SS-SVX11K-EN
77
Discharge Air Sensor (Honeywell 6RT3 or
Honeywell 8RT3)
Each unit ordered with variable air volume controls
(digit 9 in the model number) is shipped with a
Honeywell 6RT3 or 8RT3 discharge air sensor.
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o
p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
W
WA
AR
RN
NIIN
NG
G
P
Prro
op
pe
err F
Fiie
elld
d W
Wiirriin
ng
g a
an
nd
d G
Grro
ou
un
nd
diin
ng
g
R
Re
eq
qu
uiirre
ed
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w cco
od
de
e cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
sse
erriio
ou
uss iin
njju
urry
y..
A
Allll ffiie
elld
d w
wiirriin
ng
g M
MU
US
ST
T b
be
e p
pe
errffo
orrm
me
ed
d b
by
y q
qu
ua
alliiffiie
ed
d
p
pe
errsso
on
nn
ne
ell.. IIm
mp
prro
op
pe
errlly
y iin
nsstta
alllle
ed
d a
an
nd
d g
grro
ou
un
nd
de
ed
d
ffiie
elld
d w
wiirriin
ng
g p
po
osse
ess F
FIIR
RE
E a
an
nd
d E
EL
LE
EC
CT
TR
RO
OC
CU
UT
TIIO
ON
N
h
ha
azza
arrd
dss.. T
To
o a
av
vo
oiid
d tth
he
esse
e h
ha
azza
arrd
dss,, y
yo
ou
u M
MU
US
ST
T ffo
ollllo
ow
w
rre
eq
qu
uiirre
em
me
en
nttss ffo
orr ffiie
elld
d w
wiirriin
ng
g iin
nsstta
alllla
attiio
on
n a
an
nd
d
g
grro
ou
un
nd
diin
ng
g a
ass d
de
essccrriib
be
ed
d iin
n N
NE
EC
C a
an
nd
d y
yo
ou
urr llo
occa
all//
sstta
atte
e//n
na
attiio
on
na
all e
elle
eccttrriicca
all cco
od
de
ess..
Install sensor in a turbulent free area of discharge air
duct where it will provide accurate supply air sensing
figure below for installation and sensor dimensions.
Figure 52.
Discharge air sensor assembly
Mounting Holes
Insertion Hole
7/8” Dia.
VAV Discharge
Air Sensor
Airstream
Discharge Duct
Junction Box
Air Inlet Holes
1-3/4”
1-3/16”
1-3/16”
1-3/4”
13-5/8”
Sensor Dimensions
7/8”
The sensor serves two functions:
•
Sends supply air temperature data to Discharge Air
Controller as an analog input, to control the
economizer (if applicable) and cycling of
compressors
•
Low limit sensor for system when supply air
temperature reaches too high a delta T between
actual supply air temperature and supply air
temperature setpoint.
Before installing any connecting wiring, see drawings
in Dimensions and Weights chapter for electrical
access locations. Wire sensor per field connection
diagram, numbers 2307-9122 (for 20-60) and 2307-9144
(for 80-120). Shielded cable (Belden 8760 or equivalent)
must be used when wiring sensor to the terminal board
inside unit control panel.
Connect shielded cable to appropriate terminals on
terminal board (7TB7), in control panel.
Ground shield (at unit only) using ground screw in
customer 24 volt connection area as shown in field
connection diagram.
Suction Line Thermostat
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o
p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
Each unit ordered with variable air volume controls
(digit 9 in the model number) is shipped with a suction
line thermostat (6S63) that must be field installed.
Locate the thermostat close to the expansion valve
bulb on a slightly flattened portion of the suction line.
The thermostat must be securely fastened to the
suction line and a field provided thermoconductive
grease must be applied to the area to ensure good heat
transfer.
Before installing any connecting wiring, see drawings
in Dimensions and Weights chapter for electrical
access locations. Wire suction line thermostat per field
connection diagram, numbers 2307-9122 (for 20-60)
and 2307-9144 (for 80-120). See
(AC
Conductors) for wiring specifications.
Insulate the suction line, where the thermostat is
mounted, to isolate it from the surrounding air.
Содержание RAUJ-C20
Страница 6: ...6 SS SVX11K EN Wiring Diagrams 128 T Ta ab bl le e o of f C Co on nt te en nt ts s...
Страница 117: ...SS SVX11K EN 117 S St ta ar rt t U Up p...
Страница 129: ...SS SVX11K EN 129 N No ot te es s...
Страница 130: ...130 SS SVX11K EN N No ot te es s...
Страница 131: ...SS SVX11K EN 131 N No ot te es s...