68
TK 56702-1-OP-EN
If enabled in Guarded Access, Sleep Mode is used to keep the engine
warm and the battery charged when the unit is not in use. When the
unit is in Sleep Mode, the display will show "SLEEP" and the current
time. When Sleep Mode is entered, the unit will start and run to
confirm proper battery charge level and engine temperature.
IIm
mp
po
orrtta
an
ntt:: While in Sleep Mode, the unit will not monitor or maintain
setpoint and load temperature. Fuel level should be
monitored as the unit may run periodically, particularly in
cold weather.
The following features are available in Sleep Mode:
–
P
Prro
og
grra
am
m W
Wa
akke
eu
up
p T
Tiim
me
e:: This feature allows a wakeup time to be
specified. When the selected time is reached the unit will start and
resume normal operation. If a Wakeup Time is selected, the
following features are available:
•
D
Da
ay
y tto
o W
Wa
akke
e U
Up
p:: This feature allows the day of the week the
unit is to wake up to be specified.
•
H
Ho
ou
urr tto
o W
Wa
akke
e U
Up
p:: This feature allows the hour the unit is to
wake up to be specified.
•
M
Miin
nu
utte
e tto
o W
Wa
akke
e U
Up
p:: This feature allows the minute the unit is
to wake up to be specified.
•
R
Ru
un
n P
Prre
ettrriip
p o
on
n W
Wa
akke
eu
up
p:: This feature allows a Pretrip Test to
be automatically run when the unit wakes up.
Mode changes are made using the Mode Menu. From the Standard Display,
press the MENU key.
Figure 76.
Menu Key
The Language Menu or Alarm Menu will appear. Press the NEXT key as
required to show the Mode Menu. When the Mode Menu is shown, press the
SELECT key.