RT-SVX056D-GB
17
IH 021
IH 031
IH 041
IH 051
IH 061
IH 071
Oversized
Type
Plug Fans
Plug Fans
Plug Fans
Plug Fans
Plug Fans
Plug Fans
Model
#
K3G450PA2371
K3G450PA2371
K3G500PA2371
K3G500PB3301
K3G500PB3301
K3G500PB3301
Minimum Airflow
m3/h
3088
4632
6176
7720
9264
9573
Nominal Airflow
m3/h
3860
5790
7720
9650
11580
11966
Maximal Airflow
m3/h
5018
7527
10036
12545
15054
15556
Number
#
1
1
1
1
1
1
Diameter
mm
450
450
500
500
500
500
Drive Type
#
EC Motors
EC Motors
EC Motors
EC Motors
EC Motors
EC Motors
Motor Power (Eurovent condition)
kW
0.220
0.452
0.691
1.226
1.848
1.998
Motor Max Amps per fan
A
4.7
4.7
5.3
9
9
9
Motor RPM at nominal flow rate
RPM
831
1145
1148
1408
1650
1699
Available Static Pressure at nominal flow rate
Pa
500
500
500
500
500
500
Outdoor Fan
Standard Ambient
Type
Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC Axial / Below / AC
Model
#
A8D800A10105
A8D800A10105
A8D800A10105
A8D800A10105
A8D800A10105
A8D800A10105
Nominal Airflow / ckt
m3/h
14566
14560
24910
24897
24884
24879
Number of fan / ckt
#
1
1
2
2
2
2
Diameter
mm
800
800
800
800
800
800
Motor Power per fan
kW
0.89
0.89
0.89
0.89
0.89
0.89
Motor Max Amps per fan
A
2.22
2.22
2.22
2.22
2.22
2.22
Motor RPM
rpm
686
686
686
686
686
686
Low Ambient
Type
Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC Axial / Below / EC
Model
#
A3G800AS3905
A3G800AS3905
A3G800AS3905
A3G800AS3905
A3G800AS3905
A3G800AS3905
Nominal Airflow
m3/h
14566
14560
24910
24897
24884
24879
Number
#
1
1
2
2
2
2
Diameter
mm
800
800
800
800
800
800
Motor Power per fan
kW
1.95
1.95
1.95
1.95
1.95
1.95
Motor Max Amps per fan
A
3
3
3
3
3
3
Motor RPM
rpm
686
686
686
686
686
686
Physical Data for Standard Unit (4)
Length
mm
2830
2830
2830
2830
2830
2830
Width
mm
2250
2250
2250
2250
2250
2250
Height
mm
1565
1565
1565
1565
1565
1565
Operating Weight (Without Auxiliary Heat)
kg
884
884
966
966
966
966
Shipping Weight (Without Auxiliary Heat)
kg
940
940
1022
1022
1022
1022
Options Extra Weight (4)
Hot Water Coil
kg
48
48
48
48
48
48
Electric Heater
kg
22
22
22
22
26
26
Gas Burner: modulating condensing
kg
76
76
76
76
90
90
Energy Recovery Module
kg
375
375
375
375
375
375
Exhaust Fan (EC)
kg
24
24
24
24
24
24
Exhaust Fan (AC)
kg
81
81
81
81
81
81
Return Roofcurb Down
kg
380
380
380
380
390
390
Return Roofcurb Horizontal
kg
280
280
280
280
290
290
Downflow Adjustable Roofcurb
kg
150
150
150
150
150
150
Multidirectional Roofcurb
kg
190
190
190
190
190
190
Energy Recovery Module (ERM)
Max Exhaust Air @ ESP=400Pa
m3/h
9500
9500
9500
9500
9500
9500
Max Fresh Air @ Wheel PD=300Pa
m3/h
18000
18000
18000
18000
18000
18000
Min Wheel Airflow
m3/h
2500
2500
2500
2500
2500
2500
Exchanger Wheel Diameter
mm
1200
1200
1200
1200
1200
1200
Exhaust Air Fan Diameter
mm
400
400
400
400
400
400
Exhaust Air Fan Motor Power
kW
3.4
3.4
3.4
3.4
3.4
3.4
Length x Width x Height
mm
1750x1175x1575 1750x1175x1575 1750x1175x1575
1750x1175x1575
1750x1175x1575
1750x1175x1575
Weight
kg
396
396
396
396
396
396
Gas Burner
Gas burner type - modulating condensing
#
PCH045
PCH045
PCH045
PCH045
PCH065
PCH065
Thermal output (Hi) [Min-Max]
kW
8,50 - 42,0
8,50 - 42,0
8,50 - 42,0
8,50 - 42,0
12,40 - 65,0
12,40 - 65,0
Useful heat output [Min-Max]
kW
8,97 - 40,45
8,97 - 40,45
8,97 - 40,45
8,97 - 40,45
13,40 - 62,93
13,40 - 62,93
Gas Flow [Min-Max] (5)
m3/h
0,90 - 4,44
0,90 - 4,44
0,90 - 4,44
0,90 - 4,44
1,31 - 6,88
1,31 - 6,88
Flue gas emission
Carbon monoxide - CO - (0% of O2) (5)
ppm
<5
<5
<5
<5
<5
<5
Nitrogen oxides - NOx - (0% of O2) (5)
mg/KWh
33
33
33
33
39
39
CO2 max (5)
%
9.1
9.1
9.1
9.1
9.1
9.1
Gas Connection Pipe Diameter
#
UNI/ISO 228/1
G3/4"
UNI/ISO 228/1
G3/4"
UNI/ISO 228/1
G3/4"
UNI/ISO 228/1
G3/4"
"UNI/ISO 228/1
G3/4"""
"UNI/ISO 228/1
G3/4"""
Table 4
–
AFD (continued)
(1) Indicative performances. For detailled performances, consult order write up (OWU).
(2) Under 400V/50Hz/3Ph.
(3) Electrical & system data are indicative and subject to change without notice. Please refer to unit nameplate data.
(4) Indicative data. For details consult lifting and handling instructions in document package shipped with the unit.
(5) Value referenced to Gas G20 - for other refer to burner IOM manual.
(6) OIL058E or OIL057E are European reference for POE oil and can be mixed in any proportion with OIL00078 or OIL00080 (same oil with US reference on compressor
nameplate).
(7) The ERM data is only for Digit -18 R.
IH General Data