4a-1:
Disconnect the high voltage plug from the light bulb.
Position lamp removal tool over locking ring as shown
below. twist approx. 30 degrees anti-clockwise.
4a-2:
Remove xenon lamp
Xenon lamp
Locking ring
4b-1:
Disassemble the reflector unit. 3 x M4 screws
Disconnect the hight voltage plug.
4b-2:
Position lamp removal tool over locking ring as shown
below. Twist approx. 30 degrees anti-clockwise.
4b-3:
Remove xenon lamp
Locking ring
Xenon lamp
4A. REMOVE LIGHT BULB, NEW VERSION
4B. REMOVE LIGHT BULB, OLD VER-
Note: make sure the new xenon bulb is clean. Do not touch the glass part of the bulb.
Mount lamp back together in reversed order.
5. INSERT NEW XENON BULB