Performance Data Cooling
4YCY4048A1/3 AT 1600 NOM CFM
(COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
OD
ID
TOT
SENS CAP AT ENTERING DB TEMP
TOTAL
AMB
WB
CAP
72
75
78
80
KW
85
59
45.3
38.2
42.9
45.3
45.3
3.6
63
47.2
31.0
35.7
40.5
43.7
3.6
67
50.9
24.4
29.1
33.9
37.1
3.7
71
55.0
17.7
22.5
27.3
30.4
3.7
95
59
42.7
37.0
41.7
42.7
42.7
3.9
63
44.5
29.8
34.6
39.3
42.6
4.0
67
48.0
23.2
28.0
32.8
36.0
4.0
71
51.8
16.7
21.4
26.2
29.4
4.0
105
59
40.1
35.8
40.1
40.1
40.1
4.3
63
41.8
28.7
33.5
38.3
41.4
4.4
67
45.0
22.2
27.0
31.7
34.9
4.4
71
48.6
15.6
20.4
25.1
28.3
4.4
115
59
37.5
34.7
37.5
37.5
37.5
4.7
63
39.1
27.7
32.4
37.2
39.1
4.7
67
42.1
21.1
25.8
30.6
33.8
4.8
71
45.5
14.5
19.3
24.0
27.2
4.8
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW
CAPACITY
TOTAL POWER
RATE, CFM
MULTIPLIER
MULTIPLIER
LOW
1400
0.97
0.98
HIGH
1800
1.03
1.02
ARI RATING FOR COOLING
CFM
CAPACITY (A) TEST
SEER
EER
1605
48000
14.20
11.90
ARI Standard Capacity Rating Conditions
ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
4YCY4060A1/3 AT 2000 NOM CFM
(COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
OD
ID
TOT
SENS CAP AT ENTERING DB TEMP
TOTAL
AMB
WB
CAP
72
75
78
80
KW
85
59
56.5
47.6
53.5
56.5
56.5
4.4
63
58.9
38.5
44.5
50.5
54.4
4.4
67
63.5
30.2
36.2
42.2
46.2
4.5
71
68.5
21.9
27.8
33.8
37.8
4.5
95
59
53.1
46.0
52.0
53.1
53.1
4.8
63
55.4
37.0
43.1
49.0
53.0
4.9
67
59.7
28.8
34.8
40.7
44.8
5.0
71
64.4
20.5
26.4
32.4
36.4
5.0
105
59
49.7
44.5
49.7
49.7
49.7
5.3
63
51.9
35.7
41.6
47.6
51.6
5.3
67
55.9
27.4
33.3
39.3
43.3
5.4
71
60.3
19.1
25.0
31.0
35.0
5.4
115
59
46.4
43.0
46.4
46.4
46.4
5.8
63
48.3
34.2
40.2
46.2
48.3
5.8
67
52.1
26.0
32.0
37.9
41.9
5.9
71
56.2
17.7
23.7
29.6
33.7
5.9
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW
CAPACITY
TOTAL POWER
RATE, CFM
MULTIPLIER
MULTIPLIER
LOW
1750
0.97
0.98
HIGH
2250
1.03
1.02
ARI RATING FOR COOLING
CFM
CAPACITY (A) TEST
SEER
EER
1799
58500
14.00
11.90
ARI Standard Capacity Rating Conditions
ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
4YCY4042A1 AT 1400 NOM CFM
(COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
OD
ID
TOT
SENS CAP AT ENTERING DB TEMP
TOTAL
AMB
WB
CAP
72
75
78
80
KW
85
59
40.3
34.1
38.4
40.3
40.3
3.1
63
42.0
27.7
31.9
36.2
39.0
3.1
67
45.3
21.8
26.1
30.3
33.2
3.2
71
48.9
15.9
20.2
24.4
27.3
3.2
95
59
37.6
32.9
37.2
37.6
37.6
3.4
63
39.2
26.6
30.8
35.1
37.9
3.5
67
42.2
20.7
24.9
29.2
32.0
3.5
71
45.6
14.8
19.1
23.3
26.2
3.5
105
59
34.9
31.7
34.9
34.9
34.9
3.8
63
36.4
25.4
29.7
33.9
36.4
3.8
67
39.2
19.6
23.8
28.1
30.9
3.8
71
42.3
13.7
18.0
22.2
25.1
3.8
115
59
32.2
30.5
32.2
32.2
32.2
4.1
63
33.6
24.3
28.6
32.8
33.6
4.1
67
36.2
18.5
22.7
26.9
29.8
4.2
71
39.0
12.6
16.8
21.1
23.9
4.2
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW
CAPACITY
TOTAL POWER
RATE, CFM
MULTIPLIER
MULTIPLIER
LOW
1225
0.97
0.98
HIGH
1575
1.03
1.02
ARI RATING FOR COOLING
CFM
CAPACITY (A) TEST
SEER
EER
1360
42000
14.25
12.00
ARI Standard Capacity Rating Conditions
ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
Содержание 4YCY4024A
Страница 16: ...16 Typical Wiring ...
Страница 17: ...17 From Dwg 21D757165 P02 Typical Wiring ...
Страница 23: ...23 Dimensional Data 4YCY4024A through 4YCY4036A 1 of 3 ...
Страница 24: ...24 Dimensional Data 4YCY4024A through 4YCY4036A 2 of 3 ...
Страница 25: ...25 4YCY4024A through 4YCY4036A 3 of 3 Dimensional Data ...
Страница 26: ...26 Dimensional Data 4YCY4042A through 4YCY4060A 1 of 3 ...
Страница 27: ...27 Dimensional Data 4YCY4042A through 4YCY4060A 2 of 3 ...
Страница 28: ...28 4YCY4042A through 4YCY4060A 3 of 3 Dimensional Data ...