 18-AD42D1-1B-EN

Installer’s Guide

G. FURNACE IN HORIZONTAL LEFT POSITION 

CAUTION

!

Both the coil and furnace must be fully supported. Screws and 

standoffs are provided for alignment only.

Figure 11

AIRFLOW

FURNACE

DUCT

SPLASH

GUARD

CASED COIL

APEX OF COIL POINTS

AWAY 

FROM FURNACE

Figure 10

1.  HORIZONTAL LEFT COIL CONVERSION.  

While not required, optimal removal of some coil  

components will maximize airflow efficiency. 

 

a. Remove the coil by sliding the coil out of the coil  

    enclosure.  

b. If present, remove the (2) outer water diverter baffles.  

    See Figure 2.

2.  Splash Guard installation is required to prevent water 

blowoff.  

a. Place Channel for Splash Guard into Horizontal Drain  

    Pan as shown in Figure 9. 

b. Slide the new Horizontal Drain Pan onto the coil and  

    slide back into the coil cabinet.  

c. Bend rear tab on top baffle inward towards the coil to  

    avoid interference with splash guard. See Figure 12.  

d. Wedge flange of Splash Guard between Channel for  

    Splash Guard and Horizontal Drain Pan as shown in  

    Figure 11. 

e. Drive one field-supplied sheet metal screw into Splash  

    Guard through factory-provided clearance hole in the  

    front duct flange on the coil case. Refer to Figure 11. 

3.  Attach the coil and furnace in the orientation shown 

in Figure 10. For S-Series furnaces, bend flanges to 

accommodate installation as shown in Figure 5.  

4.  Insert standoffs into clearance holes in coil cabinet and 

use self-drilling screws to align coil and furnace. See 

Figure 3. Seal all gaps between the furnace and coil. 

NOTE:  

Screws and standoffs are for alignment only. Equipment 

must be fully supported when installed in horizontal.

Figure 12

BACK TAB IS BENT 

DOWNWARDS

SPLASH 

GUARD

Figure 9

CHANNEL

HORIZONTAL DRAIN PAN

Содержание 4TXCB004DS3HCC

Страница 1: ...an expose you to chemicals including lead which are known to the State of California to case cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov A GEN...

Страница 2: ...out of the coil enclosure b Optional for maximum efficiency Remove the horizontal drain pan from the coil and discard 2 DOWNFLOW GASKET INSTALLATION OPTIONAL For unusually humid applications that expe...

Страница 3: ...out of the coil enclosure b When present remove the 2 outer water diverter baffles See Figure 2 2 Attach the coil and furnace in the orientation shown in Figure 6 For S Series furnaces bend flanges t...

Страница 4: ...l and slide back into the coil cabinet c Bend rear tab on top baffle inward towards the coil to avoid interference with splash guard See Figure 12 d Wedge flange of Splash Guard between Channel for Sp...

Страница 5: ...K CHECK 1 Using a manifold gauge connect an external supply of dry nitrogen to the gauge port on the liquid line 2 Pressurize the connecting lines and indoor coil to 150 PSIG maximum 3 Leak check braz...

Страница 6: ...refrigerant or condensate lines Once the outer doors are removed the inner coil panels can be easily removed The inside and outside of the coil can be easily cleaned withabrushandvacuumwiththepanelsr...

Страница 7: ...18 AD42D1 1B EN 7 Installer s Guide Outline Drawing for model 4TXCB004DS3HCC 4TXCD010DS3HCC From Dwg D346710 Rev A...

Страница 8: ...NO Is superheat 25F YES NO Is indoor temperature more than 85F NO Is sub cooling less than 8F YES Confirm that charge is correct and look for dirty or restricted outdoor coil Confirm that charge is co...

Страница 9: ...18 AD42D1 1B EN 9 Installer s Guide...

Страница 10: ...ications For more information please visit www trane com or www americanstandardair com The manufacturer has a policy of continuous data improvement and it reserves the right to change design and spec...

Отзывы: