Safety Precautions

Read the following warnings and cautions
carefully before operating the system and
use it correctly.

This manual classifies the precautions to the
user into two categories on the right.
Be sure to follow all as they are all important
to ensure safety.

After reading this manual, keep it in a place
easily accessible to the user for future
reference.

WARNING

Do not expose your body to the cool air for a long time, do not cool  the room too much.

It will affect your physical conditions and cause health problems.

Do not put a finger, a rod or other objects into the air outlet or inlet.

As the fan is rotating at a high speed, it will cause injury.

Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself.

Incorrect work will cause electric shocks, fire etc. For repairs and reinstallation, consult the dealer
where you bought the air conditioner.

If anything abnormal such as a burning smell occurs, stop the operation immediately and turn the breaker OFF.

Continued abnormal operation will cause troubles, electric shocks, fire etc. If anything is
abnormal, consult the dealer where you bought the air conditioner.

If the air conditioner is not cooling or heating properly, the refrigerant may be leaking, so
see the dealer where the unit was purchased. Check with a qualified repairman before
attempting any repairs, which might accompany addition of refrigerant.

The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some reason any
refrigerant happens to leak into the room, make sure it does not come in contact with any flame, such as fan
heaters, kerosene heaters, or gas ranges, as this may result noxious substances being generated.

CAUTION

Do not use the air conditioner for preservation purposes.

Do not use it for preserving precision instruments, foods, plants, animals, works of fine arts etc.
Performance or quality may deteriorate and animal or plant life may be shorter.

Do not operate the air conditioner with a wet hand.

It may cause an electric shock.

Ventilate the room from time to time.

Be careful especially when using a burning appliance in the same room. Insufficient ventilation
may cause shortage of oxygen.

Before cleaning, be sure to stop the operation and turn the breaker OFF.

As a fan is rotating at a high speed, cleaning during operation may cause injury.

After a long use, check the unit stand and fittings for damage.

The unit may drop and cause injury if damage is left unrepaired.

Do not stand or sit on the outdoor unit. Do not place any object on the unit.

The object or the person may fall down or drop, causing injury.

Do not pull at the conduit or hang anything on it.

Otherwise it will cause fire or electric shock.

 WARNING

Failure to follow a warning is very likely
to result in such grave consequences as
death or serious injury.

 CAUTION

Failure to follow a caution may result in
serious  injury or property damage, and
in certain conditions, may result in a
grave consequence.

01̲EN̲3P102561-6F.p65

03/06/04, 9:22

Page 4

Adobe PageMaker 6.5J/Win

Содержание MCW509AMUA0

Страница 1: ...Owner Manual Split System High Wall mounted type MCW509AMUA0 MCW512AMUA0 MCW518AMUA0 MCW524AMUA0...

Страница 2: ...2...

Страница 3: ...ction Adjusting the horizontal blade flap 12 Adjusting the vertical blade louvre 13 POWERFUL Operation 13 Timer Operation OFF TIMER operation 14 ON TIMER operation 14 CARE Care and Cleaning Cleaning t...

Страница 4: ...of refrigerant The refrigerant used in the air conditioner is safe Although leaks should not occur if for some reason any refrigerant happens to leak into the room make sure it does not come in contac...

Страница 5: ...n it Falling or tumbling may result in injury Depending on the usage environment water may leak from the air conditioner If this happens contact your Trane Dealer Installation WARNING Do not attempt t...

Страница 6: ...neighbours from noises For installation choose a place as described below A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration A place from wher...

Страница 7: ...ensor It senses the air temperature around the unit Mode COOL Air flow rate AUTO Temperature setting 72 F Push this button once to start operation Push once again to stop it This button is useful when...

Страница 8: ...Air purifying filters are attached to the inside of the air filters Air filter Room temperature sensor It senses the air temperature around the unit It receives signals from the remote controller Whe...

Страница 9: ...tting SWING button See page 12 It changes the temperature setting Display It displays the current settings In this illustration each section is shown with all its displays ON for the purpose of explan...

Страница 10: ...res on the display to flash Set the clock at this point 1 2 3 Operating the remote controller To use the remote controller aim the transmitter at the indoor unit If there is anything to block signals...

Страница 11: ...n if the system is not operating Turn off the main power supply switch for saving energy If you are not going to use the air conditioner for a long period for example in spring or autumn turn the brea...

Страница 12: ...lable DRY or FAN mode The air flow rate setting is not variable Press FAN ON OFF To change the air flow direction See page 12 Adjusting the Air Flow Direction You can adjust the air flow direction to...

Страница 13: ...ation In COOL mode To maximize the cooling effect the capacity of outdoor unit must be increased and the air flow rate be fixed to the maximum setting The temperature and air flow settings are not var...

Страница 14: ...e timer Then the TIMER lamp goes off Check that the clock is correct If not set the clock to the present time See page 11 1 is displayed blinks Previous time setting appears on display 2 Press TIMER u...

Страница 15: ...the point in the middle Push the grille at the 3 points indicated by 1 3 2 Cleaning the air filters MCW518AMUA0 MCW524AMUA0 Open the front grille Hold the grille by the tabs on the two sides and lift...

Страница 16: ...this state Push the grille at the 3 points two at both sides and in the middle Open the front grille Hold the grille by the tabs on the two sides and lift it until it stops with a click Care and Clean...

Страница 17: ...is is the case Check MCW518AMUA0 MCW524AMUA0 Care and Cleaning Clean the front grille You may wipe it with a soft cloth soaked in water Only neutral detergent may be used You may wash the grille with...

Страница 18: ...ondenses into water on the cool surface of outdoor unit piping and drips This happens when the air in the room is cooled into mist by the cold air flow during cooling operation This happens when smell...

Страница 19: ...s the temperature setting appropriate Are the windows and doors closed Are the air flow rate and the air direction set appropriately Are the air filters clean Is there anything to block the air inlet...

Страница 20: ...ails to work properly There is a burning smell Water leaks from the indoor unit Turn the breaker OFF and call the dealer After a power failure The air conditioner automatically resumes operation in ab...

Страница 21: ......

Страница 22: ......

Страница 23: ...comfort trane com www trane com Literature Order Number SSA SVD01B EN File Number SV UN SVD01B EN 0904 Supersedes SV UN SVD01A EN 0403 Stocking Location Trane has a policy of continuous product and p...

Отзывы: