background image

2

UNT-SVN009-EN

General Information

This Installation Manual is given as a
guide to good practice in the
installation by the installer of CFEB
chilled water fancoil system.
Installation procedures should be
performed in the sequence that they
appear in this manual.

For installing the unit to operate
properly and reliably, it must be
installed in accordance with these
instructions. Also, the services of a
qualified service technician should be
employed, through the maintenance
contract with a reputable service
company.

Read this Installation Manual
completely before installing the
air conditioning system.

About this Manual

Cautions appear at appropriate places
in this Installation Manual. Your
personal safety and the proper
operation of this machine require that
you follow them carefully.
The Trane Company assumes no
liability for installations or servicing
performed by unqualified personnel.
All phases of the installation of this air
conditioning system must conform to
all national, provincial, state and local
codes.

About the Unit

These CFEB units are assembled,
pressure tested, dehydrated and
run tested before shipment. The
information contained in this manual
applies to CFEB units are designed to
operate in cooling mode only and in
cooling or heating modes.

Trane CFEB series of chilled water
fancoil systems offer three styles of
installation: floor, low wall and under
ceiling with both LCD wireless remote
control or wired control. Trane CFEB
series provide flexibility and savings.

Note: 

For model CFEB 14, CFEB 16

and CFEB 20, there are only two styles
of installation: under ceiling and low
wall.

Reception

On arrival, inspect the unit before
signing the delivery note. Specify any
damage of the unit on the delivery
note, and send a registered letter of
protest to the last carrier of the goods
within 72 hours of delivery. Notify the
dealer at the same time.

The unit should be totally inspected
within 7 days of delivery. If any
concealed damage is discovered,
send a registered letter of protest to
the carrier within 7 days of delivery
and notify the dealer.

Warning

Warnings are provided at appropriate
places in this manual to indicate to
installers, operators and service
personnel of potentially hazardous
situations which, if not avoided,
COULD result in death or serious
injury.

Caution

Cautions are provided at appropriate
places in this manual to indicate to
installers, operators, and service
personnel of potentially hazardous
situations which, if not avoided, MAY
result in minor or moderate injury or
malfunction of the unit.

Your personal safety and the proper
operation of this unit require that you
follow them carefully.
The Trane Company assumes no
liability for installations or servicing
performed by unqualified personnel.

Warranty

Warranty is based on the general
terms and conditions by country. The
warranty is void if the equipment is
modified or repaired without the
written approval of
The Trane Company, if the perating
limits are exceeded or if the control
system or the electrical wiring is
modified.

Damage due to inappropriate
installation, lack of knowledge or
failure to comply with the
manufacturer’s instructions, is not
covered by the warranty obligation.
If the installation does not conform  to
the rules described in Installation
Manual, it may entail cancellation of
warranty and liabilities by
The Trane Company.

Important

This document is customer property
and is to remain with unit. Please
place in service information pack upon
completion of work.
These instructions do not cover all
variations in systems, nor do they
provide for every possible contingency
to be met in connection with
installation.
Should further information be desired
or should particular problems arise
which are not covered sufficiently in
this manual, the matter should be
referred to your Trane Sales
representative.

General Information

UNT-SVN009-EN.p65

9/9/09, 9:56 AM

2

Содержание AQUA NEW STYLUS CFEB 04 C0M1

Страница 1: ...Series 50 60 Hz 50 Hz Models Cooling Only CFEB 04 C0M1 CFEB 06 C0M1 CFEB 08 C0M1 CFEB 10 C0M1 CFEB 12 C0M1 CFEB 14 C0M1 CFEB 16 C0M1 CFEB 20 C0M1 60 Hz Models Cooling Only CFEB 04 C0M2 CFEB 06 C0M2 CF...

Страница 2: ...fy the dealer at the same time The unit should be totally inspected within 7 days of delivery If any concealed damage is discovered send a registered letter of protest to the carrier within 7 days of...

Страница 3: ...ation 5 Connection of Water Piping 6 Position of Piping Hole 6 Condensate Drain Piping 7 Electrical Installation 7 Remote Control Installation 8 Electronic Room Thermostat 9 Installation Typical Wirin...

Страница 4: ...be kept as short as possible Figure 1 6 Do not install unit in direct sunlight or near other heat sources as this may affect performance Do not allow outside air to directly enter unit or condensate...

Страница 5: ...nward 5 Pull air filters upward Figure 6 0 83 17 5 0 83 17 5 8 5 215 B A 6 Unscrew at the return grille Figure 7 7 Unscrew at the grille bottom hinges pull out the screw and unscrew at the side panel...

Страница 6: ...piping connections connect the female connections to the male adapter of the water piping connections at the inlet and outlet of the coil Then screw in and fasten the connections with an adjustable w...

Страница 7: ...iring Important Safeguards Check the unit nameplate for electrical rating Be sure wiring is done according to local codes and wiring diagram Connect electrical ground to all units Wiring should not to...

Страница 8: ...he remote control near heat sources or expose to the direct rays of the sun 2 Do not expose the control to the indoor unit s supply air stream 3 Do not place in a confined space 4 Attach the remote co...

Страница 9: ...ocated at or near the water drop or water mist Be careful not to leave any copper wire or piece of metal inside the control set Precaution This room thermostat is an electronic control device which re...

Страница 10: ...10 UNT SVN009 EN Typical Wiring Diagram WIRING DIAGRAM UNT SVN009 EN p65 9 9 09 9 57 AM 10...

Страница 11: ...11 UNT SVN009 EN Typical Wiring Diagram CFEB CHILLED WATER FANCOIL UNIT WITH WIRELESS CONTROL COOLING ONLY UNT SVN009 EN p65 9 9 09 9 57 AM 11...

Страница 12: ...12 UNT SVN009 EN CFEB CHILLED WATER FANCOIL UNIT WITH WIRED CONTROL COOLING ONLY Typical Wiring Diagram UNT SVN009 EN p65 9 9 09 9 57 AM 12...

Страница 13: ...0 0 59 627 1 24 71 A RUBBER ISOLATOR QTY C 254 3 10 02 359 1 14 15 74 2 2 93 234 3 9 23 RETURN AIR OUTLET CONNECTION INLET CONNECTION 610 7 24 06 123 1 215 0 143 6 DIMENSIONAL DATA 6 4 4 REV A 035 10...

Страница 14: ...6 RETURN AIR 234 3 9 23 74 2 2 93 OUTLET CONNECTION INLET CONNECTION 400 0 15 76 42 0 1 65 131 5 5 18 D 375 0 14 78 140 0 5 52 DIMENSIONAL DATA 8 8 REV B 035 1047 Sept 08 09 ECN NO 09114 09221 OUTLET...

Страница 15: ...15 UNT SVN009 EN Notes UNT SVN009 EN p65 9 9 09 9 57 AM 15...

Страница 16: ...Literature Order Number UNT SVN009 EN Date Sep 2009 Supersedes Apr 2008 Stocking Location Bangkok Thailand UNT SVN009 EN p65 9 9 09 9 57 AM 16...

Отзывы: