background image

TEF 9964

  

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

INSTALLATION INSTRUCTIONS

The floodlight should be installed according to the 

calculated light distribution plan. 

1.

The glass in front should 

face the centre at the 

helideck, unless stated 

otherwise.

2.

Secure the floodlight to 

the helideck by means 

of four M10 bolts.

3.

Open the enclosure cover 

on rear. Replace cable 

gland gaskets as 

required to match the cable 

diameter. Unused cable 

glands should always 

be replaced with a blind plug.

4.

Connect cables and 

replace the enclosure cover.

DIMENSIONS

5.

Luminaire housing shall be connected to earth potential by groundwire of min. crossection 2,5mm² / 14AWG

996A106032

Содержание TEF 9964 Helideck

Страница 1: ...way T 47 51 57 89 00 F 47 51 57 89 50 Office Oslo Luhrtoppen 2 N 1470 Lørenskog Norway T 47 24 08 44 10 IMPORTANT Read this instruction carefully before installing the product LIGHTING TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY SAFE AREA USER MANUAL Subject to change without prior notice TUM1024 REV L 26 01 2022 ...

Страница 2: ...wdriver for open closing the cover of the junction box 3 mm flat screwdriver for installing the cable in the terminal block 5 5 mm flat screwdriver for removing the lamp insert 32 mm wrench to assembly the cable gland 30 mm wrench to tighten the lock nut and the pressure nut MAINTENANCE INSTRUCTIONS The luminaire should be inspected according to Company routines The manufacturer suggests regular c...

Страница 3: ...unless stated otherwise 2 Secure the floodlight to the helideck by means of four M10 bolts 3 Open the enclosure cover on rear Replace cable gland gaskets as required to match the cable diameter Unused cable glands should always be replaced with a blind plug 4 Connect cables and replace the enclosure cover DIMENSIONS 5 Luminaire housing shall be connected to earth potential by groundwire of min cro...

Страница 4: ...Loosen clamps and remove front ring Warning High voltage components inside lamp Make sure to disconnect power before opening Distance bracket Distance bracket Holding clip Old version 2 REMOVE HOLDING CLIP AND OR DISTANCE BRACKET 1 REMOVE FRONT RING 3 SLIDE OUT LAMP INSERT New version ...

Страница 5: ...ng ring 4b 1 Disassemble the reflector unit 3 x M4 screws Disconnect the hight voltage plug 4b 2 Position lamp removal tool over locking ring as shown below Twist approx 30 degrees anti clockwise 4b 3 Remove xenon lamp Locking ring Xenon lamp 4A REMOVE LIGHT BULB NEW VERSION 4B REMOVE LIGHT BULB OLD VER Note make sure the new xenon bulb is clean Do not touch the glass part of the bulb Mount lamp b...

Страница 6: ...IP rating with drain plug IP 66 Cable glands 2 X M25 E204 622 M25 D kit Cable diam 11 0 15 0 mm 15 0 20 1 mm Area of use Safe area Weight 10 kg SPARE PARTS Part No Xenon Lamp D2S 35W For TEF 9964 9400074 Front Glass 3241 High Voltage Igniter Unit Xenon 9400103 Locknut for Xenon D2S 9400108 Transformer W Mounting Bracket for 9964 230 254 VAC 4386 Transformer W Mounting Bracket for 9964 110 VAC 4387...