General .................................................................................1

Application Information ......................................................1

Recommendation ................................................................2

Furnace in Upflow Position ................................................2

Furnace in Downflow Position ...........................................2

Furnace in Horizontal Right Position.................................3

Furnace in Horizontal Left Position ...................................4

Maximum Airflow Setting (CFM) ........................................5

Installing / Brazing Refrigerant Lines ................................5

Leak Check  ..........................................................................5

Condensate Drain Piping ....................................................5

Cleaning the Coil .................................................................6

Outline Drawing ...................................................................7

Troubleshooting Indoor TXV / Cooling Mode ....................8

Installer’s Guide

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT — 

This Document is 

customer property

 and is to remain with this unit. Please return to service information pack 

upon completion of work.

IMPORTANT: Review your installation requirements. Check 

the table on the outline drawing and note all dimensions for 

your coil before beginning the installation.

Figure 1

18-AD42D1-1B-EN

Cased Aluminum "Convertible" Coil

Model:
4TXCB004DS3HCC
4TXCD010DS3HCC

NOTE: 

OPTIONAL DOWNFLOW GASKET INSTALLATION: For 

unusually humid applications that expect prolonged 

operation above 70% RH, it is recommended to use the 

BAYGSKT001A0 gasket kit to prevent water from forming 

on the bottom of the drain pan and dripping into the  

supply ductwork.

WARNING

!

This product can expose you to chemicals including 
lead, which are known to the State of California to case 
cancer and birth defects or other reproductive harm. 
For more information go to www. P65Warnings.ca.gov

A. GENERAL

This coil is designed for use in combination with a heat pump or 
cooling outdoor section using 

R-410A REFRIGERANT

The 4TXC equipment has been evaluated in accordance with 
the Code of Federal Regulations, Chapter XX, Part 3280 or 
the equivalent. “Suitable for Mobile Home use” The height of 
the Furnace, Coil and discharge duct work must be 7 ft. or less.

Inspect the coil for shipping damage. Notify the transportation 
company immediately if the coil is damaged.

B. APPLICATION INFORMATION

1.  FURNACE AND COIL 

The coil MUST BE installed downstream (in the outlet air) 
of the furnace. 

2.  INDOOR UNIT AIRFLOW 

Indoor unit must provide the required airflow for the heat 
pump or cooling combinations approved for this coil.

WARNING (Medium/high pressure) 

Contains Refrigerant!
System contains oil and refrigerant under high pressure. 
Recover refrigerant to relieve pressure before opening the 
system. See unit nameplate for refrigerant type. Do not 
use non-approved refrigerants, refrigerant substitutes, or 
refrigerant additives.
Failure to follow proper procedures or the use of non-
approved refrigerants, substitutes, or refrigerant additives 
could result in death, serious injury, or equipment damage.

WARNING

!

Содержание 4TXCB004DS3HCC

Страница 1: ...an expose you to chemicals including lead which are known to the State of California to case cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov A GEN...

Страница 2: ...out of the coil enclosure b Optional for maximum efficiency Remove the horizontal drain pan from the coil and discard 2 DOWNFLOW GASKET INSTALLATION OPTIONAL For unusually humid applications that expe...

Страница 3: ...out of the coil enclosure b When present remove the 2 outer water diverter baffles See Figure 2 2 Attach the coil and furnace in the orientation shown in Figure 6 For S Series furnaces bend flanges t...

Страница 4: ...l and slide back into the coil cabinet c Bend rear tab on top baffle inward towards the coil to avoid interference with splash guard See Figure 12 d Wedge flange of Splash Guard between Channel for Sp...

Страница 5: ...K CHECK 1 Using a manifold gauge connect an external supply of dry nitrogen to the gauge port on the liquid line 2 Pressurize the connecting lines and indoor coil to 150 PSIG maximum 3 Leak check braz...

Страница 6: ...refrigerant or condensate lines Once the outer doors are removed the inner coil panels can be easily removed The inside and outside of the coil can be easily cleaned withabrushandvacuumwiththepanelsr...

Страница 7: ...18 AD42D1 1B EN 7 Installer s Guide Outline Drawing for model 4TXCB004DS3HCC 4TXCD010DS3HCC From Dwg D346710 Rev A...

Страница 8: ...NO Is superheat 25F YES NO Is indoor temperature more than 85F NO Is sub cooling less than 8F YES Confirm that charge is correct and look for dirty or restricted outdoor coil Confirm that charge is co...

Страница 9: ...18 AD42D1 1B EN 9 Installer s Guide...

Страница 10: ...ications For more information please visit www trane com or www americanstandardair com The manufacturer has a policy of continuous data improvement and it reserves the right to change design and spec...