Trane 4NXCA018AC3HCA Скачать руководство пользователя страница 1

Installer’s Guide

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT — 
This Document is customer property and is to remain with this unit.  Please return to service informa-

tion pack upon completion of work.

4NXCA018AC3HCA
4NXCA024AC3HCA
4NXCB025AC3HCA
4NXCB031AC3HCA

WARNING

!

WARNING (Medium/high pressure)
Contains Refrigerant!
System contains oil and refrigerant under high pres-
sure.  Recover refrigerant to relieve  pressure before 
opening the system.  See unit nameplate for refrigerant 
type.  Do not use non-approved refrigerants, refriger-
ant substitutes, or refrigerant additives.
Failure to follow proper procedures or the use of 
non-approved refrigerants, substitutes, or refriger-
ant additives could result in death, serious injury, or 
equipment damage.

NOTE: 

The 4NXCB025AC3HCA and the 4NXCB031AC3HCA coils 

are not direct replacements for previously installed 4TXC 

coils.  There is a height difference in the two coils models 

between the two coil families.

A.  GENERAL
These coils are designed for use in combination with a heat 
pump or cooling outdoor section using 

R-410A REFRIGER-

ANT

.  These coils may be converted for use with a horizontal 

furnace as well.
The 4NXC equipment has been evaluated in accordance with 
the Code of Federal Regulations, Chapter XX, Part 3280 or the 
equivalent. “Suitable for Mobile Home use” The height of the 
Furnace, Coil and discharge duct work must be 7 ft. or less.
Inspect the coil for shipping damaged.  Notify the transporta-
tion company immediately if the coil is damaged.
B.  APPLICATION INFORMATION
1. FURNACE AND COIL
The coil MUST BE installed downstream (in the outlet air) 
of the furnace.  The coil apex can face into or away from the 
direction of the airflow, depending on horizontal left or right 
application.

A341869P25

These coils fit the 17½" and 24½" width furnaces without 
any adapters in vertical upflow, downflow, or horizontal ap-
plication.  

Some coils require model specific changes 

to the coil.  See application specific sections. 
2. INDOOR UNIT AIRFLOW
Indoor unit must provide the required airflow for the heat 
pump or cooling combinations approved for these coils.

IMPORTANT: Review your installation requirements.  Check 
the table on the outline drawings and note all dimensions 
for your coil before beginning the installation.

Table of Contents

General ............................................................................... 1

Application Information ................................................ 1

Recommendation ............................................................. 1

Furnace in Upflow Position .......................................... 2

Furnace in Downflow Position ..................................... 3

Furnace in Horizontal Left Position ........................... 4

Furnace in Horizontal Right Position ........................ 6

Maximum Airflow Setting, CFM ................................... 7

Installing Refrigerant Lines ......................................... 7

Field Fabricated Interconnecting Lines .................... 7

Brazing to Evaporator .................................................... 7

Leak Check........................................................................ 8

Condensate Drain Piping .............................................. 8

Cleaning the Coil ............................................................. 8

Outline Drawings ............................................................ 9

Replacing TXC***S3 Coil with NXC***C3 Coil ........11

TXV Change Out .............................................................11

Figure 1

18-AD28D1-2

Cased Aluminum "Convertible" Coils

4NXCB032AC3HCA
4NXCB036AC3HCA
4NXCD063BC3HCA

Содержание 4NXCA018AC3HCA

Страница 1: ...ile Home use The height of the Furnace Coil and discharge duct work must be 7 ft or less Inspect the coil for shipping damaged Notify the transporta tion company immediately if the coil is damaged B A...

Страница 2: ...ews See Figure 2 b Replace only the top baffle using the same screws previously removed c The 2 outer water diverter baffles and the two piece factory baffle must be removed and the top baffle replace...

Страница 3: ...same screws previously removed c Installation of the 1 2 wide gasket behind the front and back triangular baffles is required for downflow ap plications d Remove the coil by sliding the coil out of t...

Страница 4: ...ombustible flooring a Place the coil case on the furnace supply air ple num b Secure the coil case to the plenum c Set the furnace on top of the coil case making sure that the back side of the dischar...

Страница 5: ...brackets for coil furnace alignment are included with the furnaces a In horizontal left the 4NXC coil case is rotated so the apex of the coil is away from the furnace and the auxiliary drain pan is no...

Страница 6: ...rflow for horizontal right installation This placement supersedes previous furnace Installer s Guide stating install with the apex of the coil pointing in the direction of airflow for horizontal appli...

Страница 7: ...ANT LINES 1 The following steps are to be considered when installing the refrigerant lines a Determine the most practical way to run the lines b Consider types of bends to be made and space limita tio...

Страница 8: ...he drain line to prevent sweating and dripping It is always recommended that an auxiliary drain pan be in stalled under a horizontally installed evaporator coil or 90 gas furnace Connect the auxiliary...

Страница 9: ...2 18 1 4 22 1 2 OVERALL WIDTH B IN 14 1 2 17 1 2 17 1 2 OPENING WIDTH C IN 13 5 8 16 5 8 16 5 8 TOP OPENING D 12 3 4 15 3 4 15 3 4 GAS CONNECTION 3 4 BRAZE LIQUID CONNECTION 3 8 BRAZE MATCHED FURNACE...

Страница 10: ...ARY DRAIN 3 4 NPT FOR VERTICAL POSITION PRIMARY DRAIN 3 4 NPT FOR VERTICAL POSITION 18 1 8 OPENING IN WRAPPER 21 1 2 3 1 8 7 8 19 3 8 MODEL 4NXCD063BC3HCA WEIGHT LBS 80 REFRIGERANT CONTROL TXV NON BLE...

Страница 11: ...the refrigerant system 17 Charge the system per the charging instructions with the outdoor unit P TXV CHANGE OUT 1 Unbraze the liquid line field connection 2 Remove the front panel and manifold panel...

Страница 12: ...decrease Measure superheat at indoor coil while placing the bulb in an ice and water bath for one minute Does superheat increase YES Replace the TXV NO TXV is OK NO Is superheat 20F NO YES NO Is indoo...

Отзывы: