background image

16

SSC-SVN001H-EN

Fig. 10 - Wiring Diagram - Start - CXPA 050 to 500 

Wiring 

Diagram

POWER SUPPLY

3 PHASES

TERMINAL STRIP

M

O

TO

R

C

O

N

TA

C

TO

R

EV

AP

O

R

AT

O

R

ST

AT

U

S

3-PHASE

CAPACITOR

(OPTIONAL)

EVAPORATOR

OPTIONALSTART

CAPACITOR

WIRING WHEN CAPACITOR IS

USED

BY CLIENT (CONTRACTOR)
BY TRANE
START PANEL CONTROL

TERMINALS

Содержание CXPA 050

Страница 1: ...quipment The installation starting up and servicing of heating ventilating and air conditioning equipment can be hazardous and requires specific knowledge and training Improperly installed adjusted or...

Страница 2: ...must be met during the transportation of refrigerant con tainers Recycling equipment should be used to minimize emissions during the transfer of refrigerant gas Alwa ys use methods that generate the...

Страница 3: ...a 4 Unit Inspection 6 Transport and Handling 7 Installation Procedures 8 Refrigeration Piping Interconnection 9 Operation 10 Maintenance Procedures 11 Periodical Preventive Maintenance 13 Electrical D...

Страница 4: ...356 356 x 356 356 x 356 381 x 778 381 x 778 305 x 508 305 x 508 381 x 508 457 x 508 457 x 508 483 x 686 Qty 1 2 1 3 3 8 4 4 4 4 12 12 8 10 5 10 Size 2 mm 508 x 635 356 x 508 356 x 508 305 x 778 305 x...

Страница 5: ...uantity 1 1 1 1 2 1 1 Propellerdiameter mm 22 26 30 30 26 35 35 Air Flow m3 h 7234 9180 11900 11900 18360 23800 30600 Pipe Diameters Numberof Circuits 1 1 1 2 1 2 1 2 1 2 Liquid Line in 1 2 1 2 5 8 1...

Страница 6: ...the condensate tray Allow minimum recommended cle arances for routine maintenance and service see page 20 The same clearances should be observed in case of several units to gether or condensing units...

Страница 7: ...gure 4 The module packaging material should only be removed after the unit is placed at the final mounting location Take proper care while handling the equipment 5 During transportation do not swing t...

Страница 8: ...ghtened Component Review Fan and motor shafts are paral lel Fan and motor sheaves are alig ned The fan belt tension is correct Rotors can be freely turned Locking screws bearing screws and sheaves are...

Страница 9: ...G DIAGRAM DRIER FILTER AND LIQUID SIGHT GLASS CAUTION Do not operate the unit without air filters MOUNTING DIAGRAM DRIER FILTER DRIER FILTER 1 2 AND 5 8 THREAD WELDED DRIER FILTER 5 8 7 8 1 1 8 Welded...

Страница 10: ...aximum distance recommended distance between units 46 m difference in levels between units 18 m Calculated distance considering equivalent length of connection elements For distances higher than the r...

Страница 11: ...Do not operate the unit without air filters Tab 05 Nominal load of refrigerant R410a and oil load Condensing Units Onix Indoor Outdoor R410a kg Oil L Ckt1 Ckt2 Ckt1 Ckt2 CXPA050 1C TRAE050 1C 2 99 1 5...

Страница 12: ...ision of the distan ce between sheaves by 64 inches If a tension meter is not available press the belt with the thumb The belt should present a deflection of approx 10 mm If replacement for a new one...

Страница 13: ...ading sheet can be a precious tool for service personnel Quarterly Maintenance Perform all monthly maintenance tasks Check bearing and shave fixing screws and adjust then if requi red Clean the conden...

Страница 14: ...8 50 22 00 30 00 220 V CNO A 1 54 2 26 2 84 3 85 5 18 7 94 8 88 10 96 13 20 16 16 20 64 25 12 29 76 42 08 51 68 59 20 79 36 CMO A 1 92 2 82 3 55 4 81 6 48 9 93 11 10 13 70 16 50 20 20 25 80 31 40 37 2...

Страница 15: ...at least 10 C above the refrigerant tempera ture in the suction side low pressu re side This requirement ensures that the refrigerant will not be retai ned in the compressor crankcase Tests can be don...

Страница 16: ...PA 050 to 500 Wiring Diagram POWER SUPPLY 3 PHASES TERMINAL STRIP MOTOR CONTACTOR EVAPORATOR STATUS 3 PHASE CAPACITOR OPTIONAL EVAPORATOR OPTIONALSTART CAPACITOR WIRING WHEN CAPACITOR IS USED BYCLIENT...

Страница 17: ...oil Fig 11 Dimensional Data Fan Module 050 to 100 Fig 12a Vertical Discharge Fig 12c Downflow Discharge Fig 12b Horizontal Discharge Fig 13 Dimensional Data Coil Module 050 to 100 Unit mm Unit mm Mode...

Страница 18: ...rical Panel FRONT FRONT FILTERS DRAIN external Dimensional Data Fig 14 Dimensional Data Fan Module 125 and 150 Fig 16 Dimensional Data Coil Module 125 and 150 Fig 15a Vertical Discharge Fig 15b Horizo...

Страница 19: ...6 F 381 457 457 G 296 5 278 5 315 5 Model 200 250 300 E 478 433 561 F 376 452 452 G 294 276 313 H 407 485 485 Dimensional Data Fig 17 Dimensional Data Fan Module 200 to 300 Fig 19 Dimensional Data Coi...

Страница 20: ...F 291 5 235 235 Model 350 400 500 D 478 561 561 E 379 311 311 F 289 232 5 232 5 G 401 423 423 H 407 485 485 Fig 20 Dimensional Data Fan Module 350 to 500 Fig 22 Dimensional Data Coil Module 350 to 500...

Страница 21: ...1 5 8 1 5 8 1 5 8 1 5 8 2 1 8 L1 Liquid 1 2 1 2 1 2 5 8 7 8 7 8 7 8 7 8 1 1 8 Circuit 2 Ton 5 5 7 5 10 10 15 15 20 25 S2 Suction 7 8 7 8 1 1 8 1 3 8 1 3 8 1 5 8 1 5 8 1 5 8 2 1 8 L2 Liquid 1 2 1 2 1...

Страница 22: ...2770 2770 2770 B 970 1130 1320 1160 1160 1340 1600 1600 1600 1800 1800 C 510 590 690 830 830 1000 1100 1100 1100 1220 1220 D 510 590 585 770 940 880 1100 1100 1100 1220 1490 Model 050 075 100 125 150...

Страница 23: ...0 200 250 300 350 400 500 A 980 1165 1450 1500 1500 1950 1900 2230 2800 2800 2800 B 405 485 580 500 500 590 720 720 720 820 820 C 1010 1195 1480 1530 1530 1980 1930 2260 2830 2830 2830 Modelo 050 075...

Страница 24: ...irculation Fan and Coil Modules Vertical Cabinets Fig 30 Suggested Clearances for Maintenance and Air Circulation Fan and Coil Modules Horizontal Cabinets Vertical Cabinet 1200 1200 Free Discharge Fre...

Страница 25: ...SSC SVN001H EN 25 Dimensional Data TRAE Fig 31 Dimensions Condensing Units TRAE 050 Fig 32 Dimensions Condensing Units TRAE 075...

Страница 26: ...26 SSC SVN001H EN Fig 33 Dimensions Condensing Units TRAE 100 1 circuit Fig 34 Dimensions Condensing Units TRAE 100 2 circuits TRAE Dimensional Data...

Страница 27: ...SSC SVN001H EN 27 Fig 35 Dimensions Condensing Units TRAE 150 1 circuit TRAE Dimensional Data...

Страница 28: ...28 SSC SVN001H EN Fig 36 Dimensions Condensing Units TRAE 150 2 circuits TRAE Dimensional Data...

Страница 29: ...SSC SVN001H EN 29 Fig 37 Dimensions Condensing Units TRAE 200 1 Circuit TRAE Dimensional Data...

Страница 30: ...30 SSC SVN001H EN TRAE Dimensional Data Fig 38 Dimensions Condensing Units TRAE 200 2 Circuits...

Страница 31: ...SSC SVN001H EN 31 TRAE Dimensional Data Fig 39 Dimensions Condensing Units TRAE 250 1 Circuit...

Страница 32: ...32 SSC SVN001H EN TRAE Dimensional Data Fig 40 Dimensions Condensing Units TRAE 250 2 Circuits...

Страница 33: ...50 43 27 L2 L S2 S L1 S1 Power input on both side Modelo Cota 050 075 100 150 A 922 1146 1420 1640 B 1373 1474 1525 1829 C 560 560 560 560 D 341 341 290 341 E 374 480 402 432 F 386 386 326 386 G 230 2...

Страница 34: ...ion TRAE Suggestes clearances TRAE 050 to 150 Horizontal Discharge Fig 44 Suggested clearances TRAE 200 to 250 Vertical Discharge Fig 45 Suggested Clearances for Maintenance and Air Circulation Conden...

Страница 35: ...28 82 4 1 7 29 84 2 1 1 30 86 0 6 31 87 8 0 0 32 89 6 0 6 33 91 4 1 1 34 93 2 1 7 35 95 2 2 36 96 8 2 8 37 98 6 3 3 38 100 4 3 9 39 102 2 4 4 40 104 5 0 41 105 8 5 6 42 107 6 6 1 43 109 4 6 7 44 111 2...

Страница 36: ...ing safe comfortable and energy efficient environments Trane offers a broad portfolio of advanced controls and HVAC systems com prehensive building services and parts For more information visit www tr...

Отзывы: