TK 56702-1-OP-EN
93
Important:
Only OAT extended life coolants (Chevron Delo® XLC or equivalent) should be
added to Thermo King systems. Conventional coolants should not be used
(Typically identified by green or blue-green color). If a conventional coolant is
combined with the Thermo King factory fill up to 25% by volume, the coolant
must be changed at the next service opportunity. Above 25%, the coolant
must be changed immediately. Conventional coolants dilute/interact with the
additive packages of extended life coolant which significantly reduces the
service life of the coolant.
Engine
Thermostat
160 F (71 C)
Coolant
Expansion Tank
Cap Pressure
10 psig (69 kPa)
Refrigeration System
Contact your Thermo King dealer for refrigeration service or maintenance.
Electrical Control System Specifications
Control System Voltage
12.5 Vdc
Battery Charging System
12 volt, 37 amp, brush type, Thermo
King Alternator
Voltage Regulator Setting
13.4 to 14.5 volts
Fuses
Fuse
Size
Function
F2
15A
Power to On/Off Switch
F3
40A
Fuel Sol Pull-In/Starter Circuit
F4
None
No Fuse
F5
40A
Preheat Circuit
F6
15A
Damper and High Speed Circuits
F7
2A
8XP Circuit - Controller On Feedback to HMI
F8
5A
2A Power to CAN Connector J12
F9
5A
2A Power to CAN Connector J14