool Systems 1 1 2 Product Specifications 3 General Information 3 1 Overview The 202 is a...

Страница 4: ...s 4 3 Battery Location Figure 2 LevelingThermostat Leveling is for appearance only and will not affect thermostat operation Battery Location Premium AA alkaline batteries are required when C wire is n...

Страница 5: ...ard 2 X2 is required to energize aux heat during defrost Cooling with TAM7 TAM9 24V Mode Indoor Unit Outdoor Unit Thermostat Rc Rh O B Y G W C R G W1 B B Y0 Y Y1 O NOTES 1 Wire third party condensate...

Страница 6: ...is required to energize aux heat during defrost Heat Cool Package with Variable Speed Blower Thermostat Rc Rh O B Y G W C R G W1 B Y1 NOTES 1 Wire third party condensate overflow switches between Y o...

Страница 7: ...rd 2 X2 is required to energize aux heat during defrost Heat Cool Package Thermostat Rc Rh O B Y G W C R G W1 B Y1 NOTES 1 Wire third party condensate overflow switches between Y of the thermostat and...

Страница 8: ...005 NOTES 1 Wire third party condensate overflow switches between Y of the thermostat and Y1 of the airflow control board 2 X2 is required to energize aux heat during defrost Cooling with GAT2 GAM2 TE...

Страница 9: ...ange Air Filter set up a monthly reminder OFF 1 to 12 reminder time months OFF no filter reminder 99 Keypad Lock prevent unwanted changes to the thermostat OFF On disable buttons OFF all buttons are a...

Страница 10: ...indicator 6 Cancels Hold Returns to Programmed Schedule 15 Day of the week used when programming a schedule 7 Raises Temperature Setting 16 Permanent hold bypassing the schedule 8 Access Menu Options...

Страница 11: ...momentarily press the Hold button Hold will be displayed Use or to adjust the temperature The thermostat will hold the room temperature at the selected setting until you press Run to start program op...

Страница 12: ...ic Set System Switch to Cool and lower setpoint below room temperature Same procedures as diagnostic for No Heat condition except set the thermostat to Cool and lower the setpoint below the room tempe...

Отзывы: