background image

AMS-SVX02A-EN 

25

1

ON/OFF Button 

Press ON/OFF button to turn on the unit, and repress this 
button to turn off the unit. At the time of startup, the unit runs 
in the present setting.

2

Temperature (time) setting buttons 

Use this set of buttons to set and adjust temperature (or 
time). Press these two buttons at the same time to change the 
temperature unit (

/

ņ

).

3

Quick cooling/Quick heating function 

When the Quick cooling/Quick heating key of the wired 
controller of an indoor unit is pressed, repress to cancel.

Selection of timing function 

Press the Quick cooling/Quick heating key for 2s to enter the 
timing state. Select any one of the four functions: Timing on/
off, Timing off only, Timing on only, and Timing canceled. Turn 
on or turn off the unit according to the current set time.

4

PRI setting 

When pressing the PRI setting button of the wired controller of 
an indoor unit, the indoor unit is preferred, keep energy supply 
preferential, and repress to cancel.

View and setting of timing function  

Press the button for 2s to enter Set time view/setting, and 
view and display the current state, present time, timing on 
time, and timing off time in turn (24h system). Under each 
displaying state, press UP/DOWN button within 5s to adjust the 
temperature (time).

5

Fan speed setting button 

Select the fan speed in high/medium/low/auto mode

6

Swing function button  

Press this button once to enable the Swing function, press it 
again to disable this function.

7

Sleep function button 

8

Selection of operating mode button 

Press this button to enable the sleep function in present 
operating mode; repress it to shut down or cancel this 
function; after 8h, it may be canceled automatically. Cooling/
heating mode of this function is valid: after being canceled, 
reset the temperature and fan speed in sleep state.

9

Reset hole 

Press the Reset hole, zero the timing of dust fi ltration screen 
cleaning, do not display symbol of the screen, and accumulate 
the operating time of the air conditioner again.

10

Display of priority

This indoor unit is under the priority setting state or not

Wired Controller Instruction

11

Sleep function Display 

While operating in sleep mode, this animation displays

12 Display of operating in auto mode

13 Display of operating in fan mode

14 Display of operating in dry mode

15 Display of operating in heating or quick heating mode 

16 Display of operating in cooling or quick cooling mode

17 Display of time, timing function

When pressing the timing setting button, the 
corresponding time is displayed in turn: after fi nishing 
setting. Display the clock: display selection of timing in 
current operating mode. 

Display of fault code

If the unit needs stopping for repair or the safety 
protection device activates due to system failure, the 
fault or protection code is displayed in the time display 
are, and fl ashes. 

18 Display of set temperature

Display of the set temperature in present operating 
state

19 Display of the fan speed

Display the present fan speed selected in animation. 
Under the heating cold air protection state, the cold air 
protection is not displayed in animation.

20 Display of operating state of the compressor

When the compressor stops, display full idle state. In 
operating, display full-load state; in stop, no display. 
For the VF compressor, the operating frequency may 
be displayed.

21 Display of auxiliary heating

When the auxiliary heating operates, this display 
appears.

22 Display of defrosting

Display the system in defrosting mode.

23 Display of dust fi ltration screen

When dust fi ltration screen needs cleaning, this display 
appears.

24 Cooling mode setting button

25 Heating mode setting button

Содержание MWC518

Страница 1: ...Indoor Unit Installation Operation Manual Advanced Multi split System Cassette Indoor Unit MWC518 524 R410A 200061360200 April 2012 AMS SVX02A EN...

Страница 2: ...Unit Installation Site Selection and Attentions 8 Unit Installation 10 Installation Diagram 10 Panel Installation 14 Electrical Control Wiring 19 Electrical Wiring 19 Electrical Parameters 21 Electric...

Страница 3: ...ed on If user do not use the unit for a long term please cut off power supply and switch on the main power switch for 24 hours before operation When the indoor unit receives shutdown signal the fan wo...

Страница 4: ...f machine Otherwise the machine may fall and cause personnel injury or death Install the drainage pipe in accordance with this manual to ensure smooth water flow Besides you should also take measures...

Страница 5: ...onnect with gas pipe water pipe lightning rod or phone line Switch off the unit after 5 minutes running at least otherwise it may reduce the unit service life Children operating air conditioning unit...

Страница 6: ...acity 18 24 Digit 7 Design serial no M Free split indoor unit inverter system with electronic expansion valve Digit 8 Power supply type M 220 240V 50Hz 1PH Digit 9 Electric heater N Non electric heate...

Страница 7: ...ge device built in type Discharge condensate water from the indoor unit in cooling mode Drainage pipe Air de ector In the air outlet Connecting pipe Air outlet Air strainer and puri er In the air inle...

Страница 8: ...onment with corrosive gas heavy dust salt mist and oil smoke can not be the installation site Attention Following locations may cause the air conditioning unit fault If you have to select this kind of...

Страница 9: ...s not used for x or it may cause electric shock Earth resistance complies with national standards GB17790 User is responsible for providing reliable earthing terminal Pease do not connect earth wire t...

Страница 10: ...t to outdoor unit 5 Ensure enough space for repair and maintenance 6 The distance between indoor unit and ground is 1 800mm at least Check hoist screw installation site if support 4 times of the unit...

Страница 11: ...tact local Trane authorized service center before installation When the unit installed by non authorized service center is failure we can not resolve it in time for business relations Ceiling hatch di...

Страница 12: ...ing Installation paperboard 2 Review installation paperboard for ceiling hatch dimension There is a mark in the installation paperboard indicating ceiling hatch centre Fix the installation paperboard...

Страница 13: ...sory Nut provided on site Hanger bracket Tighten double nut Washer accessory Fix the screw at the corner of outlet pipe at the drainage tank corner Center of the ceiling hatch Installation paperboard...

Страница 14: ...at the main hook temporarily air de ector motor wires can not be involved in sealing materials Torque the 4 hexagonal screws below the hook to 15mm the panel will be lifted later As shown in fig adjus...

Страница 15: ...panel after tightening screws please 2 adjust the indoor unit height again as shown in g 8 No seams Without affecting the indoor unit lifting and drainage pipe are prerequisites for adjusting the heig...

Страница 16: ...leakage and take heat insulation measures Wrap joints of air pipe and air collector pipe insulating sleeve with the sponge Apply refrigerating engine oil Torque wrench Wrench Pipe joint Liquid inlet...

Страница 17: ...To allow the drainage hose not to bend a distance of 1 1 5m at least shall be maintained between hangers Wrong 1 1 5m Correct gradient above 1 100 Figure 11 Use the supplied drainage hose and clamp In...

Страница 18: ...uent drainage pipe Less than 75mm Less than 500mm Selected confluent drainage pipe to be sized to operating capacity to the Figure 14 unit Check if the water drains smoothly at the end of installation...

Страница 19: ...them with a cable clip respectively Wiring according to indoor circuit diagram Fix the cable clip after completed Wrap the wire with small sponge it is necessary for prevent condensation formation Pre...

Страница 20: ...use special power wires with leakage and air switches for 3 overloading Air conditioning unit must be earthed to prevent damage caused by failure of insulation 4 All wirings must use crimp terminal o...

Страница 21: ...he rubber ring 2 Insert the wired controller signal wire into 4 pin socket of indoor unit circuit board 3 Tie and x the wired controller signal wire with cable tie 4 Attention Please pay close attenti...

Страница 22: ...ent temperature sensing bulb Outlet temperature sensing bulb Inlet temperature sensing bulb Midpoint temperature sensing bulb CN18 CN8 CN9 0 4 RT4 CN12 CN13 3 RT2 2 CN19 1 RT1 Power supply CN2 3Yellow...

Страница 23: ...ed gear selection According to indoor unit connecting pipe length correct fan speed through DIP There are 8 DIP switches for SW2 at indoor unit control board and S7 decides indoor unit fan speed gear...

Страница 24: ...he diagram is just for reference the actual display may be different 1 When you press a button there may be no action since non corresponding function 2 Please clean the air strainer in accordance wit...

Страница 25: ...is valid after being canceled reset the temperature and fan speed in sleep state 9 Reset hole Press the Reset hole zero the timing of dust ltration screen cleaning do not display symbol of the screen...

Страница 26: ...indoor unit Poor cooling performance 1 Air strainer is dirty or blocked 2 Heat source or too much people in the room 3 The door or window is open 4 Barriers in air outlet inlet 5 High setting tempera...

Страница 27: ...dusty environment air strainer s cleaning frequency shall be increased generally clean it every two weeks Check before the beginning of service season Check that both inlet and outlet of the unit are...

Страница 28: ...2012 New Trane www trane com For more information contact your localTrane office or e mail us at comfort trane com Trane has a policy of continuous product and product data improvement and reserves t...

Отзывы: