Installer’s Guide

4TWR3 & 4TWR4 OUTLINE DRAWING

NOTE: ALL DIMENSIONS ARE IN MM (INCHES).

From Dwg. D152898  Rev. 14

MODELS

BASE

FIG.

A

B

C

D

E

F

G

H

J

K

4TWR3018A

3

2

730 (28-3/4)

829 (32-5/8)

756 (29-3/4)

1/2

1/4

127 (5)

76 (3)

197 (7-3/4)

57 (2-1/4)

508 (20)

4TWR3024A

3

2

730 (28-3/4)

829 (32-5/8)

756 (29-3/4)

5/8

5/16

127 (5)

76 (3)

197 (7-3/4)

57 (2-1/4)

508 (20)

4TWR3030A

3

2

933 (36-3/4)

829 (32-5/8)

756 (29-3/4)

3/4

5/16

143 (5-5/8)

92 (3-5/8)

210 (8-1/4)

79 (3-1/8)

508 (20)

4TWR3036A

4

1

943 (37-1/8)

946 (37-1/4)

870 (34-1/4)

3/4

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)

86 (3-3/8)

508 (20)

4TWR3042A

4

1

943 (37-1/8)

946 (37-1/4)

870 (34-1/4)

3/4

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)

86 (3-3/8)

508 (20)

4TWR3048A

4

1

1045 (41-1/8)

946 (37-1/4)

870 (34-1/4)

7/8

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)

86 (3-3/8)

508 (20)

4TWR3060A

4

1

1045 (41-1/8)

946 (37-1/4)

870 (34-1/4)

7/8

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)

86 (3-3/8)

508 (20)

4TWR4018A

3

1

933 (36-3/4)

829 (32-5/8)

756 (29-3/4)

1/2

1/4

143 (5-5/8)

92 (3-5/8)

210 (8-1/4)

79 (3-1/8)

508 (20)

4TWR4024A

3

1

1035 (40-3/4)

829 (32-5/8)

756 (29-3/4)

5/8

5/16

143 (5-5/8)

92 (3-5/8)

210 (8-1/4)

79 (3-1/8)

508 (20)

4TWR4030A

3

1

1035 (40-3/4)

829 (32-5/8)

756 (29-3/4)

3/4

5/16

143 (5-5/8)

92 (3-5/8)

210 (8-1/4)

79 (3-1/8)

508 (20)

4TWR4036A

4

1

943 (37-1/8)

946 (37-1/4)

870 (34-1/4)

3/4

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)

86 (3-3/8)

508 (20)

4TWR4042A

4

1

1045 (41-1/8)

946 (37-1/4)

870 (34-1/4)

3/4

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)

86 (3-3/8)

508 (20)

4TWR4048A

4

1

1045 (41-1/8)

946 (37-1/4)

870 (34-1/4)

7/8

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)

86 (3-3/8)

508 (20)

4TWR4060A

4

1

1045 (41-1/8)

946 (37-1/4)

870 (34-1/4)

7/8

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)

86 (3-3/8)

508 (20)

Содержание 4TWR3

Страница 1: ...use by individuals posses sing adequate backgrounds of electrical and mechanical experience Any attempt to repair a central air conditioning product may result in personal injury and or property dama...

Страница 2: ...should not exceed sixty 60 feet liquid line 8 Locate and install indoor coil or air handler in accordance with instruction included with that unit C INSTALLING REFRIGERANT LINES CAUTION If using exist...

Страница 3: ...indoor units is completed the field brazed connections must be checked for leaks Pressurize through the service valve ports the indoor unit and field refrigerant lines with dry nitrogen to 350 400 ps...

Страница 4: ...te and relative capacity of the heat pump system By measuring the change in delta T we can determine the need for defrost The coil sensor also serves to sense outdoor coil temperature for termination...

Страница 5: ...E W IR IN G C O M P R E S S O R IO L R U N C A P A C IT O R S T A R T C A P A C IT O R S T A R T R E L A Y C O N T A C T O R C O N T A C T S L O W V O L T A G E W IR IN G C O N T R O L T R A N S F O R...

Страница 6: ...Subcool Charging Table Pressure 20 15 Use Design Subcool Value from Table 10 0 Subtract 10 psig from S C Table Pressure 10 20 25 30 40 60 80 TOTAL REFRIGERANT LINE LENGTH FEET REFRIGERANT LINE LIFT FE...

Страница 7: ...946 37 1 4 870 34 1 4 7 8 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 508 20 4TWR3060A 4 1 1045 41 1 8 946 37 1 4 870 34 1 4 7 8 3 8 152 6 98 3 7 8 219 8 5 8 86 3 3 8 508 20 4TWR4018A 3 1 933 36 3 4 829 32...

Страница 8: ...nry been sealed If mortar is used prevent mortar from coming into direct contact with copper tubing 5 Verify tightness of all electrical connects 6 Observe outdoor fan during on cycle for clearance an...